Size: 32, Motor Mounting: Top Mounting Type, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: A [LEY25, 12mm; LEY32, 16(20)mm], Stroke: 450mm, Motor Option: w/o Option, Rod End: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Ends Tapped (Standard), Actuator Cable Type: Standard Cable, Cable Length: 2m, Controller Type: LECSA2, 200V to 230V, I/O Connector:
Size: 25, Motor Mounting: Right Side Parallel Type, Motor Type: S2 [AC Servo Motor, (Incremental Encoder), Output 100W], Lead: A [LEY25, 12mm; LEY32, 16(20)mm], Stroke: 300mm, Motor Option: w/o Option, Rod End: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Type: Standard Cable, Cable Length: 2m, Controller Type: LECSA2, 200V to 230V, I/O Connector: w/Connector
Size: 32, Motor Mounting: Top Mounting Type, Motor Type: S3 [AC Servo Motor, (Incremental Encoder), Output 200W], Lead: B [LEY25, 6mm; LEY32, 8(10)mm], Stroke: 150mm, Motor Option: w/o Option, Rod End: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Ends Tapped (Standard), Actuator Cable Type: Standard Cable, Cable Length: 2m, Controller Type: LECSA2, 200V to 230V, I/O Connector: w
Size: 32, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: Top Mounting, Motor Type: S3 (AC Servo Motor, Incremental Encoder, Output 200W), Lead: B (LEY25 6mm; LEY32 8mm; LEY32 Top Mount 10mm), Stroke: 200mm, Motor Option: w/o Option, Guide Option: w/o Guide, Cable Type: S (Standard Cable), Cable Length: 2 (2m), Driver Type: A2 (LECSA2-S, 200~230V Incremental, Pulse Input)
Size: 32, Bearing Type: M (Sliding Bearing), Motor Mounting Position: Top Mounting, Motor Type: S3 (AC Servo Motor, Incremental Encoder, Output 200W), Lead: B (LEY25 6mm; LEY32 8mm; LEY32 Top Mount 10mm), Stroke: 200mm, Motor Option: w/o Option, Guide Option: w/o Guide, Cable Type: S (Standard Cable), Cable Length: 2 (2m), Driver Type: A2 (LECSA2-S, 200~230V Incremental, Pulse Input), I/O
Size: 32, Bearing Type: M (Sliding Bearing), Motor Mounting Position: Top Mounting, Motor Type: S3 (AC Servo Motor, Incremental Encoder, Output 200W), Lead: A (LEY25 12mm; LEY32 16mm; LEY32 Top Mount 20mm), Stroke: 150mm, Motor Option: w/o Option, Guide Option: w/o Guide, Cable Type: S (Standard Cable), Cable Length: 2 (2m), Driver Type: A2 (LECSA2-S, 200~230V Incremental, Pulse Input), I
Size: 32, Bearing Type: M (Sliding Bearing), Motor Mounting Position: Top Mounting, Motor Type: S3 (AC Servo Motor, Incremental Encoder, Output 200W), Lead: B (LEY25 6mm; LEY32 8mm; LEY32 Top Mount 10mm), Stroke: 150mm, Motor Option: w/o Option, Guide Option: w/o Guide, Cable Type: S (Standard Cable), Cable Length: 2 (2m), Driver Type: A2 (LECSA2-S, 200~230V Incremental, Pulse Input), I/O
Accuracy: H (High Precision), Motor Mounting Position: Top Mounting, Motor Type: S4 [AC Servo Motor, (Incremental Encoder), 400W], Lead: A (20mm), Stroke: 400mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped (Standard), Cable Type: S (Standard Cable), Cable Length: 2m, Driver Type:
A high rigidity, slider type electric actuator, series LEJ is available in both ball screw, LEJS, and belt drive, LEJB models. The LEJ offers 2 types of motor cables, standard and robotic (flexible). Seal bands, equipped as standard, cover the guide preventing grease from splashing, and external foreign matter from entering. LEJS (ball screw drive) can be used for both horizontal and
Accuracy: Basic Type, Size: 63, Motor Type: S3 (200W Output, Incremental Encoder), Lead Screw: B (LEJS40: 8mm; LEJS63: 10mm), Stroke: 1200mm, Motor Option: B (w/Lock), Actuator Cable Type: S (Standard Cable), Cable Length: 2 (2m), Driver: A1 (LECSA1-S, 100~120V, Incremental, Pulse Input)
A high rigidity, slider type electric actuator, series LEJ is available in both ball screw, LEJS, and belt drive, LEJB models. The LEJ offers 2 types of motor cables, standard and robotic (flexible). Seal bands, equipped as standard, cover the guide preventing grease from splashing, and external foreign matter from entering. LEJS (ball screw drive) can be used for both horizontal and
A high rigidity, slider type electric actuator, series LEJ is available in both ball screw, LEJS, and belt drive, LEJB models. The LEJ offers 2 types of motor cables, standard and robotic (flexible). Seal bands, equipped as standard, cover the guide preventing grease from splashing, and external foreign matter from entering. LEJS (ball screw drive) can be used for both horizontal and
A high rigidity, slider type electric actuator, series LEJ is available in both ball screw, LEJS, and belt drive, LEJB models. The LEJ offers 2 types of motor cables, standard and robotic (flexible). Seal bands, equipped as standard, cover the guide preventing grease from splashing, and external foreign matter from entering. LEJS (ball screw drive) can be used for both horizontal and
460 600 450 Dimensions inside ( ) are for a 100 mm stroke.
460 600 450 Dimensions inside ( ) are for a 100 mm stroke.
mm] 600 600 600 600 Me X 400 400 400 400 m 200 200 200 200 0 0 0 0 0 10 20 30 50 40 0 20 40 60 80 0 10 5 15 20 0 10 5 15 20 30 25 Work load [kg] Work load [kg] Work load [kg] Work load [kg] 1000 1000 1000 1000 800 800 800 800 Me L5 [mm] L5 [mm] L5 [mm] L5 [mm] m 600 600 600 600 L5 Wall Y 400 400 400 400 200 200 200 200 0 0 0 0 0 10 20 30 50 40 0 20 40 60 80 0 10 5 15 20 0 10 5 15 20 30 25
A B C D Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) 15 20 25 30 1000 1000 930 740 600 500 Note Model LJ1H202PC-500LJ1H202PC-600LJ1H202PC-700LJ1H202PC-800LJ1H202PC-900LJ1H202PC-1000700 700 600 600 500 500 500 500 500 500 500 500 500 500 500 500 500 500 Power supply: 100/110(V)AC 10% Compatible controller: LC1-1B2H1Power supply: 200/220(V)AC 10% Compatible controller
, 700, 800 900, 1000, 1200 300, 400, 500, 600, 700, 800, 900 1000, 1200, 1500 LEF Work load [kg] Note 2) Horizontal 15 30 55 30 45 85 Vertical 3 5 10 6 10 20 LEJ Up to 500 1800 1200 600 1800 1200 600 501 to 600 1580 1050 520 1800 1200 600 601 to 700 1170 780 390 1800 1200 600 701 to 800 910 600 300 1390 930 460 801 to 900 720 480 240 1110 740 370 901 to 1000 580 390 190 900 600 300 1001 to
Specifications Model LEJS40 LEJS63 Stroke [mm] Note 1) 200, 300, 400, 500, 600, 700, 800 900, 1000, 1200 300, 400, 500, 600, 700, 800, 900 1000, 1200, 1500 Work load [kg] Note 2) Horizontal 15 30 55 30 45 85 LEF Vertical 3 5 10 6 10 20 Up to 500 1800 1200 600 LEJ 1800 1200 600 501 to 600 1580 1050 520 601 to 700 1170 780 390 LEL 701 to 800 910 600 300 1390 930 460 801 to 900 720 480 240 1110
Wall Note) For air-cooled type, leave a space of at least 600 mm between the heat exhausting surface and the wall. For water-cooled type, leave a space at least 600 mm between the facility water piping side and the wall. Leave at least 600 mm on the sides indicated with .