SMC Corporation of America
Elite Part Number Search
Search Results "LVM095R-5AP-K-Q"

6 i u q r !1 !0 Closed condition Normally closed !2 !3 !4 Component Parts Material Material Note Note No. q w e No. i o !0 !1 !2 !3 !4 !

0 o i q Note) AS1001F(3.2, 4, 6, 1/8", 5/32", 1/4"), AS2001F(4 , 6, 5/32") are made of POM. 3/16" ,3/8" ,1/2" are made of brass (Electroless nickel plated). Dimensions H1 (Hexagon width across flats) Applicable tubing O.D. d H2 (Hexagon width across flats) L4 L3 L5 D1 L2 M M L1 Metric Size Inch Size L5 L5 L4 Max. L4 Max.

3 @5 q @3 t r u e o y @1 i !7 !1 Component Parts Material NBR NBR Stainless steel Stainless steel POM, Stainless steel (1) Note Description DY seal DY seal Spring Spring Cassette Seal Spacer O-ring O-ring O-ring O-ring Ring Description No. !4 !5 !6 !7 !8 !9 @0 @1 @2 @3 @4 @5 Note Material PBT PBT PBT Brass Brass Brass Brass Brass Brass Brass No. q w e r t y u i o !0 !1 !2 !

Material Note Description Body Needle Bottom cover Handle Component Parts Chromated Aluminum alloy Brass Aluminum alloy Zinc alloy q w e r No. Description Material Note Body Valve guide Check valve Needle Handle Chromated Chromated Rubber lining Chromated Black painted Aluminum alloy Aluminum alloy Brass Brass Carbon steel q w e r t AS Replacement Parts ASP No. Description Part no.

6 i u q r !1 !0 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Closed condition Normally closed !2 !3 !4 Component Parts Material Material Note Note No. q w e No. i o !0 !1 !2 !3 !4 !

6 q r !0 !1 !2 Fingers closed Normally closed !4 !3 Component Parts Component Parts Note Material Material Note No. q w e t y u No. i o !0 !1 !2 !3 !4 !

Relation of Operating Temperature and Maximum Operating Pressure Particulate Generation Grade Classifications 1.2 10 Average particle concentration Particles/ft Grade 4 Max. operating pressure MPa 1.0 10 0.8 Grade 3 10 0.6 10 Grade 2 10 0.4 Grade 1 100.2 0 5 0 20 40 60 1 0.1 0.2 Particle size m or less 0.3 0.5 Operating temperature C 1 Series AS-FPQ/FPG How to Order AS 2 1 1 2 F P Q 01 06

Material Replacement Parts Material Note Component Parts VQZ No. q w e r t y No. !0 !

(Values at the initial period) VG VP JIS Symbol (A) 2 S070 VQ Construction 1 (P) 3 (R) VKF q t o r e VQZ y VZ y VS VFN i w 1(P)2(A)3(R) P R Description Component Parts No. q w e r t y u Note Material Aluminum die-casted Aluminum die-casted Aluminum Resin Stainless steel Steel Solenoid coil assembly Sub-plate Body Spool/Sleeve Manual override Return spring Bracket assembly Gasket assembly

Series: 2 (VQZ2000), Composite Symbol: 1 (2 Position Single), Seal Type: 1 (Rubber Seal), Function: Standard (0.35W DC, AC), Coil Voltage: 5 (24VDC), Lead Wire: YO (DIN Terminal w/o Connector, w/oLight, w/oSurge Suppressor), Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: w/o Sub-plate, Q: Q (CE Marked)

Relation of Operating Temperature and Maximum Operating Pressure Particulate Generation Grade Classifications 1.2 10 Average particle concentration Particles/ft Grade 4 Max. operating pressure MPa 1.0 10 0.8 Grade 3 10 0.6 10 Grade 2 10 0.4 Grade 1 100.2 0 5 0 20 40 60 1 0.1 0.2 Particle size m or less 0.3 0.5 Operating temperature C 1 Series AS-FPQ/FPG How to Order AS 2 1 1 2 F P Q 01 06

uick supply of pressure when the piston reaches the end of stroke Parts in section C provide low pressure on the return stroke of the piston Section B Parts in section B provide q uick exhaust of supply pressure on the return stroke to shorten the delay time Flow valve/ASQ Model Model Applicable tube O.D.

Q,/N.O. +Including armature ass y How To Ord.er Lead qiJe length When ordering the valve and long connector ass'y include both lhe valve and conneetor ass'y producl numbe6.

ltil q{ry 30 (1 3/16) RailTyps DA7 o NCDBA!8363C.A5 & @l w Gommd DA8 ,n e), s63 121t2) 00 {3 1/8), 0100 (a) HailTyp DA5 O D-46 o : Available, X: Nol avilad NCDRAIBW3o-O-A7 Re e d Sw ilc h Spe c ific atio ns [od6l I}472 D{72H tra?t. BATTI D Tdl sr80 , &ttdr &r51 tr56 trt6,w D-lft Rday, Seqlericer lC CircLiil Applc.ton Rlay, Sequenc6r tc Cir!

Input q Insert the electric cables into the cover. w Press with pliers. Input/output 10 seconds for 4 cables. 10 seconds for 4 cables. Output Elimination of branch unit The function of a branch unit is built-in a 16 point unit, allowing reduction of the number of units.

Nylon Urethane M Q L D KCT04-00 KCT06-00 KCT08-00 KCT10-00 KCT12-00 4 6 8 10 12 2.8 2.8 7.6 7.6 13.7 11.1 21.1 19.0 28.3 24.3 18 19 21.5 24 25.5 5.3 6.1 7.1 7.9 8.6 28.6 32.7 39.2 45.5 49.2 10.4 12.8 15.2 18.5 20.9 9 16 24 39 52 Note) D: max. diameter Union Y: KCU Effective orifice(mm 2) Weight (g) Applicable tube O.D. (mm) Part No.

How to Calculate Flow (At an air temperature 20C) 1P1+0.1013<1.89(P2+0.1013) Q=226S P(P2+0.1013) Piping 2P1+0.10131.89(P2+0.1013) 1Completely flush (air blow) pipes before plumbing to remove dust. 2Clamping torgue: Q=113S(P1+0.1013) Q:Flow rate under standard conditions [ /min (ANR)] P1:Upstream pressure (MPa) P2:Downstream pressure(MPa) P:Pressure differential(P1-P2)(MPa) S:Effective area