SMC Corporation of America
Elite Part Number Search
Search Results "XLA-40H0"

None in the Case of No Auto Switch), Number: 2pcs, Valve Open/Closed, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA

Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: N1 [EPDM (2101-80)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA

Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA

Indicator, Flange Side, Temperature: 5 to 60°C, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: 3m, Number: 2pcs, Valve Open/Closed, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: -, Seal Replacement: -, Flange Size Specification: Required for XLA

Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: Standard: External - Hard Anodized; Internal - Raw Material, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal, Exterior Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA

Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: Q1 [KALREZ® (4079)], Seal Replacement: Valve Seal; In Addition for XLD: S Valve Seat Assembly & O-ring for Fixing, Flange Size Specification: Required for XLA

Part Number Description: VALVE SEAL   Product Line: Z   Product Line Description: VACUUM SERIES   Family Code: 681   Family Description: XLA HIGH VACUUM VALVE   Class Code: 21   Part Code: 2   Reference Code:  L   Click here to report information errorImage shown may not match exact part number

Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, EXTERIOR SEAL, XLA 80, Q1 MATERIAL, HIGH VACUUM VALVE, L45, 11.4 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Flange Size: -, Flange Type: -, Port Direction: -, Temperature: -, Version: -, Auto Switch: -, Lead Wire: -, Number: -, Non-standard Indicator: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -

Valve Type: XLD (Smooth Exhaust, Normally Closed, Bellows, O-ring Seal), Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Flange Side; Std. Indicator, Flange Side, Temperature: H0 (5 to 150°C, No Heater)

Variation: A (Normally Closed, Bellows Seal), Flange Size: 40, Indicator, Actuator Port Direction: w/o Indicator, Actuator Port Direction on Flange Side, Temperature Specifications, Heater: H0 (5 to 150°C, w/o Heater)

Type: Pilot Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 40, Seal Type: Bellows Seal, Sonic Conductance: 45L/S, Valve Type: In-line type, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 150, Switch

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: KF, Flange Size Nominal: 40, Seal Type: Bellows Seal, Sonic Conductance: 45L/S, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 150, Switch Part Number: No auto-switch

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: Angle type, Indicator: No indicator, Pilot Port Direction: Flange side, Temperature Range(°C): 5 to 150, Switch Part

Type: Air-Actuated Vacuum Valve, Application: Single Item Operating, Installation Method: Direct, Number of Ports: 2-Port Valve, Switching Type: 2-Position Normally Closed, Piping Opening: Flange, Flange Type: NW, Flange Size Nominal: 40, Seal Type: Bellows Seal, Valve Type: In-line type, Indicator: No indicator, Pilot Port Direction: Flange surface, back, Temperature Range(°C): 5 to 150,

Valve Type: XYA (In-line Type, Normally Closed, Bellows Seal), Flange Size: 40, Flange Type: KF (NW), Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std. Ind.,RearFlangeSide; N/A, Temperature: H0 (5 to 150°C)

Valve Type: XMA (Angle Type, Normally Closed, Bellows Seal), Flange Size: 40, Flange Type: KF (NW), Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std. Ind.,RearFlangeSide; N/A, Temperature: H0 (5 to 150°C)

Valve Type: XYD (In-line Type, 2 State Control, Single Acting, Bellows, O-ring Seal), Flange Size: 40, Flange Type: KF (NW), Port Direction: w/o Ind. or w/Std.Ind.,FlangeSide; w/o Ind or w/Std. Ind.,RearFlangeSide; N/A, Temperature: H0 (5 to 150°C)