<br>③ If the input signal of the old IT series product was a 2-wire type current type, only 4 to 20 mADC signal wiring was required, with power supply wiring not required.<br>In this case, the ITV series regulator will need to be connected to a power supply.<br><br>The ITV1000/2000/3000 series catalog can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=vacuum-regulators&fa_id=11155
<br>After setting the pressure, be sure to lock the knob. Moving the knob in the downward direction may cause the pressure to drop below the initial setting. <br>The knob rotates clockwise to increase pressure and counterclockwise to decrease pressure. <br>The setting range of the outlet pressure is 85% or less of the inlet pressure.
<br>Replace each product as a whole. <br><br>The production of old AW series (2 digits: AW□□) bowl assemblies has also been terminated, and the supply is limited to whatever is left in stock. <br>Please check the part number of the bowl assembly and confirm whether it can be ordered. <br>If the current stock has run out, replace each product.
<br>The oil drains through the hole (ø6) of the drain cock, but piping cannot be connected to it.<br><br>
<br>It is recommended that the cartridge be replaced if the error occurs again even after cleaning the electrode.<br>Note) Be sure to stop supplying power when cleaning or replacing the emitter.<br><br>
ca_id=161" _blank>catalog<br><br>Note 1) You can change the electrical entry direction in 90° increments by adding XC□ to the end of the part number.<br>Note 2) In the case of a product with bracket, the end of the part number is XB□.<br>(For the applicable models, refer to the catalog.)
<br>Note) For pilot air pressure, refer to the “Specifications” section in the catalog of each series. <br>Reference) SGC and SGH series coolant valve PE ports have a filter mounted as standard.<br><br>
<br><br>Air-operated type:<br>Pilot air from an external 5-port solenoid valve is supplied to drive chambers A and B of the PA main unit via ports P1 and P2.
<br>Follow the procedure below to adjust the flow rate. <br>For the automatically operated type<br>Install a needle valve or other flow adjustment valve on the outlet side of the process pump to adjust the flow rate.
<br>Note) The water-regulating valve of HRS□-W water-cooled thermo-chillers opens and closes depending on the state of the circulating fluid. It opens and closes according to changes in the refrigerant pressure. <br>Facility water will not flow at the start of operation or when the heat load is low.<br><br>
<br>However, if the same alarm or multiple alarms are generated frequently, please contact your local SMC sales office. <br><br>Note 1) These are the default settings of the HRS050. The operating settings can be changed by the user. <br>The default setting for alarm code “AL08” is stop operation for the HRS090 to 200.
<br><br>
<br>(For pilot operated valves, the external pilot type must be selected and additional piping is also required.)<br>The vacuum type models are the VT307V, VT317V, and VT325V, and the operating pressure range is -101.2 kPa to 0.1 MPa.<br>They can also be used to switch between vacuum adsorption and vacuum release. (Vacuum holding is not possible as some air leakage is unavoidable.)
<br><br>
<br>Consider the SY3000/5000/7000 series as a substitute.<br>Some SX series valves may be available for maintenance purposes, so check the part number on the valve and ask your nearest SMC sales office about availability.<br>Note) SX series valves and SY series valves are not interchangeable mounting or connector wise.
<br><br>