S Mounting bracket n pcs. n B Basic type Type of auto switch L Axial foot type F Front flange type Nil Without auto switch G Rear flange type Select the applicable auto switch type from the table below.
ISO Class N: Occupancy state: Considered particle size The number of particles diameter larger than 0.5 m in an air volume of 1m3 is expressed in 10M or coefficient Nc.
Piping thread type : When N is selected, NPT thread adapter set will be added.
25-MLA [ISE35-N-25-M (Switch body only)] Digital pressure switch Note 5) NPN output: Wiring top entry ISE35-R-25-MLA [ISE35-R-25-M (Switch body only)] PNP output: Wiring bottom entry ISE35-N-65-MLA [ISE35-N-65-M (Switch body only)] PNP output: Wiring top entry ISE35-R-65-MLA [ISE35-R-65-M (Switch body only)] Note 1) Assembly of a bracket and set nuts.
25-MLA [ISE35-N-25-M (Switch body only)] NPN output / Wiring bottom entry ISE35-R-25-MLA [ISE35-R-25-M (Switch body only)] NPN output / Wiring top entry Note 4) Digital type ISE35-N-65-MLA [ISE35-N-65-M (Switch body only)] PNP output / Wiring bottom entry ISE35-R-65-MLA [ISE35-R-65-M (Switch body only)] PNP output / Wiring top entry Note 1) Assembly includes a bracket and set nuts.
25-MLA [ISE35-N-25-M (Switch body only)] NPN output / Wiring bottom entry ISE35-R-25-MLA [ISE35-R-25-M (Switch body only)] NPN output / Wiring top entry Note 4) Digital type ISE35-N-65-MLA [ISE35-N-65-M (Switch body only)] PNP output / Wiring bottom entry ISE35-R-65-MLA [ISE35-R-65-M (Switch body only)] PNP output / Wiring top entry Note 1) Assembly includes a bracket and set nuts.
Calculation of applied lateral load F F = N m g (N) = 0.2 x 10 x 0.1 x 9.8 = 2.1 (N) 1. Calculation of applied lateral load The lateral load F equals the total load of the work piece. Thus, F= 5 x 0.05 x 9.8 = 2.5 (N) 70 Lateral load F (N) 60 0.4MPa 50 40 2. Confirmation of allowable lateral load From the graph, the allowable lateral load at L=50mm and P=0.4MPa is 18N. 2.
Thread type Body option N n pcs.
Moreover, leakage current flow to the load will be n times larger when n auto switches are connected in parallel. 7. Do not use a load that generates surge voltage.
Mount of single unit 24 or more 0 -0.4 31 31 x n pcs. + 3.5 x (n pcs. 1) 31 0 -0.4 0 -0.4 31 Vertical stacking mount of multiple units (n pcs.) 0 -0.4 31 24 or more 31 x n pcs. + 3.5 x (n pcs. 1) 7 Pressure Sensor Controller Series PSE300 Functions A Auto shift function D Peak and bottom display function When there are large fluctuations in the supply pressure, the switch may fail to operate
(PT) 1/8, M5 x 0.8 (port A) 19 35 n-Rc(PT) 1/8 (port R) 47.5 11 R R P = 19 19 L: Dimension table n: Stations n L 1 38 27 2 57 46 3 76 65 4 95 84 5 114 103 6 133 122 7 152 141 8 171 160 9 190 179 10 209 198 11 228 217 12 247 236 13 266 255 14 285 274 15 304 293 16 323 312 17 342 331 18 361 350 19 380 369 20 399 388 L1 L2 5 Series VKF300 Dimensions/Manifolds Base Mounted Type Common SUP, Common
Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For
(Thread symbol N: 3/8 inch) (820) [200 VAC specification] Terminal block K L H M N J 4-13 P [200 VAC specification] Power cord outlet (17) [100 VAC specification] Power cord (mm) A B C D E F G H J K L M N P Q Port size Model IDF1E IDF2E IDF3E IDF4E IDF6E IDF8E IDF11E 69 101 270 32 21 330 413 38 150 3/8 226 410 240 15 51 232 138 24 327 125 67 304 33 73 31 36 154 21 330 473 1/2 13 453 283
Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For
These are listed in terms of kilohertz, meaning thousand rydes.' tq,,*"n*"r JIILL Linear Guide applications needing high preosion, high rigility, high repeatahtity, and tow lriction. Lineadty overa range of input values.
VC Model VDW VQ Thread type Nil T F N Orifice size Rc NPTF G NPT 1 2 3 4 1.5 mm 2.2 mm 3 mm 4 mm VX2 VX Refer to the table (1) given below for availability. VX3 Port size 01 02 03 1 8 1 4 3 8 VXA Valve/Body 4 Common/Single unit Refer to the table (1) given below for availability.
Connect the stripped cable to the L, N, PE terminals(For 400V, L1, L2, L3, PE) of the female connector. (Recommended tightening torque: 0.7 Nm) Female connector Screw (Recommended thightening torque : 0.7Nm) PE 2(N) 1(L1) 1(L) 2(L2) PE 3(L3) 200V type 400V type Fig 3-5 Cable connection HRR Series 3.3 Installation 3-11 HRX-OM-X071 Chapter 3 Transport and Setting Up 5.
Without auto switch With auto switch Proper tightening torque N m 0.54 Bolt M2.5 x 0.45 10 CUJB4 C(D)UJB6 C(D)UJB8 C(D)UJB10 0.5 1.06 M3 x 0.5 10 0.4 0.4 Allowable lateral load W (N) Allowable lateral load W (N) 8 0.3 0.3 8 0.2 0.2 Tightening torque Tightening torque 6 6 0.1 0.1 4 Allowable Kinetic Energy 0 4 6 8 10 15 20 Stroke ST (mm) 0 4 6 8 10 15 20 Caution Stroke ST (mm) When driving