Voltage AC125V 2 2 4 4 15 10 15 10 AC250V 1.5 1.5 3 3 15 10 15 10 DC8V 1.5 2.5 3 5 15 15 15 15 DC14V 1.5 2.5 3 5 15 10 15 10 DC30V 1.5 2.5 3 5 6 5 6 5 DC125V 0.3 0.05 0.3 0.05 0.5 0.05 0.5 0.05 DC250V 0.2 0.03 0.2 0.03 0.25 0.03 0.25 0.03 JIS Symbol Construction Precautions Component Parts Be sure to read before handling.
(Produced upon receipt of order) Note 2) Minimum stroke available without auto switch or with one auto switch is 15 mm and minimum 25 mm for with 2 auto switches. Note 3) For 2 or more auto switches with stroke less than 25 mm (minimum 15 mm), consider -X431 (2 switch rails).
) 4 47 42 (Non-locking) Manual override VlA 30 24.5 37 23 20 3 11.5 3.5 4 11 2.6 2(Mounting holes) 18 (Piping port) 4-Rc(PT)1/8 19.5 46.5 25 SlA 1.8 (Bleed port) With filter (80 Mesh) 2.3 46.5 33.5 21.5 5-M5 X 0.8 (Piping port) VlA 8.5 6 6 15 17 17 24 32 R1 P 45.5 1.8 (Bleed port) With filter (80 Mesh) R2 21 VM/VR VH 2 position double: SYJA5220-M5 2 position double: SYJA5240-01 (Mounting
0.8 to 37.1 1.8 to 92.7 4 to 186 8 to 371 Instantaneous CFM x 10-2 CFM x 10-2 CFM x 10-2 CFM x 10-2 Setting/Display flow range flow CO2 0.8 to 18.5 1.8 to 46.3 4 to 93 8 to 185 CFM x 10-2 CFM x 10-2 CFM x 10-2 CFM x 10-2 Min. setting/display unit 0.1 CFM x 10-2 0.1 CFM x 10-2 1 CFM x 10-2 1 CFM x 10-2 Accumulated Setting/Display flow range 0.0 to 9.0 0.0 to 9.9 0 to 9 0 to 9 ft3 x 10-1 ft3
Therefore, SMC products cannot be used for business or certification ordained by the metrology (measurement) laws of each country. -3- 1Specification High performance Battery-less absolute encoder LESYH*(D,R,L)G* LESYH LESYH LESYH LESYH LESYH LESYH LESYH Model 8*GA 8*GB 8*GC 16*GA 16*GB 25*GA 25*GB Stroke[mm] 50,75 50,100 50,100,150 Max.work load[kg] 2 8 12 Horizontal Vertical 1.5 3 6 6
SRF 12 2 1 2 1 2 1 1 ITV 2 1 2 1 2 1 2 1 2 1 L 2 2 1 L L L IC AFM AF ARP AFM AF ARP 10 ITVH c Control a clamping force by precise pressure control. d Release residual pressure with the backflow function. Residual pressure circuit Also exhausts residual pressure completely. Sensitivity within 0.2% F.S. allows more precise pressure adjustment. Repeatability within 1% F.S.
No.MH*-OMY0001 / / MHM-16D* MHM-25D* MHM-32D* MHM-50D* 1. 2. 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8 3. 4. 5. 5-1 5-2 5-3 -2- (ISO/IEC) (JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements)
A unit label is attached. 67 2 settings PNP open collector 2 outputs 2: Fixed unit: MPa Option Part no.
Value/Range SetPoint1 bit(16) 16 bit 3 Y 3 1 R/W 0x003C BDC1 2 R/W SetPoint2 bit(0) 16 bit 3 Y 3 (60) Logic bit(24) 8 bit 0 Y 4 1 R/W 0x003D 2 R/W Mode bit(16) 8 bit 0 Y 5 BDC1 (61) 3 R/W Hysteresis bit(0) 16 bit 10 Y 1 to 400 SetPoint1 bit(16) 16 bit 3 Y 3 1 R/W 0x003E BDC2 2 R/W SetPoint2 bit(0) 16 bit 3 Y 3 (62) Logic bit(24) 8 bit 0 Y 4 1 R/W 0x003F 2 R/W Mode bit(16) 8 bit 0 Y 5 BDC2
Specialty Regulators NAR Series Pressure Regulator NAR425, 435, 625, 635, 825, 835, 925, 935 s n o i t a c i f i c e p S l e d o M 5 2 4 R A N 5 3 4 R A N 5 2 6 R A N 5 3 6 R A N 5 2 8 R A N 5 3 8 R A N 5 2 9 R A N 5 3 9 R A N e z i S t r o P 2 / 1 8 / 3 4 / 1 1 4 / 3 2 / 1 1 4 / 1 1 2 ) a P M ( g i s p e r u s s e r p f o o r P ) 5 . 1 ( 0 2 2 e r u s s e r p g n i t a r e p o . x a
System error (Er5, 6, 7, and 8) is indicated. (1)Bring the pressure back (1)Check if the pressure gets over within the set pressure range. the upper limit of the set pressure range. 6 The display Applied pressure is over the upper limit (---). (2)Take measures to prevent shows "---". (2)Check if foreign matter got into foreign matter from getting into the piping.
If a moment or torque directly acts on the cylinder, it will lead to reduced service life or damage to machinery. 7 3 Position Cylinder Series RZQ Construction 13 24 21 3 2 1 6 4 8 7 10 19 22 20 12 23 11 9 5 23 18 14 16 17 15 22 Parts list No. 1 2 3 4 5 6 7 8 9 10 11 12 No. 13 14 15 16 17 18 19 20 21 22 23 24 Note Note Description Material Description Material Hard anodized Aluminum alloy
L O L ZX G H F K ZR J ZM ZH E D I A ZU B C Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZL 2-4.5 ZY ZQ A B C D E F G H I J K L Model 4 ZFC100-04 ZF 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 ZP 1/4" ZFC101-07 6 ZFC200-06 ZCU 8 ZFC200-
Warning 6. Test run (2)Test run details gradually. 5. Wiring
7 A*8 201 2~200L/min 8 2 (11) S () C8 8(5/16") *6 02*1 Rc1/4 M SI*7 N02*1 NPT1/4 6 F02*1 G1/4*2 SI 1 2ISO1179-1 7:L/min :L 1 (11) L*3 3 OUT1 OU2 A NPN NPN B PNP PNP C NPN (1~5V) D NPN (4~20mA) E*4 PNP (1~5V) F*4 PNP (4~20mA) G*4 NPN *5 H*4 PNP *5 4 5 -10No.PF-OMO0004CN-E 1 W N (2 m) (2 m) + () 2 R S () () T V () () -11No.PF-OMO0004CN-E / ZS-33-D 2m ZS-33-F ZS-33-J (
If the difference between Set point 1 and Set point 2 is less than "6% of maximum rated flow", the maximum Set value of hysteresis is (Set point 1 Set point 2) divided by 2. 2: When Set point 1 = Set point 2, chattering may occur. -19No.PF-OMG0010-H Function selection mode Function selection mode In measurement mode, press the button, to display [F_0].
Compact Slide 6, 10, 16, 20 MXH Series RoHS MXH MXH How to Order MXS MXQ 10 M9BW MXH Z 60 MXQ MXF Made to Order Refer to page 20 for details. Compact Slide MXW Bore size Number of auto switches MXJ 6 mm 10 mm 16 mm 20 mm 6 10 16 20 Nil S 2 pcs. 1 pc. MXP MXY Auto switch MTS Without auto switch (Built-in magnet) Nil For applicable auto switch model, refer to the table below.
CY1L32-PS-N CY1L40-PS-N Piston seal NBR Set of left nos. #7, #8, #9, $0, $1, $2 Scraper NBR 6: Not available Note 1) Seal kit includes #8 to $1 for 6. #8 to $2 are for 10. #7 to $2 are for 15 to 40.
wire 12V 24V Connector Diagnostic indication (2-color indication) Grommet 3-wire (NPN) 5V,12V IC circuit Grommet 3-wire (PNP) 12V 2-wire Connector 3-wire (NPN) Diagnostic indication (2-color indication) IC circuit Relay, PLC 5V,12V 3-wire (PNP) 24V Yes Grommet 12V Water resistant (2-color indication) 2-wire With diagnostic output (2-color indication) Magnetic field resistant (2-color