Indication Item Output *1 Circulating fluid discharge temperature 0 to 100:010V (1) Analog Analog output Output 1 signal 1 *2 Circulating fluid 0.150.0S/cm: 0.0210.0V electric conductivity *1 Circulating fluid discharge temperature 0 to 100:010V (2) Analog Analog output Output 2 signal 2 *2 Circulating fluid 0.1 to 50.0S/cm: 0.0210.0V electric conductivity *1 By default *2 For option D With
T NPTF Coil rated Electrical entry 3 8 G F 1 100 VAC, 50/60 Hz Grommet Nil T Conduit terminal Standard 4 1 2 Option 2 200 VAC, 50/60 Hz Port size Manual override P None Nil Option WTB Dripproof conduit terminal 3 110 VAC, 50/60 Hz 1 4 Rc 3 8 Rc 1 2 Rc 3 4 Rc 02 03 04 06 TZ Conduit terminal w/ surge voltage suppressor 4 220 VAC, 50/60 Hz How to Calculate the Flow Rate 5 24 VDC 9 Other TL
Series VXF How to Order VXF 2150 06 1 G Solenoid type Normally closed VXFA 2150 06 Air operated type Option Nil S Standard With silencer Refer to the table (2) below for availability.
Japanese N ...North American No Of Needle Revolutions 10 Turns / 8 Turns (AS1001F) Applicable Tube Material Nylon, Soft Nylon, Polyurethane A P P L I C A B L E T U B E OD B O D Y S I Z E mm 23 32 04 4 06 6 08 8 10 10 12 12 Inch 01 1/8 03 5/32 05 3/16 07 1/4 09 5/16 11 3/8 13 1/2 100 ...M5 (04, 06) 200 ...1/8 (04, 06) 205 ...1/4 (06, 08) 300 ...3/8 (06, 08, 10, 12) 400 ...1/2 (10, 12) W I
AL10, 20 AL30, 40, 40-06 AL50, 60 1 8 Body Zinc die-cast Aluminum die-cast Platinum silver Housing Platinum silver Aluminum die-cast Replacement parts Part no. Material Description No.
Inch size ARJ310F-N01 5/32" 1/4" 03 07 674 Miniature Regulator ARJ310 Series Flow Rate Characteristics (Representative Values) Inlet pressure: 0.7 MPa ARJ310-01 ARJ310F-01-04 ARJ310F-01-06 0.7 0.7 0.7 0.6 0.6 0.6 Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) ARJ ARJ 0.5 0.5 0.5 AR425 to 935 0.4 0.4 0.4 0.3 0.3 0.3 ARX 0.2 0.2 0.2 AMR 0.1 0.1 0.1 ARM 0.0 0.0 0.0 0 100 200
0.7 0.7 0.7 0.6 0.6 0.6 Downstream pressure MPa Downstream pressure MPa Downstream pressure MPa 0.5 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0 100 200 300 400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Pressure Characteristics Conditions: Upstream pressure 0.7MPa Downstream pressure
0.7 0.7 0.7 0.6 0.6 0.6 Downstream pressure MPa Downstream pressure MPa Downstream pressure MPa 0.5 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0 100 200 300 400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Pressure Characteristics Conditions: Upstream pressure 0.7MPa Downstream pressure
SY SYJ VK Blank plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 VZ L Dimensions VT A One-touch fitting d Part No. A L D VT KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 D VP Color: White VG VP L DIN rail AXT100-DR-l 12.5 (Pitch) 5.25 7.5 VQ Enter suffix number into l from the table below.
ZF ZP ZCU How to Order Ejector Manifold AMJ ZZMA 06 06 R Misc. Number of stations Port and silencer location R L B 01 1 station Right side Left side Both sides 10 10 stations (max.) Note) Right and left side are viewed from the front side of VAC port.
Recommended speed controller Model Elbow type 10-AS2201F-01-06-X214 10-AS2201F-02-06-X214 10-AS2201F-02-06-X214 10-AS3201F-02-08-X214 10-AS3201F-02-08-X214 Model Straight type 10-AS2301F-01-06-X214 10-AS2301F-02-06-X214 10-AS2301F-02-06-X214 10-AS3301F-02-08-X214 10-AS3301F-02-08-X214 In-line type 10-AS2001F-06-X214 10-AS2001F-06-X214 10-AS2001F-06-X214 10-AS3001F-08-X214 10-AS3001F-08-X214
Example) AR30K-03BE-1NR-B w e V q Body size 20 25 30 40 50 60 Symbol Description V w With backflow function Nil Without backflow function K Note 1) With backflow function + V e Pipe thread type Nil Rc N NPT F G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 V r Port size + a Mounting Nil Without mounting option B Note 3) With bracket H With set nut (for panel mount) + Nil Without pressure
Model Elbow type Straight type In-line type 12-REA25 10-AS2001F-06-X214 10-AS2201F-01-06-X214 10-AS2301F-01-06-X214 12-REA32 10-AS2001F-06-X214 10-AS2201F-02-06-X214 10-AS2301F-02-06-X214 6. Do not use the cylinder with its body fixed. Be sure to secure both head covers (or end covers in case of CY1R) before using the cylinder.
How to Order VR 12 1 06 0 F Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 2 1/8 standard 1/4 standard 23 04 06 08 10 01 03 07 09 11 3.2 4 6 8 10 1/8" 5/32" 1/4" 5/16" 3/8" With One-touch fitting Use 1/8" tubing for 3.2. 1 Series VR120F Application Circuit Examples Self holding circuit 1. When "A" is turned ON, output goes ON. 2.
How to Order VR 12 1 1 F 06 Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 1/8 standard 3.2 23 04 06 01 03 07 1/8" 5/32" 1/4" 4 6 Use 1/8" tubing for 3.2.
Connector part no.: VK300-82-1 Part no. of connector with light Rated voltage Voltage symbol 100 VAC 100V Part no. VK300-82-2-01 VK300-82-2-03 110 VAC 110V 200 VAC 200V VK300-82-2-02 VK300-82-2-04 220 VAC 220V VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 240 VAC 240V 6 VDC 6V 12 VDC 12V 24 VDC 24VD 48 VDC 48VD 3-2-11
VK300-82-2-01 100 VAC V100 VK300-82-2-03 110V 110 VAC 200 VAC 220 VAC VK300-82-2-02 200V VK300-82-2-04 220V S070 240V 6V 12V 24VD 48VD 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 DIN terminal VQD VQD-V Light (Built-in connector) Marking Circuit with light AC Circuit diagram 12 VDC or less Circuit diagram 24 VDC or more Circuit
To send request messages in series, wait for 100 msec. or longer after receiving a response message from the product before sending the next message. Retry (resend request message). The response may not be returned due to noise. If no message is returned 1sec. after sending a request message, resend the request message.
rate (l/min (ANR)) 1.5 3 6 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 07, 08, 09, 10, 11 Effective area (mm2) Effective area (mm2) Effective area (mm2) 300 06 1.0 2 4 200 50 100 0.5 1 2 100 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations ASD530F ASD630F 1500 1000 14 Flow rate (l/min (ANR)) 20 Flow rate (l/min (ANR)) 10,11 12
AS121FM-M5-23 AS121FM-M5-04 AS121FM-M5-06 AS221FM-01-23 AS221FM-01-04 AS221FM-01-06 AS221FM-01-08 AS221FM-02-04 AS221FM-02-06 AS221FM-02-08 AS221FM-02-10 3.2 4 6 3.2 4 6 8 4 6 8 10 22.1 22.1 22.9 27.5 27.5 27.5 32.4 34.4 34.4 36.4 43.2 8.4 9.3 11.6 9.3 9.3 11.6 15.2 10.4 12.8 15.2 18.5 17.3 17.3 18.1 20.4 20.4 20.4 25.3 25.2 25.2 27.2 33.9 12.7 12.3 7 28.8 25.1 30.1 9.6 33.8 M5 x 0.8 8 13.5