(Recommended height 5 mm) Dimensions [mm] Stroke L A B n D E 150 389 156 328 4 150 200 439 206 378 6 2 300 250 489 256 428 6 2 300 300 539 306 478 6 2 300 350 589 356 528 8 3 450 400 639 406 578 8 3 450 450 689 456 628 8 3 450 500 739 506 678 10 4 600 550 789 556 728 10 4 600 600 839 606 778 10 4 600 650 889 656 828 12 5 750 700 939 706 878 12 5 750 750 989 756 928 12 5 750 800 1039 806
T4 = 0.05 [s] T1 = V/a1 = 300/5000 = 0.06 [s], T3 = V/a2 = 300/5000 = 0.06 [s] T2 = = = 0.94 [s] L 0.5 V (T1 + T3) V 300 0.5 300 (0.06 + 0.06) 300 T4 = 0.05 [s] Therefore, the cycle time can be obtained as follows.
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 605, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 730, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 605, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 730, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
15 8.5 1/8 (P, R port) 32 24 45.5 L plug connector (L): 10-SYJ5 43-L-01 3 4 5 M plug connector (M): 10-SYJ5 43-M-01 3 4 5 DIN Terminal (D): 10-SYJ5 43-D-01 3 4 5 M8 connector (WO): 10-SYJ5 43-WO-01 3 4 5 Applicable cable O.D. 3.5 to 7 Approx. 300 (Lead wire length) 82.9 MAX.10 75.4 50.1[57.1] 64.1 34.7 49 M8 x 1 54.6 37.1 61.2[68.2] Approx. 300 (Lead wire length) 6 Pg7 6 6 6 65.8 59.3 103.4
/J79 D-J79C D-F7V D-F7NTL D-F7W/J79W D-F7WV D-F7BAL D-A7/A80 D-A7H/A80H D-A73C/A80C D-F7LF D-F79F Bore size (mm) B A 10 6 3 4.5 (mm) 15 6 4 4.5 Dimension A Dimension B 20 6 3 4.5 Auto switch model D-A72 D-A72 25 6 3 4.5 D-F7W/J79W D-F7WV D-F7LF Note 1) D-F7W/J79W D-F7WV D-F7LF Note 1) D-F79F D-F7BAL D-A7H/A80H D-A73C/A80C D-F7/J79 D-J79C D-F7V D-A7H/A80H D-A73C/A80C D-F7/J79 D-J79C D-F7V
Mounting: A (Both Ends Tapped), Bore Size: 32mm, Thread: TN (NPT Thread), Full Stroke: 300mm, First Stroke: 245mm, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)
Bearing Style: Ball Bush Bearing, Bore Size: 63mm, Port Type: -, Stroke: 300mm, Locking Direction: Retraction Stroke Lock, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -
Bearing Style: Ball Bush Bearing, Bore Size: 63mm, Port Type: -, Stroke: 300mm, Locking Direction: Extension Stroke Lock, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -
Mounting: Both Ends Tapped, Bore Size: 32mm, Thread: NPT Thread, Full Stroke: 300mm, First Stroke: 245mm, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -
276 17 310.5 300 286.5 12 323 312.5 297 13 SS5Y3-45FU-D .
Reed auto switch: D-A9, D-A9V Solid state auto switch: D-M9(A), D-M9W D-M9 Compact auto switch D-A9 5 Air Slide Table MXQ Series Functional Options ' With buffer mechanism Protects workpieces and tools by eliminating impact at the extension stroke end Buffer unit is auto switch capable.
Positioning distance (mm) 600 300 100 10 1 10 60.5 30.5 10.5 1.5 0.5 100 6.5 3.5 1.5 0.6 0.5 Speed (mm/s) 150 4.5 2.5 1.2 0.6 0.5 300 2.6 1.6 0.9 0.6 0.5 Values will vary slightly depending on the operating conditions.
Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y59A, D-Y69A D-Y59A D-Y69A D-Y7P D-Y7PV D-Y59B D-Y69B Auto switch model no.
MB1 D-G5/K5/G5W/G5BA D-K59W, D-G59F, D-G5NT 20 to 100 D-C7/C8, D-C73C/C80C 20 to 63 CA2 CS1 Hs Hs CS2 24.5 16 A B B A D-B5/B6/B59W 20 to 100 D-H7/H7W D-H7NF/H7BA/D-H7C 20 to 63 Hs Hs 24.5 16 B A A B Auto Switch Mounting Height (mm) D-H7 D-H7W D-H7NF D-H7BA D-C7/C8 Auto switch model D-G5/K5 D-G5W D-K59W D-B5/B6 D-B59W D-M9(V) D-M9W(V) D-M9A(V) D-A9(V) D-G5NT D-G59F D-H7C D-G5BA D-C73C D-C80C
(mm) Auto Switch Mounting Height D-A9l(V) D-M9l(V) D-M9lW(V) D-M9lA(V) D-H7l D-H7lW D-H7BA D-H7NF D-C7l D-C80 Auto switch model D-B5l D-B64 D-B59W D-G5NT D-H7C D-G39A D-K39A D-A3lA D-A44A D-C73C D-C80C Hs Hs Hs Hs Hs 20 24.5 25.5 25 60 69.5 25 27 28 27.5 62.5 72 32 30.5 31.5 31 66 75.5 40 34.5 35.5 35 70 79.5 Bore size D-X Technical Data 263 CM2 Series Auto Switch Proper Mounting Position