L H H L L H H 15 15 Indicator light (Red) Indicator light (Red) 23 23 SE1-01-16/-17 I Z I Z SE1-01-16C/-17C Pressure setting trimmer 2 Pressure setting trimmer 1 Pressure setting trimmer 2 Pressure setting trimmer 1 SET1 SET2 L L H H 15 SET1 SET2 L L H H 15 Indicator light (Red, Green) 23 Indicator light (Red, Green) 23 600 (3000) 56.5 600 (3000) 49 8.5 47 47 3.5 3.5 8.5 2-3.5 Mounting hole
Surface finish Surface finish Ra 10 in. (0.25 m) Standard 25 in. (0.62 m) Code Pressure gauge unit 2) No code Q Unit psig/bar MPa Code No code MPA Ports Porting Configuration Ports 2 ports 3 ports 4 ports Code 2) Pressure gauge unit MPa or psig/bar selectable.
ZFC1l-l-X03 ZFC-EL019 ZFC3l-l-X03 ZFC-EL020 ZFC5l-l-X03 ZFC-EL015 ZFC7l-l-X03 ZFC-EL016 OUT side IN side Symbol -X04 Filtration: 10 m 4 X04 Standard product Filtration: 10 m Replacement Element Part No. (Element: 1 pc.) Series Part no.
12V Relay, PLC Yes Grommet 24 V 3-wire (NPN) F9NW F9NWV 5 V 12 V Diagnosis (2-color indication) IC circuit 3-wire (PNP) F9PW F9PWV F9BW F9BWV 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) M9N 3 m L (Example) M9NL 5 m L (Example) M9NZ Auto switches marked with a symbol are produced upon receipt of order.
12V Relay, PLC Yes Grommet 24 V 3-wire (NPN) F9NW F9NWV 5 V 12 V Diagnosis (2-color indication) IC circuit 3-wire (PNP) F9PW F9PWV F9BW F9BWV 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) M9N 3 m L (Example) M9NL 5 m L (Example) M9NZ Auto switches marked with a symbol are produced upon receipt of order.
Surface finish Ra max 10 in. (0.25 m) Standard 7 in. (0.18 m) 5 in. (0.13 m) Code 0 M V X Specification Standard Sub-atmospheric Code V3 L 1 H 2 4 10 40 -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig 0 to 200 psig 0 to 400 psig 0 to 1000 psig 0 to 4000 psig -0.1 to 0.2 MPa -0.1 to 0.4 MPa -0.1 to 0.7 MPa -0.1 to 1.1 MPa 0 to 1.4 MPa 0 to 3 MPa 0 to 7
1 to 12 stations 24 D side D-sub connector (25P) kit, with 3.0 m cable D side D-sub connector kit D-sub connector (25P) kit, with 5.0 m cable Flat ribbon cable (26P) kit, without cable P kit Flat ribbon cable (26P) kit, with 1.5 m cable 24 stations 1 to 12 stations 24 (1) Flat ribbon cable (26P) kit, with 3.0 m cable D side Flat ribbon cable (26P) kit, with 5.0 m cable 26P 20P ( ) Flat ribbon
Panel mount E Lead wire length 3 m L Panel mount + Front protection cover F Analog Output Suitable model: ZSE50F/ISE50--22/62(L)-(M) Series ISE50 Series ZSE50F Analog output value (V) Analog output value (V) Unit specification 5 5 Note 1) Nil M With unit switching function Note 2) Fixed SI unit 1 1 Note 1) Under the New Measurement Law, which has been in effect since October, 1999, sales
40 50 40 DMGF63 Load weight m0 (kg) Load weight m0 (kg) Load weight m (kg) Load weight m (kg) 30 30 20 -X 20 20 MGF40 MGF40 20MGF40 MGF40 10 10 10 MGF40 Data MGF40 10 5 4 3 5 4 3 2 2 5 5 1 10 20 30 40 50 100 200 300 400 1 5 4 10 20 30 40 50 100 200 300 400 5 10 50 100 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) l = 200 mm l = 300 mm Graph (3) Graph
Grommet L plug connector M plug connector DIN terminal G L M D CE2 ML2B C J G5-S Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.
distance l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5 MPa 100 P = 0.5 MPa Load weight m(kg) Larger than 75st Load weight m(kg) 40 50 100 Larger than 50st 50st 25st 30 25, 50st 20 50 40 10 30 5 4 3 2 20 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 304050 100 200 300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) Allowable side load F(N) 1
(When L/A IN LED is OFF.) (2)Check that the connectors of L/A IN and L/A OUT communication cables are connected and there are no broken wires. L/A IN or L/A OUT LED is OFF. LINK has not yet been established. (3)Keep noise sources away from the communication cable. 11 : The L/A OUT LED will be OFF if the BUS OUT connector is not used.
1500 Flow rate L/min (ANR) Flow rate L/min (ANR) AW20 Rc 1/4 AW40 Rc 1/2 0.6 0.6 0.5 0.5 Outlet pressure MPa Outlet pressure MPa 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 600 800 400 200 0 2000 0 0 1000 3000 Flow rate L/min (ANR) Flow rate L/min (ANR) Pressure Characteristics (Representative value) Conditions: Inlet pressure 0.7MPa; Outlet pressure 0.2MPa; Flow rate 20L/min (ANR) AW10 AW30 AW40-
VCHR 12 2 1 2 1 2 1 1 ITV 2 1 2 1 2 1 2 1 2 1 L 2 2 1 L L L IC AFM AF ARP AFM AF ARP 10 ITVX c Control a clamping force by precise pressure control. d Release residual pressure with the backflow function. Residual pressure circuit Also exhausts residual pressure completely. Sensitivity within 0.2% F.S. allows more precise pressure adjustment. Repeatability within 1% F.S.
SRF 12 2 1 2 1 2 1 1 ITV 2 1 2 1 2 1 2 1 2 1 L 2 2 1 L L L IC AFM AF ARP AFM AF ARP 10 ITVH c Control a clamping force by precise pressure control. d Release residual pressure with the backflow function. Residual pressure circuit Also exhausts residual pressure completely. Sensitivity within 0.2% F.S. allows more precise pressure adjustment. Repeatability within 1% F.S.
min L/min L/min 0 to 0 to 0 to Accumulated flow display/ Set flow range 0 to 999,999,999 L 9,999,9 99.99 x 99,999, 999.9 L 0 to 999,999,999 L 99,999, 999.9 L 0 to 999,999,999 L 103 L Accumulated flow display/ Min. setting unit 1 L 10 L 0.1 L 1 L 0.1 L 1 L Accumulated pulse flow rate conversion value 0.1 0.5 1 2 5 L/pulse 0.05 L 0.1 L 0.5 L 1 L 2 L 0.05 L 0.1 L 0.5 L L/pulse L/pulse L/pulse
(When L/A IN LED is OFF.) (2)Check that the connectors of L/A IN and L/A OUT communication cables are connected and there are no broken wires. (3)Keep noise sources away from the communication cable. L/A IN and L/A OUT LEDs are OFF. LINK has not yet been established. 11 : The L/A OUT LED will be OFF if the BUS OUT connector is not used.
-C X X X X X E ZS-35-D X X ZS-35-F X X X X X + F ZS-35-G X X 1/ 1 ZS-24-A A M35 L,M45 L 2 ZS-24-B B M45 L, 2 ZS-24-D D M35 L,M45 L 2 ZS-35-C (01,N01) ZS-35-D (W1,WF1,M5,C4,C6) ZS-35-F +(01,N01) ZS-35-G +(W1,WF1,M5,C4,C6) -10No.PS-OMM0006CN-E M8(3 ) 01 N M L ISE40A 1/ 2 ISE40A -0.11.000 MPa Y ZSE40A 0.0-101.3 kPa K + T + 1 01 R1/8(M5) N01 NPT1/8(M5) A A D D N NPN1 M8 P PNP1
(LL) 53-SY5 20-LL-01 (-F2) 3 4 5 L (Lead wire length) 156 Insulator: Red (+) Insulator: Black () 5.9 4.1 0.3 mm2 14.7 12 84.3 Terminal type (TT) 53-SY5 20-TT-01 (-F2) 3 4 5 Max. 10 L (Lead wire length) 189.6 Lead wire marking No. 1 (+), No. 2 () 0.75 mm2 101.1 7 Body Ported Series 53-SY5000/7000/9000 Dimensions: 53-SY7000 2-position single L-type plug connector (L) 53-SY7120-L-02 (-F2) With
Particle diameter (m) Particle diameter (m) Front matter 23 Comparison of Cleanliness Standards ISO 14644-1 ISO Cass 1 to 9 Intermediate classes available U descriptor: Particles smaller than 0.1 m M descriptor: Particles larger than 5.0 m Standard Fed.Std.209E British unit: Class 1 to 100.000 SI unit: Class M1 to M7 U descriptor: Particles diameter smaller than 0.1 m (SI unit) (British