H 4 S y m b o l Initial power / Power consumption (W) 100 VAC 200/40 200/50 400/100 200 VAC 800/40 800/50 800/100 Heater assembly number XLA25-60S-1 XLA25-60S-2 XLA25-60S-2 XLA25-60S-3 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc.
MGP(kg) MGPM12100 (mm) (mm) 10 20 25 30 40 50 75 100 125 150 175 200 250 300 350 400 12 MGPM12 0.24 0.28 0.31 0.35 0.39 0.50 0.59 0.70 0.79 0.89 0.98 1.17 16 MGPM16 0.33 0.38 0.43 0.48 0.53 0.68 0.80 0.97 1.09 1.22 1.35 1.60 20 MGPM20 0.67 0.75 0.83 0.91 1.17 1.37 1.57 1.76 1.96 2.16 2.63 3.03 3.42 3.82 25 MGPM25 0.95 1.05 1.16 1.27 1.65 1.92 2.19 2.47 2.74 3.01 3.67 4.21 4.76 5.30 32 MGPM32
Surface finish Ra max 10 in. (0.25 m) Standard 7 in. (0.18 m) 5 in. (0.13 m) Code 0 M V X Specification Standard Sub-atmospheric Code V3 L 1 H 2 4 10 40 -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig 0 to 200 psig 0 to 400 psig 0 to 1000 psig 0 to 4000 psig -0.1 to 0.2 MPa -0.1 to 0.4 MPa -0.1 to 0.7 MPa -0.1 to 1.1 MPa 0 to 1.4 MPa 0 to 3 MPa 0 to 7
Q[l/min(ANR)] = X X 60 X C X D2 X W 4 X 106 (P2 + 0.101) 0.101 Q[l/min(ANR)] = X X 60 X 1 = 841 X 1002 X 200 4 X 106 (0.8 + 0.101) 0.101 Refer to p.1.13-2 for flow rate characteristics table. Select booster regulator size from flow characteristic stable.
Male thread Suitable screw torque (Nm) Hexagonal width (mm) Adjustable spanner nominal (mm) 1/4 4.5 M3 M5 10/32-UNF 100 1/6 8 150 7 to 9 14 1/8 200 12 to 14 17 1/4 200 22 to 24 21 3/8 200 28 to 30 24 1/2 1Nm=10.2kgf/cm Tightening torque for lock nuts Caution qSuitable screw torque for a hexagon lock nut is shown in the table below.
5 1 10 20 30 40 50 100 200 300 400 1 5 4 10 20 30 40 50 100 200 300 400 5 10 50 100 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) l = 300mm Graph 4 l = 200mm Graph 3 v = 150mm/s or less Graph 7 v = 200mm/s or less Graph 8 20 300 300 200 200 MGF100 MGF100 20 100 100 MGF100 10 50 40 50 40 MGF63 MGF100 MGF63 Load weight m0 (kg) Load weight m0 (kg) Load
(mm) Operating direction Piston area (cm2) RHC 1.0 0.7 0.5 0.3 80 56 40 24 0.8 R 12 6 MTS 110 77 55 33 1.1 H 150 105 75 45 1.5 R 16 8 CC 200 140 100 60 2 H 200 139 100 60.8 2 R 20 12 298 208 149 90.2 3 H 370 258 185 112 3.7 R 25 12 490 341 245 149 4.9 H Order Made 600 418 300 182 6 R Made to Order 32 16 800 557 400 243 8 H 1050 731 525 319 10.5 R Refer to the p.5.4-1 regarding made to order
C (+) () Lead wire color Lead wire color B () Reset 100 VAC, 200 VAC 100 VAC, 200 VAC AC Yellow Yellow Set Blue Red A A Single solenoid (AC) Latching solenoid (AC) A Set A Blue Red COM Blue Red SOL. C C SOL. SOL. C COM SOL. Gray Gray Reset Single B C B Reset Latching Note 1) Single: No polarity ON: Orange light lights. Note 2) Setting side energizing: Orange light lights.
In addition, 3 of the wiring types are available with IP65 enclosures. 50 63 80 100 125 140 160 180 200 250 1100 1000 900 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQ5100--04 VQ5101--04 IP65 compatible Enclosure Individual wiring type
74 60 820 263 86 70 0.05 AN300-03 3 8 AN400-04 1 2 0.02 AN500-06 3 4 0.01 AN600-10 1 1 1 0.005 AN700-12 1 4 AN800-14 1 2 AN900-20 0.002 50 200 1000 5000 20 100 500 2000 10 50 10 Construction/Parts/Dimensions Air flow (l/min (ANR)) AN500 to 900 AN200 to 400 Noise Level (Initial conditions) End plate End plate AN200 to 900 Condition: 0.5 MPa at inlet pressure of solenoid valve Measurement
Both Ends Actuation D Double Acting S Spring Heturn T Spring Extend 9/t6" 056 3t4" 075 1-1l16' 106 t-1/2' 150 2" 200 2-1n' 250 3' 300 4" 400 o12 025 037 050 062 075 087 100 Solid State Switch Sboke 125 150 I -t,14" 1/8. 1t4" 3/8' 1f2" 5/8' 94" 1-1f2" I /4' 200 2-1n" 300 350 400 3-1t2" 4' The siandard lead wire length is 0-5m. 'L' is add6d lor 3m. long lead wire.
SET Proceed to the auto shift mode. 16-3-15 15 Series PSE530/200 Operation 3: Special Setting 3 Auto shift Refer to C Auto shift function on page 16-3-17 for details.
C (+) () Lead wire color Lead wire color B () Reset 100 VAC, 200 VAC 100 VAC, 200 VAC AC Yellow Yellow Set Blue Red A A Single solenoid (AC) Latching solenoid (AC) A Set A Blue Red COM Blue Red SOL. C C SOL. SOL. C COM SOL. Gray Gray Reset Single B C B Reset Latching Note 1) Single: No polarity ON: Orange light lights. Note 2) Setting side energizing: Orange light lights.
C (+) () Lead wire color Lead wire color B () Reset 100 VAC, 200 VAC 100 VAC, 200 VAC AC Yellow Yellow Set Blue Red A A Single solenoid (AC) Latching solenoid (AC) A Set A Blue Red COM Blue Red SOL. C C SOL. SOL. C COM SOL. Gray Gray Reset Single B C B Reset Latching Note 1) Single: No polarity ON: Orange light lights. Note 2) Setting side energizing: Orange light lights.
Standard Strokes Bore size [mm] Standard stroke [mm] Max. manufacturable stroke 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 45 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 56 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 63 25, 50, 75, 100, 125, 150
Controller USB cable Communication 120.3 120.3 mm mm 200 200 mm/s mm/s (type A to mini-B) cable 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN3 PC (PC is prepared by the user.) 20 - 4.4 CN4: Counter connector (option) Connect the controller to the Multi-counter (CEU5) using the counter cable (LATH3-). Refer to section 6.2 Counter plug wiring (P.24).
D: Push-turn locking slotted type E: Push-turn locking lever type (With gasket and screws) Body option Nil: Individual pilot exhaust style Electrical entry Grommet L plug connector 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 24, 12 VDC/ 100, 110, 200, 220 VAC 24, 12, 6, 5, 3 VDC M plug connector DIN terminal M8 connector R port P, E port M: Common exhaust for the pilot and main valve MN: Without
Both Ends Actuation D Double Acting S Spring Heturn T Spring Extend 9/t6" 056 3t4" 075 1-1l16' 106 t-1/2' 150 2" 200 2-1n' 250 3' 300 4" 400 o12 025 037 050 062 075 087 100 Solid State Switch Sboke 125 150 I -t,14" 1/8. 1t4" 3/8' 1f2" 5/8' 94" 1-1f2" I /4' 200 2-1n" 300 350 400 3-1t2" 4' The siandard lead wire length is 0-5m. 'L' is add6d lor 3m. long lead wire.
5 1 10 20 30 40 50 100 200 300 400 1 5 4 10 20 30 40 50 100 200 300 400 5 10 50 100 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) l = 300mm Graph 4 l = 200mm Graph 3 v = 150mm/s or less Graph 7 v = 200mm/s or less Graph 8 20 300 300 200 200 MGF100 MGF100 20 100 100 MGF100 10 50 40 50 40 MGF63 MGF100 Load weight m0 (kg) MGF63 Load weight m0 (kg) Load
With light/surge voltage suppressor Types S, Z Types R, U 38 or less 2 position single 33 or less 31 or less 30 or less 2 position double 28 or less 27 or less 56 or less 3 position 50 or less 50 or less Solenoid Specifications Grommet (G), (H), L type plug connector (L), M type plug connector (M), DIN terminal (D) Note 1) Electrical entry 24, 12, 6, 5, 3 DC Rated coil voltage V 100, 110, 200