Magnet: Built-in, Mounting: Front Flange, Type: Standard, Bore Size: 25mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector:
Magnet: Built-in, Mounting: Front Flange, Type: Standard, Bore Size: 25mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: Double Knuckle Joint, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Mounting Threads: -, Rod Type: -, Speed
Magnet: Built-in Magnet, Mounting: Rod Flange, Type: Pneumatic, Bore Size: 25mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke 1: 10mm, +: None, Stroke 2: None, Body Option: with Rubber Bumper, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: No Switch, Lead Wire or Prewired Connector: 1m, Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options:
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 10, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in
Magnet: D (Built-in), Mounting: F (Front Flange), Type: Standard, Bore Size: 25mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9N--Solid State , Gen.
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Type: Pneumatic, Bore Size: 25mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke 1: 40mm, +: None, Stroke 2: None, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector
Magnet: D (Built-in), Mounting: F (Front Flange), Type: Standard, Bore Size: 25mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: W (Double Knuckle Joint), Auto Switch: M9N--Solid State , Gen.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Magnet: Built-in, Mounting: Front Flange, Type: Standard, Bore Size: 25mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: None, Rod End Bracket: Double Knuckle Joint, Auto Switch: M9N--Solid State , Gen.
CK1 Load voltage Auto switch model Lead wire length (m) Pre-wired connector Applicable load DC AC Band mounting Rail mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line Perpendicular In-line Indicator light Type Special function Electrical entry Wiring (Output) C(L)K M9NV M9N M9NV M9N V V V v v IC circuit 3-wire (NPN) C(L)KU 5 V,12 V 3-wire (PNP) M9PV M9P M9PV M9P V V V v
How to Order [Option] XLGV M9N 16 A 1 G L Flange size 16, 25, 40 1 q e u r t XLGV M9N 50 A 1 G L Flange size 50, 63, 80 i w y o !0 !
How to Order MHZ Bore size MHF MHS 3 D 20 16 to 25 M9N MHL Number of auto switches MHR Nil S 2 pcs. 1 pc.
Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.
Data
D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch part no.
SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.? Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving?ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125,?
SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.? Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving?ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125,?
SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.? Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving?ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125,?