[MPa] Circulating fluid pressure [MPa] Usable flow rate range Usable flow rate range 0.5 0.5 50 HECR 50 0.43 0.45 Outlet Pump head [m] Pump head [m] Outlet 0.4 0.4 40 40 HEC 0.3 30 0.3 30 HEB 0.2 20 0.2 20 HED Return port 0.1 10 0.1 10 Return port 0 0 0 0 HEA 45 40 50 0 10 20 30 60 70 80 90 100 110 120 Circulating fluid flow rate [L/min] 45 0 20 10 40 30 50 60 70 80 90 100 110 120 130 Circulating
A water-resistant type cylinder is recommended for use in an environment which requires water resistance. 2 The 1 m lead wire is only applicable to the D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 3 m L (Example) M9NWL 1 m M (Example) M9NWM 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.
LC (Knock pin position) W Y M X LX LZ Z LS + Stroke ZZ + 2 Stroke 4-LD (mm) 7 7 6 6 LD 4 4 4 4 LC 30 25 22 20 LH 16.5 16 15 15 X 60 69 69 69 LS 4 3.5 3.5 3 M 3 3 3 3 LT B 8.5 8 7 7 Y 10 10 10 10 W 54 44 36 32 LX 187 175 173 163 ZZ 71 58 49 44 LZ Z Bore size 63.5 53 52 47 54.5 45 38.5 34 40 32 25 20 10 12 55 74 4.5 100 125 5 20 28.5 80 101 6 11 65 74 6 120 150 7 20 30 100 121 6 14 With air
Specifications LAT3-10 Stroke 10 mm, Resolution 30 m LAT3-20 Stroke 20 mm, Resolution 30 m Card Motor 8 options LAT3-30 Stroke 30 mm, Resolution 30 m (Refer to the table Product LAT3M-50 Stroke 50 mm, Resolution 5 m Number on the right) LAT3F-10 Stroke 10 mm, Resolution 1.25 m LAT3F-20 Stroke 20 mm, Resolution 1.25 m LAT3F-30 Stroke 30 mm, Resolution 1.25 m LAT3F-50 Stroke 50 mm, Resolution
12 V Lead wire length symbols: 0.5 m Nil (Example) R73C 3 m L (Example) R73CL 5 m Z (Example) R73CZ None N (Example) R73CN 11-2-20 20 Series CRB2BWU Rotary Actuator with Angle Adjuster Vane Style Construction (Same switch units are used for both single and double vane type.)
) TL JJ US TA TD G L UW TB TC M N b l 90 180 90 180 90 180 3 29 104 130 122 153 20 0 0.03 1 15 59 24.5 8 11 9.6 11.5 4 13.5 27 4 4 2.5 74 20 M5 x 0.8 depth 6 0 0.03 30 2 18 65 27 10 13 11.4 13.5 19 36 4 4 2.5 83 4 33 4 20 40 139 177 5 37 5 M6 x 1 depth 7 0 0.03 93 11 20 15 14 17 25 73 32.5 2 20 5 3.5 39.5 5 Dimension AU does not indicate the dimension when shipped because of the adjustment
12 V Lead wire length symbols: 0.5 m Nil (Example) R73C 3 m L (Example) R73CL 5 m Z (Example) R73CZ None N (Example) R73CN 11-2-20 20 Series CRB2BWU Rotary Actuator with Angle Adjuster Vane Style Construction (Same switch units are used for both single and double vane type.)
12 V Lead wire length symbols: 0.5 m Nil (Example) R73C 3 m L (Example) R73CL 5 m Z (Example) R73CZ None N (Example) R73CN 11-2-20 20 Series CRB2BWU Rotary Actuator with Angle Adjuster Vane Style Construction (Same switch units are used for both single and double vane type.)
Applicable Cylinders Weight (g) Cylinder series Bore size (mm) D-G5NB Auto switch model CDM2-Z, CDM2, CDBM2, CDVM3, CDVM5, CDLM2, CDLG1, MLGC CDG1-Z, CDG1 CDA2-Z, CDA2, CDBA2, CDV3, CDVS1, CDL1 MGC, MGG 20, 25, 32, 40 3 m (L) 79 Lead wire length 20, 25, 32, 40, 50, 63, 80, 100 5 m (Z) 125 40, 50, 63, 80, 100 20, 25, 32, 40, 50 Operating Range Bore size (mm) 20 Cylinder series 35 25 40 32
Furthermore, if the cable length exceeds 5 m, then it will decrease by up to 10% for each 5 m. (At 15 m: Reduced by up to 20%) Note 6) The allowable speed for pushing operation. When push conveying a workpiece, operate at the vertical work load or less. Note 7) A reference value for correcting an error in reciprocal operation.
Symbol Stations Note 02 2 stations Double wiring Note 1) 16 02 16 stations 2 stations Specified layout Note 2) (Available up to 32 solenoids) 20 20 stations Symbol A, B port P, E port A, B port size (Metric) Symbol A, B port P, E port A, B port size (Inch) Applicable series Applicable series C3 C4 C6 C4 C6 C8 C6 C8 C10 M N1 N3 N7 N3 N7 N9 N7 N9 N11 M 3.2 One-touch fitting 4 One-touch fitting
(The switch will stay ON all the time.) 1) For an auto switch without a connect protection circuit, use a contact protection box when the wire length is 5 m or longer. 2) Even if an auto switch has a built-in contact protection circuit, when the wiring is more than 30 m long, it is not able to adequately absorb the rush current and its life may be reduced.
With cable (1.5 m) 2 to 24 2 to 24 P. 398 With cable (3 m) With cable (3 m) stations stations With cable (5 m) With cable (5 m) Terminal block box 2 to 20 stations Note 2) L kit (Serial transmission) kit (Circularconnector) S M kit (Lead wire) The valve is equipped with an indicator light and surge voltage suppressor, and the voltage is 24 VDC.
Nil (Example) A73C 3 m L A73CL 5 m Z A73CZ None.
L M L M L M N N Grommet Conduit DIN connector Conduit terminal Electrical entry Port size P Rc(PT) A C D E F Model 22.5 B1 B2 18 21 21 20 20 20 74.5 90 98 30 35 40 19 25 25 20 23 25.5 29 32 32 14.5 17 17 6 7.5 7.5 23 25.5 28 46.5 55 62 39 41.5 44.2 38.5 47 55 59 60 62 38.5 47 54 47 48 50 92 95 97 38.5 47 55 59 62 64 , , , VX31 VX32 VX33 1 4 1 8 27.5 27.5 3 8 1 4 3 8 1 4 4.1-51 VXV31/32/33
Minimum operating pressure differential 2) Install an air filter. Install an air filter close to the valve on the upstream side. A filtration degree of 5 m or less should be selected.
Under certain circumstances, the use of an electronic style pressure gauge is recommended. 1.5-22 ARM1000/2000 Dimensions Dimensions A 4.5 4.5 B 25 34.5 C 34 43 D 21 28 E 18 27 F 56 70 G 16 20 H 9 11.5 J 18 24 K 19 28 M 52 66 P 9 11.5 Q 11.5 16.5 R 4.8 4.8 Symbol Model ARM1000 ARM2000 Dimensions by Number of Stations Manifold stations (n) Symbol Model 1 36 27 48 39 2 55 46 76 67 5 112 103
, 32 (mm) CS1 Model F L K P Q S SS Z ZZ C76 CXWM20-225 94.5 239 20 90 520 227 279 506 534 CXWM20-250 107 264 20 90 570 252 304 556 584 C85 CXWM20-275 119.5 289 20 90 620 277 329 606 634 CXWM20-300 132 314 20 90 670 302 354 656 684 C95 CXS 10 M L CXS 15 M L CXS 20 M L CXS 25 M L CXS 32 M L Model Stroke SS ZZ Z Model F L K P Q S SS Z ZZ CP95 175 257 287 200 282 312 125 207 237 150 232 262 110
3 3 m B 15 m* LER 5 5 m C 20 m* 2N LECP2* Programless type (With stroke study) *1 The standard cable should be used on fixed parts.
B + Stroke L K 2 x 4-M6 x 1.0 effective depth 10 A + Stroke M W Rod end male threads H1 Rod end nut C1 X L1 Rod end male threads mm Bore size (mm) C1 X H1 L1 20 25 18.5 12 14 M8 x 1.25 22.5 15 17.5 M10 x 1.25 Standard type mm A B C D E E1 E2 F H K L M Q W Bore size (mm) 20 25 Stroke range (mm) 15 to 50 36.5 32 7 10 36 18 21 15.5 M5 x 0.8 8 4.5 25.5 21 39 15 to 50 41.5 36.5 12 12 40 20 23.5