Station 2 58 40 Station 20 346 328 Station n L1 L2 3 74 56 4 90 72 5 106 88 6 122 104 7 138 120 8 154 136 9 170 152 10 186 168 11 202 184 12 218 200 13 234 216 14 250 232 15 266 248 16 282 264 17 298 280 18 314 296 19 330 312 39 Series SYJ5000 [ ]: AC Type 40: Bottom Ported/SS5YJ5-40Stations -M5 Grommet (G) Approx. 300 (Lead wire length) 9 L2 L1 4-4.5 (For mounting) 13 36.9 (DIN 38.1) 21.5
Cylinder Speed Chart Bore size Series CS1/CS2 Pressure 0.5 MPa, Load factor 50% Cylinder stroke 300 mm Average velocity (mm/s) System 125 140 160 180 200 250 300 1000 Vertically upward movement Horizontal movement 900 800 700 600 500 400 300 200 100 0 A 800 900 1000 700 600 500 400 300 200 100 0 B 900 1000 800 700 600 500 400 300 200 100 0 C 800 900 1000 700 600 500 400 300 200 100 0 D 800
Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.
Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.
Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) 25 32 40 2000 2000 2000 Stroke adjustment unit symbol Refer to page 1109 for stroke adjustment unit. 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 When stroke is required, which is longer than the standard stroke, refer
, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 25 32 40 2000 2000 2000 *When the required stroke is longer than the standard stroke , refer to the specifications for Made to Order q (p.5.4-79) longer stroke styles.
S070 Nil Standard (Internal pilot) R External pilot Manual override VQ Option Light/Surge voltage suppressor Nil Push type Rated voltage B Locking type (Slotted) Nil None VKF 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz C Locking type (Manual) With light/surge voltage suppressor (Type E, T, D, or Y only) Z Option VQZ 110 to 120 VAC, 50/60 Hz S With surge voltage suppressor (Type G only) 4
250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500 700 900 10 500 700 900 10 700 1,000 Flow rate Q l/min (ANR) How to read the graph The sonic range pressure to generate a flow rate of 500 l/min (ANR) is P1 0.14 MPa for a 6 orifice (VX2 4), and P1 0.3 MPa for a 4.5 orifice (VX23). 3 2 For Saturated Steam [663] (179) Upstream
Internal voltage drop Indicator light (lights when ON) Applications AC DC 24V or less AC DC 48V or less AC DC100V or less 24VDC 100VAC 50mA 40mA 20mA 5 to 40mA 5 to 20mA Relay, PLC, IC circuit D-A90 D-A90V None 0 Relay, PLC D-A93 D-A93V 2.6V or less D-A96 D-A96V 4 to 8VDC 20mA 0.8V or less IC circuit Lead wires D-A90, A93 : Oil resistant heavy duty vinyl cord 2.7 0.18mm x 2 wire (Brown
Station n L1 L2 L3 L4 Station 20 341 328 304 296 3 69 56 32 24 6 117 104 80 72 8 149 136 112 104 10 181 168 144 136 Station 2 53 40 16 8 4 85 72 48 40 5 101 88 64 56 7 133 120 96 88 9 165 152 128 120 11 197 184 160 152 12 213 200 176 168 13 229 216 192 184 14 245 232 208 200 15 261 248 224 216 16 277 264 240 232 17 293 280 256 248 18 309 296 272 264 19 325 312 288 280 24 Series SYJ500 Type
DataA: Inlet Air Temperature F 80 90 100 110 120 130 140 149 C 27 32 37.8 43 49 54 60 65 IDFB60/IDFB70 1.33 1.21 1.00 0.78 0.61 0.48 0.38 0.28 IDFB80/IDFB90 1.38 1.38 1.00 0.83 0.63 0.50 0.45 0.37 DataB: Ambient Temperature F 80 90 100 110 113 C 27 32 37.8 43 45 IDFB60/IDFB70 1.16 1.11 1.00 0.78 0.71 IDFB80/IDFB90 1.40 1.22 1.00 0.88 0.83 DataC: Inlet Air Pressure psi 50 60 70 80 90 100 120
Repetition Pressure characteristics Flow characteristics 0 1 10kPa 20kPa -20 Output deviation factor % F.S. 0.5 40kPa -40 Set pressure kPa Out 60kPa -60 0 Return 80kPa -80 -0.5 100kPa -100 -120 -100 -80 -60 -40 -1 0 1 1.5 0.5 2 2.5 3 3.5 -120 -20 4 Flow rate l/min (ANR) Supply pressure MPa 5 Compact Electro-pneumatic Regulator Series ITV0 Dimensions Single unit 4-6 2-6 PWR L bracket (optional
(mm) 10 9 8 7 6 5 4 3 Manifold stations n L1 L2 2 180 165 150 135 120 105 90 75 60 235.5 223 198 185.5 173 160.5 148 123 110.5 8
VAC. port Silencer dedicated for manifold (mm) L1 1 Stations L 28 1.5 40 1.5 72 1.5 10 3 60 1.5 72 1.5 104 1.5 4 76 1.5 88 1.5 120 1.5 5 92 1.5 104 1.5 136 1.5 6 108 2.0 120 2.0 152 2.0 7 124 2.0 136 2.0 168 2.0 8 140 2.0 152 2.0 184 2.0 9 156 2.0 168 2.0 200 2.0 2 44 1.5 56 1.5 88 1.5 172 2.0 184 2.0 216 2.0 L2 L3 13-4-31
Coil rated voltage 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 1 2 3 Electrical entry 110 to 120 VAC, 50/60 Hz T E H G Grommet (Lead wire: 300 mm) Grommet (Lead wire: 600 mm) 4 220 VAC, 50/60 Hz 5 6 24 VDC 12 VDC Grommet terminal Conduit terminal D With connector DO Without connector L With lead wire LN Without lead wire LO Without connector M With lead wire MN Without lead wire 7 240 VAC, 50/60
Hardware Configuration 89 EDS file and icon 89 Setting using Logix DesignerTM 89 Configuration assembly 94 Parameter setting of EX600 with configuration assembly 94 Parameter setting of IO-Link device with configuration assembly 107 Configuration assembly setting method example 108 Device Level Ring (DLR) function 111 QuickConnectTM function 111 EtherNet/IPTM Object 113 IO-Link SMI service 120
F MXZ12 MXZ16 160 100 OUT side IN side OUT side IN side 140 0.7/ 80 0.7/ Supply pressure [MPa] Supply pressure [MPa] 120 Pressing force [N] Pressing force [N] 100 0.5/0.67 60 0.5/0.67 80 40 0.3/0.4 0.3/0.4 60 40 20 20 0 0 0 20 40 60 80 0 10 20 30 40 Allowable overhang L [mm] Allowable overhang L [mm] MXZ25 MXZ20 400 250 OUT side IN side OUT side IN side 350 0.7/ 0.7/ 200 Supply pressure [
Note 4) ( ): Dimensions for D-A93. Specific Product Precautions Be sure to read this before handling. Mounting Caution Appropriate tightening torque 1. Observe the proper tightening torque in the right table in mounting.
Internal voltage drop Indicator light (lights when ON) Applications AC DC 24V or less AC DC 48V or less AC DC100V or less 24VDC 100VAC 50mA 40mA 20mA 5 to 40mA 5 to 20mA Relay, PLC, IC circuit D-A90 D-A90V None 0 Relay, PLC D-A93 D-A93V 2.6V or less D-A96 D-A96V 4 to 8VDC 20mA 0.8V or less IC circuit Lead wires D-A90, A93 : Oil resistant heavy duty vinyl cord 2.7 0.18mm x 2 wire (Brown