Connection thread L1 A Width across flats H1 Connection thread KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 1 1.5 2 2.5 R 1/4 R 1/4 R 1/4 R 1/4 14 14 14 14 31.4 31 30.5 30.1 25.4 25 24.5 24.1 K D H1 A M L1 H D High efficiency nozzle: KNH (mm) Model Nozzle size D Connection thread L1 A Width across flats H1 MS Connection thread Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco
fittings: IN 8, OUT 6) Condition: Inlet pressure 0.5 MPa 0.35 0.7 Outlet pressure (MPa) Outlet pressure (MPa) 0.30 0.6 0.25 0.5 0.20 0.4 0.15 0.3 0.10 0.2 0.05 0.1 0 0 50 100 150 250 200 0 0 50 100 150 200 250 Flow rate L/min (ANR) Flow rate L/min (ANR) Pressure Characteristics (Representative Value) ARM5AA1-308 Outlet pressure 0.2 MPa Flow rate 20 L/min (ANR) Condition: Inlet pressure 0.7
3 55.5 344 487 145 90 150 500 20 430 470 1 1 1 2 175 87.5 30 62.5 4 1 639 639 639 416.5 48 250 125 33.2 33.2 250 250 125 639 230 120 227 2 1 1055 ALD600/900 Series Related Products: Strainer At the terminal of an air pressure line in which a D.P.
U side mounting D U 1 2 8 stations Option D side 3 4 3 4 Max: 8 stations Refer to page 3-5-8.
For details, refer to page 443. 413
CHA Series How to Mount and Move the Auto Switch
Note) (N)AM AM Japanese NAM North American H O W T O O R D E R M I S T S E P A R AT O R S E R I E S (N)AM (N)AM S U B-S TA N D A R D S P E C I F I C AT I O N S B O D Y S I Z E Y Drain Guide 1/4 Internal Thread M With Drain Lock M5 Screw R IN, OUT Reverse Direction 150 1/8 Basis 250 1/4 Basis 350 3/8 Basis 450 1/2 Basis 550 3/4 Basis 650 1 Basis 850 1 1/2 Basis O P T I O N S None B Bracket
-X 663 CE1 Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height D-A9V D-M9V D-M9WV D-M9AV D-A9 D-M9 D-M9W D-M9A 12 to 20 25 U B A 32 to 63 D-A9 D-M9 D-M9W D-M9A D-A9V D-M9V D-M9WV D-M9AV U D-A7 D-A80 D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F79F D-F7NT D-F7BA D-A73C D-A80C D-J79C D-A79W D-F7WV D-J7V D-F7BAV 12 to 20 U B A 32 to 63
PF2MC7501 Item Default settings [P_1] Set value of OUT1 250 L/min [H_1] Hysteresis of OUT1 25 L/min [P_2] Set value of OUT2 250 L/min [H_2] Hysteresis of OUT2 25 L/min PF2MC7102 Item Default settings [P_1] Set value of OUT1 500 L/min [H_1] Hysteresis of OUT1 50 L/min [P_2] Set value of OUT2 500 L/min [H_2] Hysteresis of OUT2 50 L/min PF2MC7202 Item Default settings [P_1] Set value of
/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9 D-M9V D-F9W D-F9WV D-F9BAL D-Y59A/Y7P/Y59B
Bore size mm (in) Bore size Operating range Operating range l (mm) 180 200 15 (0.6) 15 (0.6) 9 Series CQ2 Compact Cylinder Solid State Auto Switches/Direct Mounting Type D-Y59 , D-Y69 , D-Y7P (V) A B A B Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y7PV D-Y59B D-Y59A D-Y69A D-Y7P D-Y69B Auto switch model no.
A r-ll B T-l I t# r. r-1 zK 9K Flg. 8.25 Two cylinder cascade- P N E U M A T I C T E C H N O L O G Y APPENDIX SYMBOLS T H E S Y M B O L S F O R F L U I D P O W E R S Y S T E M S A N D C O M P O N E N T S A R E S T A N D A B D T Z E D I N I S O 1 2 1 9 . T H E S T A N D A R D C O M B T N E S H Y D R A U L I C A N D P N E U M A T I C C O M P O N E N T S .
A r-ll B T-l I t# r. r-1 zK 9K Flg. 8.25 Two cylinder cascade- P N E U M A T I C T E C H N O L O G Y APPENDIX SYMBOLS T H E S Y M B O L S F O R F L U I D P O W E R S Y S T E M S A N D C O M P O N E N T S A R E S T A N D A B D T Z E D I N I S O 1 2 1 9 . T H E S T A N D A R D C O M B T N E S H Y D R A U L I C A N D P N E U M A T I C C O M P O N E N T S .
Bore size (mm) Applicable switch Note 175 200 250 300 400 500 150 125 100 75 25 50 12 Switch mounting screw (M3 x 0.5 x 8l) Square nut D-A7, A8 D-A7H, A80H D-A73C, A80C D-A79W D-F7V D-F7, J7 D-J79C D-F7WV D-F79W, J79W 12 20 BQ-1 20 32 32 40 50 63 40 Switch mounting screw (M3 x 0.5 x 10l) Switch spacer Switch mounting nut 50 BQ-2 63 Contact SMC regarding non-standard strokes.
Auto Switch Proper Mounting Position (mm) Auto switch model D-M9 D-M9W D-A9 Bore size A A B B 20 25 32 40 10.5 9.5 6.5 5.5 10.5 9.5 6.5 5.5 11.5 10.5 7.5 6.5 17.5 15.5 13.5 11.5 Note) The above-mentioned value is a guide for auto switch mounting positions for stroke end detection.
Auto Switch Proper Mounting Position (at Stroke End Detection) Center of magnet A D-M9m, D-M9mV D-M9mW, D-M9mWV (mm) D-A9, D-A9mV (mm) A Operating range Bore size 16 25 A Operating range Bore size 16 25 30 9 34 4.5 30 9 34 4.5 Note) Only adjust the setting position after confirming the auto switch is properly activated.
ON/OFF / / 2 3 3 2 1 2 / -20- 3.3. [] LEC LEC / P.32 5.3 <> NPNPNP LEFS16A-100 NPN <> INPIN []INP ON ON INP ON OFF -21- <> No.1 01 a b c d e f g h i j k a ABSINC No. 1 2 mm/s mm mm/s2 mm/s2 % % mm/s % mm mm mm 0 ABS 250 50.00 3000 3000 0 0 0 100 48.00 50.00 0.50 1 ABS 250 0.00 3000 3000 0 0 0 100 0.00 2.00 0.50 ABS()/ / INC()// b c d e f 00 g h i 100%DC24V 250% j 12
Model Series VEA amplifiers are exclusively used for driving electropneumatic proportional valves, and have 3 important tunctions. vEA 250/130 Basic type having driving function only vEA 251 As a system safety measure, an abnormality detecting circuit is added to vEA 250. l.Command Signal A low power DC voltage controls the output current.
(max. 20 stations) 3 SY3000 5 SY5000 Connector mounting position A, B port size Symbol Mounting position U U side SY5000 SY3000 D D side Symbol Port size 4 One-touch fitting C4 Symbol Port size 4 One-touch fitting C4 6 One-touch fitting C6 Mixed M 6 One-touch fitting C6 Valve stations 8 One-touch fitting C8 Mixed M Stations Symbol Note Single wiring specifications (up to 16 solenoids are