SMC Corporation of America
Elite Part Number Search
Search Results "FH342-06-500-M020X0"

600 200 VXB215 C F(H) 100 300 400 500 600 700 800 200 Flow rate Q [kg/h] How to read the graph The sonic range pressure to generate a flow rate of 300 kg/h is P1 0.3 MPa for the VXB215C F(H).

AMF250 AMF350 AMF450 AMF550 AMF650 AMF850 AMF150 Model Note) 500 1000 2000 3500 6000 12000 200 Rated flow (l/min (ANR)) Port size (Nominal size B) , , , , , , , , , 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 , , 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Weight (kg) Note) Max. flow capacity at a pressure of 0.7 MPa. Max. flow varies depending on operating pressure.

Conventional system> Series AM Series AMD Series AMH ( Prefilter) + ' Filtration rating . 0.3 I' m 0.01 I'm 0.3+0.01 I'm Oil misl removal rate : O.8ppm (1.0mglm3(ANR)} O .08ppm (O.1 mg/m3(ANR)) 008ppm (O.1 mglm3(ANR)) Micro-Mist Separator with Prefilter Micro-Mist Separator SeriesAMH Available Models Model AMH150 AMH250 AMH350 AMH450 AMH550 AMH650 AMH850 Air flow rate NOle) Q/min (ANR) 200 500

Calculating motor speed conversion example using an actuator with a 20mm lead and 500[mm/sec] speed.

Calculating motor speed conversion example using an actuator with a 20mm lead and 500[mm/sec] speed.

Switch output Pressure Set Pressure: ON Pressure Set Pressure: ON 500 kPa Max. operating pressure 1 MPa Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.

2)C (3)B180 (1) (2) (3) A B C (EX600-ZT1) -15No.EX-OMN0027CN-D SI EX600-S A SI 1 PNP(-COM) 2 NPN(+COM) PR PROFIBUS DP No. 1 LED 2 3 4 (BUS OUT) 5 6 (PCI) 7 8 9 10 11 (BUS IN) 12 (2 ) (BUS OUTPCI) -16No.EX-OMN0027CN-D BUS IN BUS OUT 1 NC 2 RXD/TXD-N 3 NC 4 RXD/TXD-P 5 Shield T PROFIBUS DP BUS OUT SI IP67 PROFIBUS DP A [kbps] 9.6 19.2 45.45 93.75 187.5 500

kPa) Within 60kPa (@ Set Pressure 500 700 kPa) Repeatability 20 kPa Weight 0.15kg Port/Connection Rc(PT)1/4 Flange Rc(PT) 1/4 Flange Micro Switch Type Standard Microload Minimum Applicable Load DC 5V 160mA DC 5V 1mA 1KPa = 0.145PSI W I R I N G Please wire micro-switch in accordance with the molded symbols that appear beside the terminal screws.

PEND Specifications Water/Non-corrosive liquid Fluid 0.1 to 0.6 MPa Operating pressure Water resistance 1.2 MPa 5 to 60C (No freezing) Operating temperature range Operation Diaphragm style 100 M (500 DC by megameter) Insulation resistance Withstand voltage 1500 VAC for one min.

Between external terminals and case 2 M (500 VDC by megameter) Insulation resistance Between external terminals and case 1000 VAC 50/60 Hz for 1 min. Pressure Switch Calibration Withstand voltage 10 to 500 Hz Pulse width 1.5 mm or acceleration 98 m/s2 (at the smaller vibration) in X, Y, Z directions (2 hours) Vibration resistance Use the calibration adjustment to set ON pressure.

B (9.5) B (12.7) B (19.1) B (25.4) B (31.8) B (38.1) B (50.8) VNA 111 211 311 411 511 611 711 AS 420-03 420-04 500-06 600-10 800-12 900-14 900-20 3 8 1 2 3 4 10A 15A 20A 25A 32A 40A 50A 1 2 VNA01 VNA02 VNA03 VNA1 Port 12 (P1) 1 1 1 2 External pilot External pilot External pilot External pilot External pilot Pilot exhaust Bleed port Bleed port 1 4 1 2 10 (P2) Installing a silencer to the

NPT ZQ 06 3/4 10 1 ZF ZP Nil 2 6 J R Option/Combinations Combination available Combination not available ZCU Option Symbol Drain cock Nil AMJ Metal bow 2 Nylon bowl Misc. 6 Drain guide J Flow: Right Left R Model Model AMJ5000 AMJ4000 AMJ3000 Recommended flow rate (l/min(ANR)) 500 300 200 Port size (Nominal size B) 3/4, 1 3/8, 1/2 1/4, 3/8 Weight (kg) 1.1 0.6 0.3 Specifications Fluid Air

In an application where the set point P1 is at 500[mmHg] and second setpoint P3 is set at 600[mmHg] every time the generated vacuum goes below 600[mmHg] a counter records the intance. If the counter reaches a preset limit, the failure predict output becomes energized signaling a potential problem, even though normal operation of the process has not yet been compromised.

A( ) A 24V 12V 100V SY100-82-3-05 SY100-82-3-06 SY100-82-2-01 24V DC 12V DC 100V AC SOL SOL C(+) C ZNR Light DIN connector circuit with light AC circuit DC circuit 1 2 1 2 NL R R LED NL: Neon light R: Resistor LED: Emitting diode R: Resistor 4.3-2 Series VQ20/30 Manifold Caution Caution Valve Mounting How to Mount/Remove from DIN Rail After confirming the gasket is correctly placed under

XT53440 05 Number of stations 05 06 12 1 station 2 station 8 station 13-9-10

FH series suction filters are compact and lightweight. Designed with an aluminum casted housing. Element can be replaced by simply opening the cover to detach the element without touching the pipes. The filter can be fitted with a differential pressure indicator which senses when the element is becoming dirty, facilitating maintenance and helping to avoid pump damage such as cavitations.

FH series suction filters are compact and lightweight. Designed with an aluminum casted housing. Element can be replaced by simply opening the cover to detach the element without touching the pipes. The filter can be fitted with a differential pressure indicator which senses when the element is becoming dirty, facilitating maintenance and helping to avoid pump damage such as cavitations.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, IN-LINE FILTER, OTHERS, FHG HYDRAULIC FILTER, GX, FHG 3/4INCH (MISC./OTHER), 6.25823 lb

FH series suction filters are compact and lightweight. Designed with an aluminum casted housing. Element can be replaced by simply opening the cover to detach the element without touching the pipes. The filter can be fitted with a differential pressure indicator which senses when the element is becoming dirty, facilitating maintenance and helping to avoid pump damage such as cavitations.

Material: T (SCS14 Cover, SS 316 Case, Fluororesin Gasket/O-ring, Fluororesin Seal), Element Length: B [ℓ500 (ℓ250 x 2)], Port Size: 06 (3/4 Rc), Element Type: P (Paper, Cotton Material), Nominal Filtration Accuracy: 20 μm, Element Seal Material: N (NBR), Accessory: None, Made to Order: X78 (Differential Pressure Indication Switch)