Never use in an atmosphere of explosive gases. 1. Perform the following maintenance periodically in order to prevent possible danger due to unexpected auto switch malfunction. The construction of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 1) Securely tighten switch mounting screws.
Calculating Acceleration/deceleration conversion example using an actuator with a 8 [mm] lead with an acceleration of 3000[mm/sec2].
Never use in an atmosphere of explosive gases. 1. Perform the following maintenance periodically in order to prevent possible danger due to unexpected auto switch malfunction. The structure of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2.
It is deduced from the calculation of the pressure changes inside an air tank when discharging the compressed air in a choked flow, from an equipment attached to the air tank.
Calculating Acceleration/deceleration conversion example using an actuator with a 8 [mm] lead with an acceleration of 3000[mm/sec2].
Do not use in an atmosphere containing an inflammable gas or explosive gas. Use in such an atmosphere is likely to cause a fire or explosion. This system is not explosion-proof. Caution 1. Select the proper type of enclosure according to the environment of operation.
However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
The switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 2. Mount the switch in a locations where there is no vibration greater than 98 m/s2 or impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.
IDF-S1966 115 VAC Option symbol R With an earth leakage breaker The air dryer is equipped with an earth leakage breaker, reducing the electrical wiring required during installation.
, making it possible to hold a cylinder intermediate stopping position for an extended time.
Note 2) On the AMC220, an R 1/4 fittinng can be attached by removing the drain cock. (It be comes the drain piping type.
Conforming to ISO 16030-2001, the chamfered dimensions shown in the First, tighten it by hand, then give it an additional 1/6 turn to 1/4 turn with a wrench. A reference value for the tightening torque is 1 to 1.5 Nm. Note) Excessive tightening may damage the thread portion or deform the gasket and cause air leakage. table below are recommended.
Use these holes during reinstallation after the table has been removed for the maintenance of an identical product.
An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. 8 Direct Operated 2 Port for Oil Series VCL 2 Port Solenoid Valve for Fluid Control/Precautions 1 Be sure to read before handling Precautions on Design Selection Warning Warning 1. Cannot be used as an emergency shutoff valve, etc.
Provided with an end lock mechanism An end lock is also available, which maintains the cylinders original position even if the air supply is interrupted.
Thread size M4 x 0.7 8 2 46 Effective thread length (mm) Quantity P.C.D.
Note 1) The industrial filter/vessel series described in this catalog are products in which an element is incorporated into a vessel. To order only an element (replacement part), refer to How to Order on pages 41 and 42.
Avoid the use in an environment where the cylinder is exposed to coolant, cutting oil, water droplets, adhesive materials and dust, or an operation with compressed air that contains drainage or other extraneous materials.
Using an electronic style pressure gauge is recommended, depending on the situation.
Using an electronic style pressure gauge is recommended, depending on the situation.