distance (mm) Positioning distance (mm) 100 100 50 10 1 50 10 1 10 10 10 10.1 5.1 1.1 0.2 5.1 1.1 0.2 Speed (mm/s) Speed (mm/s) 2.6 40 40 2.6 1.3 0.3 0.1 1.3 0.3 0.1 1.3 80 80 1.3 0.7 0.2 0.1 0.7 0.2 0.1 Refer to page 303 for acceleration time. 213 Direct Acting Guide 5 Phase Stepper Motor Low Profile Slide Table Type Ball Screw Series LXF Without Motor Brake 8mm/6mm lead How to Order LXFH5 SA
Ejector stations Port & silencer position 1 station 01 Right side Left side Both sides R L S 10 stations (Max.) 10 Note) Left and right as viewed with the VAC port in front Thread type Common exhaust port size 1/2 3/4 ZZMA dedicated silencer (ZZM-SA) 04 06 S Rc NPTF G Nil T F When placing an order, include the single type ejector models to be manifolded together with the manifold part
The method for measuring the overshoot amount can be selected from the separate axis setting. 1pulse Digital waveforms SON, LSP, LSN, TL, TL1, PC, RES, CR, ST1, ST2, EMG, MD0, DOG, OVR, TSTP, TP0, TP1, CDP, TCH, MD1, SIG, SP0...SP2, DI0...DI7, D1, D2, D3 and D4 (Note 1) RD, SA, ZSP, TLC, INP, WNG, ALM, OP, MBR, DB, BWNG, CPO, ZP, POT, PUS, CDPS, ABSV, MEND, PT0...PT7 (Note 1) D1, D2, D3 and
min (Note 1) 22 Speed command (by 0.1 r/min) The speed command to be given to the motor is displayed. 0.1r/min (Note 1) 23 Torque command Control the torque at the torque control or stopper control. 0.1% (Note 1) 24 Speed limit Control the speed at the torque control or stopper control. 1r/min (Note 1) Digital waveforms CSON, PC, EMG, EM1, CDP, CSV3 (Note 1), D1, D2, D3, D4 (Note 2) RD, SA
The method for measuring the overshoot amount can be selected from the separate axis setting. 1pulse Digital waveforms SON, LSP, LSN, TL, TL1, PC, RES, CR, ST1, ST2, EMG, MD0, DOG, OVR, TSTP, TP0, TP1, CDP, TCH, MD1, SIG, SP0...SP2, DI0...DI7, D1, D2, D3 and D4 (Note 1) RD, SA, ZSP, TLC, INP, WNG, ALM, OP, MBR, DB, BWNG, CPO, ZP, POT, PUS, CDPS, ABSV, MEND, PT0...PT7 (Note 1) D1, D2, D3 and
An excessive error alarm will occur when margin is 0 pulse. 1pulse Digital waveforms CSON, PC, RES, CSV1, CSV2, CTL1, CTL2, EMG, EM2/1, CRDY, CDP, CLD, CABS, CZCT, CRSTP, CSV3, D1, D2, D3, D4 (Note 2) RD, SA, ZSP, TLC, VLC, INP, WNG, ALM, OP, MBR, DB, BWNG, ALM2, RDY, STO, SMPD, CDPS, CLDS, ABSV, IPF, SPC, MTTR, SSV1, SSV2, STL1, STL2, ZPASS, SABS, SABSE, FLS, RLS, DOG, SSV3 (Note 1) It is
Body Size: 40, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: M (SI Units Only)
Both types include an isolation valve and can be configured as remotes (SA) or as fieldbus connected bases (EN, PN). The hubs have an extra IO link port for connection to additional devices that can communicate through the system.
Both types include an isolation valve and can be configured as remotes (SA) or as fieldbus connected bases (EN, PN). The hubs have an extra IO link port for connection to additional devices that can communicate through the system.
Both types include an isolation valve and can be configured as remotes (SA) or as fieldbus connected bases (EN, PN). The hubs have an extra IO link port for connection to additional devices that can communicate through the system.
Body Size: 60, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator
Body Size: 60, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only
Body Size: 40, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type)
Body Size: 40, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 40, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 40, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X101 (Regulator and Hub only)
Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: E (Push-turn Locking Type, Manual)
Body Size: 60, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: E (Push-turn Locking Type, Manual)
Both types include an isolation valve and can be configured as remotes (SA) or as fieldbus connected bases (EN, PN). The hubs have an extra IO link port for connection to additional devices that can communicate through the system.
Bore: 25mm, Thread: Rc, Piping: Standard Type, Stroke: 150mm, Stroke Adjustment Unit: SA (Left: w/o Unit; Right: w/Adjustment Bolt), End Lock Position: w/o End Lock