SMC Corporation of America
Elite Part Number Search
Search Results "PF3W704S-03-DT-MR-X365"

Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: Flow Adjustment Valve, Thread: Rc, Port Size: 3/8, Output Specification: OUT1: NPN; OUT2: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: Flow Adjustment Valve, Thread: Rc, Port Size: 3/8, Output Specification: OUT1: NPN; OUT2: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 0.5 to 4 L/min, Flow Adjustment Valve: w/Flow Adjustment Valve, Thread: Rc, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes, Lead Wire: w/o Lead Wire and M8 Connector, Unit Specification: Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C, Bracket: w/Bracket, Calibration Certificate

Rated Flow Range: 0.5 to 4 L/min, Flow Adjustment Valve: w/Flow Adjustment Valve, Thread: Rc, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None, Lead Wire: w/o Lead Wire and M8 Connector, Unit Specification: Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C, Bracket: w/Bracket, Calibration

Rated Flow Range: 0.5 to 4 L/min, Flow Adjustment Valve: w/Flow Adjustment Valve, Thread: Rc, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C, Bracket: w/Bracket, Calibration

Rated Flow Range: 0.5 to 4 L/min, Flow Adjustment Valve: w/Flow Adjustment Valve, Thread: Rc, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None, Lead Wire: w/o Lead Wire and M8 Connector, Unit Specification: Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C, Bracket: None, Calibration

Rated Flow Range: 0.5 to 4 L/min, Flow Adjustment Valve: w/Flow Adjustment Valve, Thread: Rc, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration

Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: JT (OUT1: Analogue 1 to 5 V - OUT2: Analogue 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket:

Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C)

The amount of rod movement in the stroke reading cylinder is detected using an MR element (magnetic resistance element) whose resistance value changes due to magnetic force. The detection unit containing this MR element is called the sensor head.

The detection unit containing this MR element is called the sensor head. An amplifying circuit and a dividing circuit are required to produce output which can be read by the counter, and these are attached to the cylinder case. The sensor head and amplifier section together are referred to as the sensor unit.

The amount of rod movement in the stroke reading cylinder is detected using an MR element (magnetic resistance element) whose resistance value changes due to magnetic force. The detection unit containing this MR element is called the sensor head.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CBA2 Applicable to 40 to 63 CV Valve mounted cylinder Applicable to 40 to 63 Series CA2 (CVS, CV3, CBA) Series CS1 MR= MH= MR= MH= Precautions 1. To order, specify the M dimension as well as the part number. 2.

CB CD DD E F FL LR M MR R NCA1-P150 3/4 1/2 13/32 2 1/2 3/8 1 1/8 3/4 1/2 9/16 1.63 NCA1-P325 1 1/4 3/4 17/32 3 1/2 5/8 1 7/8 1 1/4 3/4 7/8 2.56 CD dia. DD dia. Clevis Bracket AA 2.3 3.6 1 5/8 2 9/16 0.785 1.265 1/2 3/4 1/2 5/8 3/8 -24 1/2 -20 2 1/2 3 1/2 3/8 5/8 1 1/8 1 7/8 1/2 1 1/16 1/2 3/4 9/16 1 1/16 Part no. BA CB CD CW DD E F FL LR M MR NCA1-CB150 NCA1-CB325 DD dia.

Operating condition Model LC3F2 A LEC-MR-RB-032 B LEC-MR-RB-12 Allowable Stroke Speed [mm/s] Model AC servo motor Lead Stroke [mm] Symbol [mm] Up to 100 Up to 200 Up to 300 Up to 400 Up to 500 Up to 600 Up to 700 Up to 800 Up to 900 Up to 1000 Up to 1100 Up to 1200 H 20 1500 1200 900 700 550 A 12 900 720 540 420 330 B 6 450 360 270 210 160 LEFS25 100 W /l40 (Motor rotation speed) (4500 rpm

LZ Required conditions for Regeneration option Regeneration Option Models LC3F2 Operating condition Regenerative condition Regeneration option A Duty ratio 100% LEC-MR-RB-032 B LEC-MR-RB-12 Regeneration option is required when using product above regeneration line in graph. (Order separately.)

Mp Fv My MHR MHK MHS L MHC MHT MHY L: Distance to the point at which the load is applied (mm) MHW Maximum allowable moment Allowable vertical load Fv (N) Model Pitch moment Mp (Nm) Yaw moment My (Nm) Roll moment Mr (Nm) MRHQ MHF2-8D 0.53 0.26 0.26 58 Misc.

Mp MHS Fv L MHC MHT MHY L: Distance to the point at which the load is applied (mm) Maximum allowable moment MHW Allowable vertical load Fv (N) Model Pitch moment: Mp (Nm) Yaw moment: My (Nm) Roll moment: Mr (Nm) MRHQ MHZ2-6 0.08 0.04 0.04 10 Misc.

The detection unit containing this MR element is called the sensor head. An amplifying circuit and a dividing circuit are required to produce output which can be read by the counter, and these are accommodated in the case on the cylinder. The sensor head and amplifier section together are referred to as the sensor unit.

Mp Fv My MHR MHK Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MHS L MHC MHT MHY L: Distance to the point at which the load is applied (mm) MHW Maximum allowable moment Allowable vertical load Fv (N) Model Pitch moment Mp (Nm) Yaw moment My (Nm) Roll moment Mr