An amplifying circuit and a dividing circuit are required to produce output which can be read by the counter, and these are attached to the cylinder case. The sensor head and amplifier section together are referred to as the sensor unit.
For applications that do not require speed control, as long as objects are moved smoothly. Or for applications in which a pneumatic speed controller suffices (3l/min).
It can be used alone as a tank. The pressure vessel law is different from country to country, so as an air tank suitable to a country needs to be confirmed.
To operate a relay as a load, use the relay shown in the table below or the equivalent, in order to extend the life of the switch. qWhen handling the product, do not drop an object on it, gouge it, or apply an excessive impact on it. wDo not operate it in an area in which a large amount of magnetism is present.
Install an air filter. Install an air filter upstream near the valve. Select an air filter with a filtration size of 5 m or smaller. 2. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause a malfunction of pneumatic equipment such as valves.
Use a contact protection box in cases such as with an induction load, when the lead wire is longer than 5m or with 100VAC. 1 Operating load is an induction load. 2 Wiring to the load is 5m or longer. Contact protection box internal circuits 3 Load voltage is 100VAC. CD-P11 Use a contact protection box in any of the above listed situations.
Origin Home Switch Infotmation LX series actuators are available with an optional photo micro sensor as an origin home switch to detect when the actuator is fully retracted. The LCOC seies positioning drjver requires an input from the origin home switch or some other sensor when homing the actuator.
Necessary counter-measures for possible lightning surge should be fitted to system components as required. 5. Do not operate in locations having an atmosphere of flammable, explosive or corrosive gases, which can result in fire, explosion or corrosion. The air catch sensor does not have an explosion proof rating.
As a result, it is necessary for the customer to verify compliance with the EMC directive for the machinery and equipment as a whole. The actuator and controller are sold as a package. Confirm that the combination of the controller and actuator is correct.
Applicable Model D L A Fitting Size d Inch 3.2(1/8) KQP-01 5 31.5 16 Applicable Model D L A Fitting Size d mm 3.2 KQP-23 3.2 31.5 16 4(5/32) KQP-03 6 32 16 4 KQP-04 6 32 16 4.8(3/16) KQP-05 6.8 34 17.5 6 KQP-06 8 35 18 6.3(1/4) KQP-07 8.5 35 18 8 KQP-08 10 39 20.5 8(5/16) KQP-09 10 39 20.5 10 KQP-10 12 43 22 9.5(3/8) KQP-11 11.5 43 22 12 KQP-12 14 46 24 12.7(1/2) KQP-13 15 46 24 16 KQP-14
Low & uniform speed actuation Smooth, uniform speed actuation ranges as low as 0.3mm/s. Long life Long life of 10,000km or 100 million full cycles. Low friction Low operating resistance and high stability allow force control as low as 0.05N. (Based on cylinder Piston area x Pressure accuracy) No increased operating resistance after periods of non-operation.
Right LB Rod end thread type Nil M Female thread Male thread Left LD Rod end thread type is an optional product. (Refer to page 266). Note) Indicates the relative position of the foot bracket and port, as seen from the rod side.
Cannot be used as an emergency shutoff valve, etc. The valves presented in this catalog are not designed for safety applications such as an emergency shutoff valve. If the valves are used in this type of system, other reliable safety assurance measures should also be adopted. 2. Maintenance space The installation should allow sufficient space for maintenance activities. 3.
As a guide, it can be tightened about 90 past the position at which tightening can be felt.
Output Black lead wire 50 MSM5AZP1A Mitsubishi Electric Corporation HC-PQ053 50 SGME-A5BF12 Yaskawa Electric Corporation Blue lead wire SGME-A5AF12 50 H S For motor mounting dimensions, refer to the dimensions for series LJ1 10 on page 143 as a reference for mounting and design. Refer to pages starting with 205 for driver dimensions, etc.
How to manually change from an unlocked state to a locked state To change from an unlocked state to a locked state: Unlike the procedure for manually disengaging the lock, never rotate the pin by striking it, as it could bend or damage the pin. The lock is disengaged at the time of shipment.
Using flexible cable as standard spec.
Note 4) When n is an odd number, an even number that is one larger than this odd number is used for the calculation. However, the minimum even number is 4. So, 4 is used for the calculation when n is 1 to 3.