Body Size: 50, Thread: N (NPT), Port: 06 (3/4), Option: E3 (Output: PNP output / Electrical entry: Wiring bottom entry), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: RZ (R + Z)
Stations: 06 (Stations), Wiring: F (D-sub Connector), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 4 (ø1.5), 1st Selection Supply Valve and Release Valve
Stations: 06 (Stations), Wiring: P (Flat Ribbon Cable Connector), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: N (w/o Pressure Switch for Vacuum/Pressure Sensor), Leadwire: without Leadwire, Unit Options: without Option, 1st Nominal Nozzle Size: 1 (ø0.7), 1st Selection Supply Valve and
Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: N (NPT), Port Size: 06 (3/4), Output Specifications: A (Out 1: NPN; Out 2: NPN)
Stations: 06 (Stations), Wiring: F (D-sub Connector), Manifold Options: BD (with Manifold Options B & D), Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 2 (ø1.0), 1st Selection Supply Valve and
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment
Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: L (-48 kPa), SUP: 06 (One-touch Fitting ø6), VAC: 01 (Screw-in Rc 1/8)
. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: E (Vacuum Break
Body Size: 40, Thread: F (G), Port Size: 06 (3/4), Option: CH (C + H), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Indicator: S, Control Range: M (1 to 50mm/s), Control Method: S (Meter-in), Stud Position: A (Right Side), Tube Diameter: 06 (ø6), Thread: R, Port Size: M5 (M5 x 0.8)
Indicator: S, Control Range: M (1 to 50mm/s), Control Method: S (Meter-in), Stud Position: B (Left Side), Tube Diameter: 06 (ø6), Thread: R, Port Size: M5 (M5 x 0.8)
Indicator: S, Control Range: M (1 to 50mm/s), Control Method: E (Meter-out), Stud Position: B (Left Side), Tube Diameter: 06 (ø6), Thread: R, Port Size: M5 (M5 x 0.8)
Indicator: S, Control Range: M (1 to 50mm/s), Control Method: E (Meter-out), Stud Position: A (Right Side), Tube Diameter: 06 (ø6), Thread: R, Port Size: M5 (M5 x 0.8)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: D (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: G (Instantaneous Flow: gal/min, Accumulated Flow: gal.
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: G (Instantaneous Flow: gal/min, Accumulated Flow: gal.
Control Type: 1 (Meter-in), Applicable Tubing O.D.: 06 (Ø6)
Valve: None; Stop Valve: None, Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm), Light/Surge Voltage
. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 1 (0 to -101 kPa, w/ Unit Selection, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 06 (ø6 One-touch Fitting, Metric)
Body Size: 60, Back Flow: w/o Backflow, Thread: N (NPT), Port Size: 06 (3/4), Mounting Option: Without Mounting, Float Type Auto Drain Option: D (N.O.