SMC Corporation of America
Elite Part Number Search
Search Results "VQ4100-31-02"

VNB 02, 12 (N.O.) In contrast wth the N.C., when the power to the pilot solenoid valve is turned off (or when air is exhausted from the P2 port of the air operated style), the valve is held open by the return spring. When the pilot solenoid valve is energized (or when pressurized air enters through the P2 port of the air operated style), the valve element closes. VNB 03 (C.O.)

L 31 32 33 34 35 36 37 38 39 40 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 No.

common 31 slave mode I iso ated comrnon As.lnlerhce 4in/21'jrt 31 slavE riode I ho aled con',1ron Wnhod Sl unitinpui block {SDo) Nole 1 ) Indimie the size in lt'e specinton sheel n ihe Ese oi CM and L^r Note 2l Symbols ior inch s zes are

33 38 27 29 31 33 38 43 27 29 31 33 38 43 C D Model Mounting bolt CDUJB6-4 -6 -8 -10 -15 CDUJB8-4 -6 -8 -10 -15 -20 CDUJB10-4 -6 -8 -10 -15 -20 Model Mounting bolt CDUJB6-4 -6 -8 -10 -15 CDUJB8-4 -6 -8 -10 -15 -20 CDUJB10-4 -6 -8 -10 -15 -20 A M3 x 27l M3 x 29l M3 x 31l M3 x 33l M3 x 38l M3 x 27l M3 x 29l M3 x 31l M3 x 33l M3 x 38l M3 x 43l M3 x 27l M3 x 29l M3 x 31l M3 x 33l M3 x 38l M3

C4 (EXH) port One-touch fitting for 4 For replacement parts, refer to page 2-4-105. 2-4-31 32 For details about certified products conforming to international standards, visit us at www.smcworld.com.

(When the point table occupies 1 station, a maximum of 31 points are usable. 255 points become usable when 2 stations are occupied.)

Under the New Measurement Law, products for overseas use only (SI unit type for use in Japan). 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 ) ) ) ) ) ) ) ) Options Symbol Description ) ) Nil 1 B With bracket Built-in silencer (EXH port) Handle / Bonnet material Symbol Material S A B Flame resistant PBT 3 Aluminum Built-in silencer A spacer or spacer with bracket is required if the valve is combined

BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other than the above are produced upon receipt of order.

KEA12 KEB12 KEA06 KEB06 KEA08 KEB08 KEA10 KEB10 Without a push button guard With a push button guard Rc thread with a push button guard AS-F Example of circuit diagram (Residual exhaust of air cylinder) Model KEC-03 KEC-02 TMH Applicable tubing O.D. or connection thread 12, Rc 3/8 8, Rc 1/4 14 6 10 2 1 3 2 1 ASD Applicable tubing material Fluid Operating pressure range Ambient and fluid

BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other than the above are produced upon receipt of order.

Blanking plate with 2 screws and gasket L dimension 39 498 38 485.5 37 473 36 460.5 35 448 34 435.5 33 423 32 410.5 31 398 No. 40 510.5 L dimension 4-12-16

Nil N F Rc NPT G OUT 1 IN Port size Symbol 01 02 03 04 06 Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Voltage 1 2 3 4 36 100VAC 200VAC 110VAC 220VAC 230VAC Orifice size Consult P/A regarding other voltages.

PA03 02: LEC-MR-RB-032 03: LEC-MR-RB-12 Set this parameter to enable the absolute position detection system. For details, refer to "LECSN-T Operation Manual, Chapter 12.

Rc NPT G Nil N F OUT(2) 1 IN(1) Port size Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Symbol 01 02 03 04 06 Voltage 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC Orifice size Please consult with SMC regarding other voltages.

Nil N F Rc NPT G OUT 1 IN Port size Symbol 01 02 03 04 06 Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Voltage 1 2 3 4 36 100VAC 200VAC 110VAC 220VAC 230VAC Orifice size Consult SMC regarding other voltages.

L size Blank plate with 2 screws and gasket 39 498 38 485.5 37 473 36 460.5 35 448 34 435.5 33 423 32 410.5 31 398 No. L size 40 510.5 2.9-15

Without switch and filter ZX1-J2 Filter unit (F) ZX1-J2-F 91.2 1 20 11.5 7 41 1 51 8 Bracket B (Standard accessory) (Mounting hole) 2-R1.8 (Mounting hole) 3.6 (Mounting hole) 1 10 19 8.8 4.8 Filter 35.4 (Mounting hole) 1 5.4 M5 (or M6) (V port) Vacuum pad connection port (Mounting hole) 13-2-31 31 Series ZX Ejector System/Manifold Specifications Function Max. number of units 8 units Supply

No Thread IMPERIAL Code : Thread Form 00 : None (No reduction in METRIC Code : Thread Form METRIC Code : Thread Form Code : Thread Form 27 : 3/4-10 60 : M3 x 0.35 88 : M14 x 1.5 piston rod diameter) 28 : 3/4-16 61 : M3 x 0.5 89 : M20 x 1.5 01 : 2-56 29 : 7/8-9 62 : M4 x 0.5 90 : M12 x 1.25 02 : 2-64 30 : 7/8-14 63 : M4 x 0.7 91 : M42 x 1.5 03 : 4-40 31 : 1-8 64 : M5 x 0.5 92 : M24 x 3.0 04

For details, refer to page 8-30-31. 8-10-22 22 Precision Cylinder Series MTS Caution on lnstalling in Close Proximity to Each Other Caution 1. When cylinders are used in close proximity to one another as in mounting patterns (1) through (4), the magnetic force of the auto switch magnets in cylinder B may have an effect on the operation of the auto switches on cylinder A.

No Thread IMPERIAL Code : Thread Form 00 : None (No reduction in METRIC Code : Thread Form METRIC Code : Thread Form Code : Thread Form 27 : 3/4-10 60 : M3 x 0.35 88 : M14 x 1.5 piston rod diameter) 28 : 3/4-16 61 : M3 x 0.5 89 : M20 x 1.5 01 : 2-56 29 : 7/8-9 62 : M4 x 0.5 90 : M12 x 1.25 02 : 2-64 30 : 7/8-14 63 : M4 x 0.7 91 : M42 x 1.5 03 : 4-40 31 : 1-8 64 : M5 x 0.5 92 : M24 x 3.0 04