Refer to back page 50 for Safety Instructions, pages 543 to 546 for Flow Control Equipment Precautions, and pages 573 to 575 for Specific Product Precautions. Metric size 3.2 4 6 8 10 3.2 4 6 8 10 6 8 10 12 10 12 16 Tubing O.D.
A B C D E EE F G H J K Applicable size Y200T-D 3.2 67 29 51 24 33 11.5 5.5 15.5 3.5 30 JSXM20 Y300T-D 4.2 85 42.5 67.5 35 14 7 20 6 41 JSXM30 Y400T-D 5.2 115 50 85.5 40 55 18 9 26 7 50 JSXM40 45 JSX10, 20, 30 Series Table of UL-compliant Products * Refer to the table below for UL-compliant products.
(mm) Stroke range Bore size (mm) I J K M B D C E KA GA GB H 40 50 63 78 92 110 M6 x 1.0 M8 x 1.25 M8 x 1.25 25 25 25 10 14 14 45 55 68 21 26 32 36 46 53 34.5 40 46.5 40 45 50 46 55 66 59 71 82 23.5 28 34.5 to 1000 to 1000 to 1000 Stroke range Bore size (mm) MM XA XL Y ZZ MA MB MC N P S 40 50 63 M6 x 1.0 M8 x 1.25 M8 x 1.25 12 16 16 6 6 6 9.5 12.5 15 178 195 221 16 16 16 12 15 15 44 50 56
16 54 35 6.6 100 70 130 M10 x 1.5 depth 18 65 30 26.5 35 109 75, 100 125, 150 200, 250 300 M6 x 1 depth 12 19 118 80 11 depth 8 35 100 16 16 60 35 6.6 106 80 73 135 M10 x 1.5 depth 18 35 29 40 129 M8 x 1.25 depth 16 22 150 100 14 depth 10 40 120 19 19 75 50 9 134 95 93 170 M12 x 1.75 depth 21 45 32 50 152 M10 x 1.5 depth 20 22 170 120 17 depth 12 45 150 21 25 90 56 11 152 115 103 194 50
121 0.47 14 B XLA-40-2 65 171 1.1 45 XLA-50-2 70 185 1.8 80 XLA-63-2 88 212 3.1 160 A XLA-80-2 90 257 5.1 200 *1 The same for all series Minimal outgassing Low outgassing makes it possible to use a lower capacity pump and also shorten exhaust time.
Coil rated voltage VP7 1 2 3 4 5 6 100V AC (50/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC VP4 VQ VQ4 Wiring Specifications VQZ The lead wires are connected to the valve as shown below. Connect each to the power supply side.
SY100-30-3AS Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Lead wire length U Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
Different sides Same side Different sides Same side D-C7 D-C8 15 50 10 50 + 45 (n 2) 15 + 45 n 2 2 D-H7 D-H7W D-H7BAL D-H7NF (n = 2, 4, 6 ) 60 + 45 (n 2) 15 60 10 Air Release D-C73C D-C80C D-H7C 15 + 50 n 2 2 Caution 15 65 10 (n = 2, 4, 6 ) 65 + 50 (n 2) 1.
M2 m1 M3 30 50 200 m3 Allowable moment (Nm) Allowable moment (Nm) MY1C Load weight (kg) 40 Load weight (kg) Diagonal cam follower 20 45 Lateral cam follower 50 30 100 20 10 10 0 MY2C 0 0 16 25 40 0 16 25 40 16 25 40 16 25 40 Bore size (mm) Bore size (mm) Bore size (mm) Bore size (mm) Diagonal cam follower 60 Lateral cam follower MY2HT MY2H MY1H MY2HT MY2H MY1H MY2C MY1C MY2C MY1C 8-13-2 3
Note 7) The display unit is comformed to CE mark. 4 Series PF2A Flow Characteristics (Pressure Loss) PF2A710,510 PF2A750,550 PF2A711,511 3.0 1.0 10 Pressure loss (kPa) Pressure loss (kPa) Pressure loss (kPa) 2.5 0.8 8 2.0 6 0.6 1.5 0.4 4 1.0 0.2 2 0.5 Flow rate (l/min) 0 100 10 25 50 75 5 2.5 7.5 0 5 10 15 20 25 30 40 35 45 50 0 1 10 Flow rate (l/min) Flow rate (l/min) PF2A721,521 PF2A751,551
50 5 0 Z X Mass and center of gravity of the load 25 Center of gravity 50 Load no.
Note 7) The display unit is comformed to CE mark. 4 Series PF2A Flow Characteristics (Pressure Loss) PF2A710,510 PF2A750,550 PF2A711,511 3.0 1.0 10 Pressure loss (kPa) Pressure loss (kPa) Pressure loss (kPa) 2.5 0.8 8 2.0 6 0.6 1.5 0.4 4 1.0 0.2 2 0.5 Flow rate (l/min) 0 100 10 25 50 75 5 2.5 7.5 0 5 10 15 20 25 30 40 35 45 50 0 1 10 Flow rate (l/min) Flow rate (l/min) PF2A721,521 PF2A751,551
SUP = 0.2 MPa 0.2 0.2 0.2 0.1 0.1 0.1 0 0 0 50 100 150 200 0 Discharge (mL/min) 0 Discharge (mL/min) 200 400 600 800 1000 0 Discharge (mL/min) 200 400 600 800 1000 Air Consumption: Built-in Solenoid Valve/Air Operated Calculation of Air Consumption Air Consumption 45 Find the air consumption for operation with a 5 Hz switching cycle and pilot air pressure of 0.35 MPa from the air consumption
mm) G A C D E F H J K B I Bore size (mm) 32 40 50 63 Standard stroke 64 131 27 16 45 49.5 M14 x 1.5 4.5 14 90 14 50, 75, 100, 125, 150, 175, 200, 250, 300 71.5 177 27 16 52 57 M14 x 1.5 5 14 136 24 100, 125, 150, 175, 200, 250, 300, 400, 500 85.5 200, 300, 500 193 32 20 64 71 M18 x 1.5 7 18 144 22.5 98.5 200, 300, 500 194 32 20 77 84 M18 x 1.5 7 18 145 21 P M N O T X Z L Q Bore size (mm)
200 0 0 0 0 10 20 30 40 50 60 70 0 10 20 30 40 50 0 5 10 15 20 25 30 35 Work load [kg] Work load [kg] Work load [kg] 1000 1000 1000 800 800 800 L4 [mm] L4 [mm] L4 [mm] 600 600 600 L4 X 400 400 400 200 200 200 0 0 0 0 10 20 30 40 50 0 10 20 30 40 50 60 70 0 5 10 15 20 25 30 35 Work load [kg] Work load [kg] Work load [kg] 1000 1000 1000 800 800 800 Mey L5 [mm] L5 [mm] L5 [mm] 600 600 600 m
Solenoid Specifications Apparent power (VA) Inrush Holding Power consumption (W) (Holding) Temperature rise (C ) (Rated voltage) Frequency (Hz) 50 25 12 60 20 8 Model Power source 5 50 3.5 35 6 50 8 55 6.5 45 8 50 0.5 60 9.5 50 11.5 55 Note) They are values in an ambient temperature of 20C 5C and application of rated voltage.
Product weight [kg] Model Stroke Additional weight Size Motor type 50 100 150 with lock 16 T6 2.02 2.41 0.30 25 T7 3.77 4.37 5.77 0.40 -6- 1.2 LECY series driver 1.2.1 How to order L E S Y H 16 D V6 A 50 S 3 M2 (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (3)Motor type (2)Motor mouting position (1) Size Symbol type Output D In-line 16 25 Size Compatible driver [W] R Right side parallel LECYM2
I l 50i 70 , iiFl.r* 0 q . . , . 50 6o ' 3 0 3o , , , . 3 0 , : LXPB5SA 40 40 '" .,1 Slide i Screw \ I i LXPB5SB 2D 2A LXSH2BC 100 50 220 High rigidity linear guide Ball LXSH2BD 100 50 90 Screw LXSH5BC 1 0 0 50 1 6 0 LXSH5BD 1 0 0 50 70 LXSH2SA 90 40 60 Slide LXSH2SB 45 20 30 Screw LXSHSSA 60 20 40 LXSH5SB 30 1 0 20 , \ | '-t 'oo"ot| I PLc I ll'i;!:-,?
0.5MPa 0.5MPa 60 60 Holding force (N) Holding force (N) 50 50 0.4MPa 0.4MPa 40 40 0.3MPa 0.3MPa 30 30 0.2MPa 0.2MPa 20 20 10 10 0 10 30 50 0 10 30 50 70 90 90 70 Holding point L (mm) Holding point L (mm) 2.3-6 Series MHR2/MDHR2 Construction MHR2 !
N.O. 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz Note) N.O. valve operates properly only when appropriate pressure is applied to the pilot.