Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Not Provided, Allowable
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Not Provided, Allowable
Load Mass (Horizontal Mounting)(kg): 10~19, Table Size Length L(mm): 70, Table Material: [Aluminum] Aluminum Alloy, Rodless Cylinder Joint Type: Magnetic, Guide: [Guideless] Prototype, Table Size Width W(mm): 128.5, Table Size Height H(mm): 46, Table Parallelism(µm): 50, Table Surface Treatment: [Anodize] Hard Anodize, Operating Pressure(MPa): 0.2 to 0.7, Environment: General Purpose, Maximum
Load Mass (Horizontal Mounting)(kg): 10~19, Table Size Length L(mm): 70, Table Material: [Aluminum] Aluminum Alloy, Rodless Cylinder Joint Type: Magnetic, Guide: [Guideless] Prototype, Table Size Width W(mm): 128.5, Table Size Height H(mm): 46, Table Parallelism(µm): 50, Table Surface Treatment: [Anodize] Hard Anodize, Operating Pressure(MPa): 0.2 to 0.7, Environment: General Purpose, Maximum
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.820
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.310
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.820, Torque(N⋅m): 10.8
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.820, Torque(N⋅m): 10.8
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.310, Torque(N⋅m): 10.8
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 100, Valves
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 100, Valves
Operation Method: Move Turning, Cylinder Diameter(Ø): 50, Stroke S(mm): 50, Support Type: Head side flange, Rod Tip Shape: Female Thread, Rotation Angle θ: [90°] 90°±10°, Clamping Force(kN): 0.825, Max.
: M9N, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Mount Support: Through-Hole / Both Ends Tapped Common (Standard), Rod Tip Shape: Female rod end, Custom-made Specifications: Low speed cylinder (10 to 50 mm/s)
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Clevis, Port thread type: Rc, Body Options: Rod End Female Thread, Auto Switches:
Pressure(MPa): 1, Additional Function: With Arm, Rotating Direction: Left, Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: M9N, Lead Wire Length(m): 3, The number of the switches: 2, Specification: Built-in magnet, Port Screw Type: G, Made to order specifications: None
Pressure(MPa): 1, Additional Function: With Arm, Rotating Direction: Right, Rod Motion: Double Acting Piece Rod, Operating Temperature Range(°C): -10~60, Auto Switches: M9N, Lead Wire Length(m): 3, The number of the switches: 2, Specification: Built-in magnet, Port Screw Type: G, Made to order specifications: None
Model: 2 (SGC200), Valve Type: 1 (Normally Closed), Seal Material: A (NBR), Pressure Range: 10 (0 to 1 MPa), Thread: N (NPT), Port Size: 10 (3/8), Pilot Valve: Y (0.35 W Type, V116), Voltage: 3 (110 VAC (115 VAC) 50/60 Hz), Electrical Entry: W (M12 Connector, 4-pin Type), Surge Suppressor: Z (With Light and Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Bracket Mounting