Note 1) VCA2: 7.5 VA Note) The type with square embedded pressure gauge does not have connection. 879 B
Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
Applicable bore Shock absorber model ML1-A25H ML1-A32H ML1-A40H ML1C25 ML1C32 ML1C40 101 90 25 20 11 72 67.3 12 31 39.5 Max. 16.5 4.5 3 RB1412 120 107 30 25 16 93 73.2 15 38 49 Max. 20 5.5 6 RB2015 147 129 30 31 16 105.5 73.2 15 40.5 54.5 Max. 25 5.5 6 Side Support Side support A 2 x G E E F 2 x H A B Side support B 2 x J A B (mm) A B C D E F G H J Part no.
16 (24) 16 (24) 17 (25) 19.5 (28.5) 24 (36) 24 (36) 32.5 (46.5) 32.5 (46.5) B 20.5 (28. 5) 20.5 (28.5) 21.5 (29.5) 24 (33) 28.5 (40.5) 28.5 (40.5) B 17.5 (25.5) 17.5 (25.5) 18.5 (26.5) 21 (30) 25.5 (37.5) 25.5 (37.5) 34 (48) 34 (48) B 18 (26) 18 (26) 19 (27) 21.5 (30.5) 26 (38) 26 (38) A HS A A A B 19.5 (27.5) 19.5 (27.5) 20.5 (28.5) 23 (32) 27.5 (39.5) 27.5 (39.5) A HS A HS B 15 (22.5) 15
Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com c B part e f d 2.
8 04 1 2 B 11 2B B 20 2B B Options Precautions Be sure to read before handling.
C A External pilot type R (2) B C A Note 1) Option Note 2) For details about external pilot specifications, refer to page 4-14-40.
Catch the hook of the DIN rail bracket on the (b) side on the DIN rail. 2. Push side (a) onto the DIN rail and tighten the clamp screw.
1 4/5 Port Air Operated Valve Series VSA420 Model Flow characteristics P A/B A/B EA/EB Valve model Port size Rc Note) Weight (kg) Body size Pilot port size Function SA C [dm3/(sbar)] 4.2 5.1 5.6 4.2 5.1 5.6 4.1 5.0 5.4 4.3 4.7 5.1 C [dm3/(sbar)] 4.1 5.9 6.5 4.1 5.9 6.5 4.0 6.0 6.6 4.0 5.8 6.4 Cv 0.95 1.3 1.5 0.95 1.3 1.5 0.95 1.4 1.5 0.96 1.3 1.5 b 0.30 0.30 0.33 0.30 0.30 0.33 0.31 0.28
A B Easy manual unlocking Locked Unlocked Locking direction can be selected. Extension lock B A W Retraction lock W A B Various mounting brackets to accommodate wide range of applications.
Pressure gauge port M Q N F J K P E Bracket (option) AR50, 60 Port size Square embedded type pressure gauge (option) A D C L OUT IN G Pressure gauge (option) B Pressure gauge port M N Bracket (option) Q K P F E J Standard specification Accessory specification With pressure gauge Bracket mounting size Panel mount Model Port sizes A 25 40 53 53 70 75 90 95 J 25 30 30 41 50 50 70 70 B 58 94
Motor mounting process M5 x 14 Tightening torque 4.4Nm0.2Nm M4 x 14 Tightening torque 2.1Nm0.1Nm Plate A M4 x 14 M4 x 12 B 22 22 B section detail A section detail 18 Electric Actuator/Maintenance Guide 3 Be sure to read before handling. Belt mounting procedure Belt mounting process Belt mounting process 1. Confirm that the belt to be used has the following part number.
(B) Within the acceptable range (Seats correctly).
8370: JIS B 8361: JIS B 9960-1: -1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4
Description Material q w e r t Solenoid coil IN Armature assembly Stainless steel, HNBR, PPS Return spring Stainless steel O-ring HNBR Body Aluminum Bracket Assembly Dimensions J 1.5 A C 4-6 B D Valve mounting screws 2-H Valve mounting hole Bracket Mounting Dimensions/Bracket Material: Stainless Steel (mm) A B C D H J Assembly part no.
Vacuum pressure Suction flow rate 13-5-5 6 Series ZH Box Type (Built-in silencer): ZHB -S L One-touch connection Applicable tubing diameter B Model A 60 6 22 16 12.8 28 5 47 60 6 22 16 12.8 28 5 47 60 6 22 16 12.8 28 5 47 60 6 22 16 12.8 28 5 47 63 6 23 18 12.8 29 5 50 63 6 23 18 12.8 29 5 50 78 8 27.5 23 13.7 35 7 61 78 8 27.5 23 13.7 35 7 61 B C D E F G H ZH05BS-06-06 ZH05BL-06-06 ZH07BS
B 23.5 A 7.0 B A 10.5 (13.0) B Bore size 50 63 80 23.5 19.5 25.5 12.5 25.5 14.5 25.5 10.5 21.5 14.0 (16.5) 39.5 19.5 39.5 21.5 39.5 17.5 35.5 21.0 (23.5) The values inside ( ) are for the D-A96/A96V.
Single clevis MUC25SMU25, #5 (#1+#5+#11) MUC32SMU32, #5 (#1+#5+#11) MUC40SMU40, #5 (#1+#5+#11) MUC50SMU50, #5 (#1+#5+#11) MUC63SMU63, #5 (#1+#5+#11) 2.4-5 Plate Cylinder/Double Acting Double Rod Series MUW 20, 32, 40, 50, 63 How to Order Standard MUW B 25 30 D M MDUW B 25 30 D M A73 S With auto switch Built-in magnet Number of auto switches 2 1 n Double rod S n Mounting B L F Basic Foot
B Released SET Work 1 Work 2 Work n Atmosphere Max. A: Maximum pressure value when workpiece is adsorbed. A B 4 ON = A A B 4 SET OFF = B + Min. B: Minimum pressure value when workpiece is not adsorbed. OUT1 auto preset For adsorption verification: In this mode, repeat the adsorption and release of the workpiece for a few times. The optimum values will be set automatically.
When performing the piping work, turn the tightening tool in the horizontal direction to the hexagon across flats of the body B so that any moment is not applied to the body A. If the tool is in contact with the body A, this may cause the body B to come off.