() () () () () () () Q1 N.C. () () () () () () 5 DC24V Q2 () () 6 DC12V Assy 1) Ass'y 2 L L AXT661 LO L M L2) (mm) 300 MO L2) 14A ()()() 6 600 (NC) 1) 10 1000 13A () () 20 2000 300mm 30 3000 3 Ass'y ZB1-VQ110U(M1.7X15)2 2)M ZB1-VQ110U-B (M1.7X22)2 3) ZB1-VQ110L(M1.7X22)2 ZB1-VQ120U(M1.7X15)2 B () ZB1-VQ120U-B (M1.7X22)2 3) ZB1-VQ110(M1.7X15)2 4) 3 ZB1-VQ110-B (M1.7X22)2 V Assy
CUJ (As compared with SMC Series CU cylinders without magnet) Dimensions (without magnet) (mm) b Bore Size A (a) B (b) C (c) B 4 6 8 10 10 () 15 () 13 () 13 (13) 19 (22) 13 (33) c + Stroke C + Stroke 13 () 21 () 13 () A 13.5 (15) 22 (24) 13 (36) a Numbers in parentheses are the dimensions of SMC Series CU cylinders.
A B 1 Actuator section PPS 2 Body PFA A B 3 Diaphragm PTFE 4 End plate PPS 5 Flow rate adjuster section PPS 503 Series LVD Dimensions Basic type A D L K 4 x M (Q) 2 x P One-touch fitting Breathing port PB H C PA G A B N E J B (F) T 2 x U PB PA A B Pilot port threaded type With flow rate adjustment (Max.
VFRA4211-03 2 position double 1.2 1 8 65 (3.6) 67 (3.7) VFRA4211-04 VFRA4311-03 3 position closed center 1.2 1 8 57.6 (3.2) 1.1 1 8 57.6 (3.2) PA, B: 51 (2.8) A, BEA, EB: 57.6 (3.2) [A, BEA, EB: 45 (2.5)] VFRA4311-04 3 8 VFRA4411-03 3 position exhaust center 1.2 1 8 PA, B: 51 (2.8) A, BEA, EB: 57.6 (3.2) [A, BEA, EB: 45 (2.5)] 1 2 VFRA4411-04 3 8 65 (3.6) [PA, B: 30.6 (1.7)] VFRA4511-03
A 4 B 2 Indicator light 6 A 4 B 2 A B 5 SMC SMC SMC SMC SMC A A A A A B B B B B Manual override A 4 B 2 A B A B A A B 4 L2 L1 B 2 A 4 3 B 2 A 4 2 34.5 48 68.5 P=41 58.5 P=41 B 2 A 4 1 X 12 Stations R4.5 D side 107.8 179 (single, double, 3 position, rubber type) 184.5 (3 position, metal type) 15.5 17 22 51 69 117 2-Rc1/8 (external pilot port) With connector on D side (FD) 12 Base Mounted
SUP. 3 1 2 3 1 2 3 1 2 E Padlock mounting position D C SUP J 2 2 x K A T IN OUT AA 3 L 2 x P1 (Port size) B V BB U Built-in silencer (Option) M (Width across flats) 3 N P2 (Port size) Q EXH Y Bracket (Option) R S X W Dimensions (mm) Standard specifications Model P1 P2 A B C D E F G H I J K L M 1/8, 1/4 1/4, 3/8 1/8 1/4 3/8 1/2 1/2 66.4 80.3 104.9 110.4 134.3 22.3 29.4 38.5 42 53 40 53 70
Load proportion is ((load weight x 9.8)/theoretical force) x 100% Conditions of Speed Chart System A B C D E F G Solenoid valve Speed controller AS420-04 AS500-06 AS600-10 AS600-10 AS800-12 AS900-14 AS900-20 Tubing diameter x Length SGP15A x 1 m SGP20A x 1 m SGP25A x 1 m SGP25A x 1 m SGP32A x 1 m SGP40A x 1 m SGP50A x 1 m Silencer AN40-04 AN500-06 AN600-10 AN600-10 AN700-12 AN800-14 AN900
more KJS23-M3 KJS04-M3 KJH23-M3 KJH04-M3 KJL23-M3 KJL04-M3 KJW23-M3 KJW04-M3 M-3AU M-3ALU MU Bore size (mm) 6, 8, 10 Port size M3 x 0.5 DStroke (mm) 4 or more One-touch fitting AS121F-M3-23 -X AS121F-M3-04 AS131F-M3-23 20AS131F-M3-04 Only applicable to the mounting position shown in Fig. (1) below.
Note 4) Combinations of M and H, H and M, R and S, S and T, L and M are not available.
Panel adapter B ZS-22-02 Output specifications 0 1 NPN (2 outputs) PNP (2 outputs) Specifications Model PFW300-m PFW301-m PFW310-m PFW311-m PFW321-m PFW320-m 0.5 to 4l/min (0.02 to 0.14SCFM) [Setting is 0.6 to 4l/min (0.02 to 0.14SCFM)] 0.05l/min (0.002SCFM) 5 to 40l/min (0.18 to 1.41SCFM) 2 to 16l/min (0.07 to 0.56SCFM) Flow rate range measurement and setting Minimum setting unit 0.5l/min
300mm (lead wire length) I With indicator light/ surge voltage suppressor G G Manual override (locking lever type) Pressure gauge mounting bore 1/8 Port size Indicator light ON OFF OFF ON B B H H N P A P A 37 37 Q Q C C Pressure gauge mounting bore 1/8 4-R R 4-R 36.8 E 36.8 E R P P D D + + MADE IN JAPAN MADE IN JAPAN SMC SMC Model Port size A B C D E G H I K L M N P Q R AV2000-02-G AV2000
PCA-1558823 Cable with 7/8 inch connector, Socket, Straight 6 m PCA-1558836 Cable with 7/8 inch connector, Socket, Right angle 2 m PCA-1558849 Cable with 7/8 inch connector, Socket, Right angle 6 m PCA-1564927 Cable with M12 connector, B code, Socket, Straight 2 m, SPEEDCON compatible PCA-1564930 Cable with M12 connector, B code, Socket, Straight 6 m, SPEEDCON compatible PCA-1564943 Cable
VBA20A-03 VBA20A-F03 VBA10A-02 VBA10A-F02 VBA11A-02 VBA11A-F02 G27-20-01 AN200-02 ANA1-02 KT-VBA10A-18 VBA40A-04 VBA40A-F04 VBA22A-03 VBA22A-F03 VBA42A-04 VBA42A-F04 VBA43A-04 VBA43A-F04 Model Description Pressure gauge Silencer High-noise reduction silencer Elbow for silencer G27-20-01 AN400-04 ANA1-04 G36-10-01 AN400-04 ANA1-04 KT-VBA22A-7 AN300-03 ANA1-03 G N S L G36-10-01 AN300-03
300mm (lead wire length) I With indicator light/ surge voltage suppressor G G Manual override (locking lever type) Pressure gauge mounting bore 1/8 Port size Indicator light ON OFF OFF ON B B H H N P A P A 37 37 Q Q C C Pressure gauge mounting bore 1/8 4-R R 4-R 36.8 E 36.8 E R P P D D + + MADE IN JAPAN MADE IN JAPAN Model Port size A B C D E G H I K L M N P Q R AV2000-02-G AV2000-02-GS AV2000
.: PNP; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C)
.: PNP; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C)
.: PNP; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C
.: PNP; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C
VVPA4 5 0 04 04 1 Thread type Nil Rc G NPT NPTF VP 5 port Air operated manifold F N T Base size A, B Port size 5 3 4 6 1 Symbol 04 Port size VVPA450 VVPA460 1 2 3 4 Mixed 1 06 10 M (2) Piping Note2) In the case of mixed specifications, indicate M and specify port location sparately on a manifold specification sheet.
2(B) port side: Yellow (DIN rail) (8) 9.5 A A A A B B B B 78.5 66.5 66.2 4 A 4 A 4 A 4 A 47.3 B 2 B 2 B 2 B 2 (5.5) (35) 4.6 (26.1) 5.3 2.2 (12.2) (14.8) 18.6 4 x M4 Mounting hole (Recommended tightening torque: 1.4 N.m) 18 L2 44.8 1.5 18 0.6 m, 1.5 m, 3 m (Lead wire length) (L4) (DIN rail mounting hole pitch: 12.5) (5.3) (Fitting for the type with P/E ports on the U and/or D sides) (L3)