or less 2 position single 2 position single/double 10 5 5 Max. operating frequency Hz 10 or less 10 or less 13 or less 2 position double 3 position 3 3 3 15 or less 16 or less 20 or less 3 position Non-locking push type, Slotted locking type, Knob locking type SY5000 Manual override Response time ms (at 0.5MPa) Main valve/pilot valve common exhaust type Pilot exhaust Type of actuation Without
Minimum Stroke for Auto Switch Mounting (mm) D-M9 10 D-M9V 5 D-M9W 15 D-M9WV 10 D-A9 10 D-A9V 5 Number of auto switches mounted Bore size (mm) 32 1, 40 50 2, 63 1 10 5 15 15 10 10 2 1 The outline dimensions for 5 mm stroke will be the same as those for 10 mm stroke. 2 The outline dimensions for 10 mm stroke will be the same as those for 15 mm stroke. 7 Prior to Use Auto Switches Common Specifications
9 1/2 15 to 30 14 to 15 2) The gasket can be reused up to 6 to 10 times.
Dimension table Unit: mm Model A B D2 E D1 -0.016 -0.043 12f8 15 7 11 52.8 MHZ2-10 -0.016 -0.043 16f8 20 10 15 58.7 MHZ2-16 -0.020 -0.053 20f8 22 12 19 70.5 MHZ2-20 -0.020 -0.053 25f8 25 15 24 82.9 MHZ2-25 Other dimensions and specifications correspond to the standard type.
/LEHZ .10 2.1 LEHZ () . 10 2.1.1 . 10 2.1.2 . 11 2.1.3 . 12 2.2 LEHZJ () . 13 2.2.1 . 13 2.2.2 . 14 2.2.3 . 15 2.2.4 . 16 3./LEHF .17 3.1 . 17 3.2 . 18 3.3 . 19 4.
Standard stroke (mm) 10, 20, 30, 40, 50 10, 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 75 Bore size (mm) Nil S 6 10 10, 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 75, 80, 90, 100 15, 20, 25, 32 Auto switch type Nil Without auto switch (built-in magnet) Note) Refer to the table below for auto switch part numbers. Applicable auto switches Load voltage Auto switch part no.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Voltage 2 2 4 4 15 10 250 VAC 1.5 1.5 3 3 15 10 8 VDC 1.5 2.5 3 5 15 15 14 VDC 1.5 2.5 3 5 15 10 30 VDC 1.5 2.5 3 5 6 5 125 VDC 0.3 0.05 0.3 0.05 0.5 0.05 250 VDC 0.2 0.03 0.2 0.03 0.25 125 VAC 15 15 15 15 6 0.5 0.25
15 20 25 32 10, 20, 30, 40, 50 Vacuum suction type Relief type M5 x 0.8 10, 20, 30, 40, 50, 75, 100 1/8 Double acting (Both sides) Non-lube 10-/12-/21-CXS6 6 single rod 10-/12-/21-CXS10 10-/12-/21-CXS15 10-/12-/21-CXS20 10-/12-/21-CXS25 10-/12-/21-CXS32 10, 20, 30, 40, 50 10 15 20 25 32 M5 x 0.8 10, 20, 30, 40, 50, 75, 100 1/8 Specifications Suction flow rate of vacuum suction type (Reference
B 11 17.5 1 (Bleed port) VA 1.5 A B M3 x 0.5 (Piping port) 1.5 1.5 33 36 SA Manual override B P R R (35) 7 7 36 (2) VA 7 (13.5) 28.5 15 A 1 (Bleed port) 21 R2 P R1 13 VM Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4 8.2 15 10 10 10 M5 x 0.8 (Piping port) 11 14
Bore size (mm) Z DA DB DL DU DC DX DE DR DO DT DS DH Z DD H10 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.084 0 +0.084 0 32 40 50 63 80 100 32 40 50 63 80 100 6.6 6.6 9 9 11 11 46 52 65 75 95 114 32 32 43 43 64 64 22 22 30 30 45 45 10 10 11.5 11.5 14 14 44 44 60 60 86 86 14 14 20 20 30 30 62 62 81 81 111 111 15 15 18 18 22 22 7 7 8 8 10 10 33 33 45 45 65 65 154 158 182 182 228 228 10 10 14 14
19.8 32.5 27 50 52 Mounting surface position D 0 0.05 d 12.5 (Cylinder stroke) Q Q SR 10 (Clamp stroke) K Port side A C 120 Mounting surface 8 to 10 26 14.5 85.5 12 48 67 10.5 (79) Port side B Mounting surface Diamond cut shape (Guide pin dia.: 9.5 or more) MK Port side MK2T C 100 Mounting surface 1470.1 CK1 Mounting surface CLK2 D (253) Port side CLKG 300.05 20 15 15 CKQ CLKQ Clamp arm
60 44 18 25 14 17.5 M8 x 1.25 18 10 20 M14 x 1.5 30 1/4 37 114 11 17 15 50 50 73 R0.5 M10 x 1.5 25 9 73 53 20 28 17 17 20 10 22 M16 x 1.5 30 3/8 43 116 11 19 15 63 55 80 R0.5 M10 x 1.5 28 8 80 60 22.4 30 17 17 22 10 25 M18 x 1.5 30 3/8 47 120 11 21 15 80 65 90 R2.5 M12 x 1.75 32 8 100 75 28 32 22 20 26 13 29 M22 x 1.5 35 1/2 57 132 11 26 25 100 80 100 R2.5 M12 x 1.75 38 6.5 118 90 35.5 35
Cable length Suffix 05 10 15 20 Nil C Extension cable 5 m Extension cable & connector 10 m 15 m 20 m Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.
6 Special resin MYA63-15-R6659 MYA40-15-R6658 MYA25-15-R6657 MYA16-15-R6656 Scraper !
Cable length Suffix 05 10 15 20 Nil C Extension cable 5 m Extension cable & connector 10 m 15 m 20 m Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.
M5 Nylon Urethane KGT04-M5 KGT04-01 . 15.5 M5 0.8 14 22 15.5 23 13 3.5 4.3 4.3 7 9.5 1 8 4 13 M5 0.8 14 10 10 18 10.4 6.0 6.0 16 1 4 KGT04-02 26 25 19 4.2 13 KGT06-M5 KGT06-01 15 23 17.5 14 25.5 16 4.3 4.3 11.5 7 . 1 8 10 6 10 20 12.8 1 4 KGT06-02 27 27.5 17 17 14 13.9 13.9 21 3 8 KGT06-03 29 29 35 1 8 1 4 KGT08-01 KGT08-02 24.5 28.5 28 30 12 15 23 R(PT) 8 14 15.2 18.5 26.3 18.2 12 23 3 8
25 25 19.5 27 32 32 37 37 10 (12) 40 71 (79) 113 (121) 15 (16) 5.5 6 7 7 10 10 M5 X 0.8 Depth 8 35.5 44 55 69 80 10 (11) M8 X 1.0 Up to 300 301to450 28.5 20 10 (13) 50 78 (87) 130 (139) 15 (16) 10 (12) M6 X 1 Depth 12 M10 X 1.25 Up to 300 301to800 33 20 12 (14) 58 150 (162) 17 (18) 12 (13) M12 X 1.25 M8 X 1.25 Depth 16 90 (102) Up to 300 301to1200 40.5 20 12 (14) 58 150 (162) 17 (18) 22
IZF 21 IZF 31 Rapid static neutralization Installation distance and discharge time (Discharge time from 1000 V to 100 V) IZF21 IZF31 20 20 IZF21 IZF21 IZF31 IZF31 20 20 20 20 15 15 Discharge time [s] Discharge time [s] 15 15 15 15 Air flow level: 1 Discharge time [s] Discharge time [s] Discharge time [s] Discharge time [s] Air flow level: 1 Air flow level: 1 Air flow level: 1 10 10 Air flow
L 60.5 3 48 2 85.5 5 73 4 110.5 7 98 6 135.5 9 123 8 160.5 11 148 10 185.5 13 173 12 210.5 15 198 14 235.5 17 223 16 19 248 18 20 260.5 VP7 285.5 21 273 No.
Note 5) Cables are not included. 15 - 3.2 2 Parts description Details of the parts of the controller. (1) (2) (3) Remove the housing. (10) (8) (4) (5) ON (6) ON (7) OFF 1 2 3 4 5 6 (9) Pulse input signal switch (default) No.