Clean Series: 10 (Relief Type), Magnet: D (Built-in), Mounting: B (Basic Style), Bore Size: 32mm, Port Thread: Rc, Stroke: 75mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Magnet: D (Built-in Magnet), Mounting: B (Basic, Double-side Bossed), Bore: 25mm, Port Thread: Rc, Stroke: 75mm, Cushion: None, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: D (Built-in), Type: Pneumatic, Mounting: E (Integral Clevis), Bore: 40mm, Port Thread: Rc, Stroke: 75mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: N (Pivot Bracket not assembled), Rod End Bracket: V (Single Knuckle Joint), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Magnet: D (Built-in), Type: Pneumatic, Mounting: C (Single Clevis), Bore: 32mm, Port Thread: Rc, Stroke: 75mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: N (Pivot Bracket not assembled), Rod End Bracket: V (Single Knuckle Joint), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Magnet: Built-in Magnet, Mounting: Basic, Double-side Bossed, Bore: 25mm, Port Thread: Rc, Stroke: 75mm, Cushion: None, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: Built-in, Type: Pneumatic, Mounting: Single Clevis, Bore: 32mm, Port Thread: Rc, Stroke: 75mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: Pivot Bracket not assembled, Rod End Bracket: Single Knuckle Joint, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Leadwire or Prewired Connector: -, Number: -
Clean Series: Relief Type, Magnet: Built-in, Mounting: Basic Style, Bore Size: 32mm, Port Thread: Rc, Stroke: 75mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Clean Series: Vacuum Suction Type, Magnet: Built-in, Mounting: Bottom Mounting Style, Bore Size: 20mm, Port Thread: Rc, Stroke: 75mm, Rod End Thread: Male Rod Thread, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Bearing Type: L (Ball Bushing), Bore Size: 40mm, Thread Type: Rc; Bore Size 12, 16: M5 x 0.8, Stroke: 75mm, Stroke Adjustment: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XB13 (Low Speed Cylinder, 5 to 50mm/s)
(M)(L)(Z) D-A93(M)(L)(Z) M9// Without auto switch (with magnet) * Standard lead wire length is 0.5 m.
Note 4) Figures in ( ) in the table W are D-A93.
-X168 (Example) MY2H40G-599L-A93-XB10 Symbol Symbol 2 Long Stroke -XB11 4 Copper-free 20Available with long strokes exceeding the standard strokes.
Please contact SMC regarding water resistant types with the above model numbers. 2 1 m lead wire is only applicable to the D-A93. None N (Example) H7CN Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed above, refer to page 111 for details.
Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.
44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.
A water-resistant type cylinder is recommended for use in an environment which requires water resistance. *2 1 m type lead wire is only applicable to D-A93. * Solid state auto switches marked with v are produced upon receipt of order. * Do not indicate suffix N for no lead wire on the D-A3A/A44A/G39A/K39A models. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM
D-A90(V)/D-A93(V)/D-A96(V) Direct Mounting Style .
The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap
Please consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked with p are produced upon receipt of order.
D-M9/M/9W/M9A Less than 20 stroke Note 2) Less than 55 stroke Note 2) D-A90/A93 Less than 50 stroke Note 2) Note 2) Minimum stroke for auto switch mounting in types other than those mentioned in Note 1. 152 Auto Switch Mounting CJ2Y Series Operating Range Auto Switch Mounting Brackets/Part No.