125, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: A44
Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet, Port thread type: NPT, Auto Switches: A44
Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 450mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: A44--Reed, DC Volt >5 <24, AC Volt <200, LED, DIN, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: A44--Reed, DC Volt >5 <24, AC Volt <200, LED, DIN, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 600mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: A44--Reed, DC Volt >5 <24, AC Volt <200, LED, DIN, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: A44--Reed, DC Volt >5 <24, AC Volt <200, LED, DIN, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Single Clevis, Style: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 450mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: A44--Reed, DC Volt >5 <24, AC Volt <200, LED, DIN, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Rod Flange, Bore Size: 50mm, Stroke: 150mm, Rod Boot: Nylon Tarpaulin, Pivot Bracket: None, Rod End Bracket: None, Lead Wire or Prewired Connector: -, Number: -, Auto Switch: A44--Reed, DC Volt >5 <24, AC Volt <200, LED, DIN
Magnet: Built-in, Mounting: Double Clevis, Bore Size: 50mm, Stroke: 75mm, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Lead Wire or Prewired Connector: -, Number: -, Auto Switch: A44--Reed, DC Volt >5 <24, AC Volt <200, LED, DIN
Magnet: Built-in, Mounting: Double Clevis, Bore Size: 50mm, Stroke: 75mm, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc., Auto Switch: A44--Reed, DC Volt >5 <24, AC Volt <200, LED, DIN
Magnet: Built-in, Mounting: Double Clevis, Bore Size: 100mm, Stroke: 350mm, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Lead Wire or Prewired Connector: -, Number: -, Auto Switch: A44--Reed, DC Volt >5 <24, AC Volt <200, LED, DIN
Magnet: Built-in, Mounting: Rod Flange, Bore Size: 100mm, Stroke: 1000mm, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Lead Wire or Prewired Connector: -, Number: -, Auto Switch: A44--Reed, DC Volt >5 <24, AC Volt <200, LED, DIN
Magnet: Built-in, Mounting: Center Trunnion, Bore Size: 80mm, Stroke: 100mm, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Lead Wire or Prewired Connector: -, Number: -, Auto Switch: A44--Reed, DC Volt >5 <24, AC Volt <200, LED, DIN
Magnet: Built-in, Mounting: Rod Flange, Bore Size: 50mm, Stroke: 125mm, Rod Boot: Nylon Tarpaulin, Pivot Bracket: None, Rod End Bracket: None, Lead Wire or Prewired Connector: -, Number: -, Auto Switch: A44--Reed, DC Volt >5 <24, AC Volt <200, LED, DIN
Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~1.0, Cushion: With cushions on both sides, Specification: Built-in magnet, Support bracket: Axial foot type, Port thread type: Rc, Auto Switches: A44
Although auto switches satisfy IEC standard IP67 construction expect some models (D-A3, A44, G39, K39, RNK, RPK) do not use auto switches in applications where continually exposed to water splash or splay. This may cause improper insulation or malfunction. 3. Do not use in an environment with oil or chemicals.
Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~1.0, Cushion: With cushions on both sides, Specification: Built-in magnet, Support bracket: Axial foot type, Port thread type: Rc, Auto Switches: A44
Magnet: Built-in Magnet, Mounting: Double Clevis, Bore Size: 80mm, Thread: Rc, Stroke: 800mm, Rod Boot: None, Cushion: Air Cushion, Pivot Bracket: No Bracket, Rod End Bracket: No Bracket, Auto Switch: A44--Reed, DC Volt >5 <24, AC Volt <200, LED, DIN, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Basic, Bore Size: 80mm, Thread: Rc, Stroke: 600mm, Rod Boot: None, Cushion: Air Cushion, Pivot Bracket: No Bracket, Rod End Bracket: No Bracket, Auto Switch: A44--Reed, DC Volt >5 <24, AC Volt <200, LED, DIN, Lead Wire or Prewired Connector: -, Number: -, Made to Order: -
CYL, TMS, AUTO-SW, AW=D-A44(2). ACTUATOR. 40MM ACNL DOUBLE-ACTING. 6.97237 lb. MD.