Suitable for static neutralization at a long distance (max. 500 mm).
3/8 9.2 2.4 2.0 2.4 JSXD31-C Sm03 500 1/2 9.2 2.4 2.0 2.4 JSXD31-C Sm04 500 Brass Stainless steel 0.02 1.0 Table of UL-compliant Products JSXD Series JSXZ Series JSXM Series Option Replacement Parts 40 Brass Stainless steel 3/8 15 18 0.35 5.0 3.9 4.5 JSXD41-C Sm03 720 1/2 20 5.5 4.6 5.5 JSXD41-C Sm04 720 50 Brass/Stainless steel 3/4 20 38 0.30 9.5 8.2 9.5 JSXD51-C Sm06 880 60 Brass/Stainless
Operating speed Make sure to connect a speed controller to the cylinder and adjust its speed to 500 mm/s or less. If a load is to be attached to the end of the rod, adjust the speed to the maximum speed shown in Graph (1) or less, in accordance with the added mass.
Maximum piston speed: 500 mm/s It can be used at 50 to 500 mm/s provided that it is within the allowable kinetic energy range.
600 700 800 900 1000 1200 245.7 345.7 445.7 545.7 645.7 745.7 845.7 945.7 1045.7 1145.7 1345.7 400 500 600 700 800 900 1000 1100 1200 1300 1500 50 150 250 350 450 550 650 750 850 1050 70 170 270 370 470 570 670 770 870 1070 Note) Dimensions inside ( ) are for a 100mm stroke. 4 Series LG1H High Rigidity Direct Acting Guide Type LG1H20: Without Coupling / Construction 9 5 bn bn 4 8 1 3 2
25 EJ302S-025X11 50 EJ302S-050X11 75 EJ302S-075X11 1 EJ402S-001X11 3 EJ402S-003X11 5 EJ402S-005X11 10 EJ402S-010X11 65 x 500 25 EJ402S-025X11 50 EJ402S-050X11 75 EJ402S-075X11 Note) Seals are not necessary.
25 EJ302S-025X11 50 EJ302S-050X11 75 EJ302S-075X11 1 EJ402S-001X11 3 EJ402S-003X11 5 EJ402S-005X11 10 EJ402S-010X11 65 x 500 25 EJ402S-025X11 50 EJ402S-050X11 75 EJ402S-075X11 Note) Seals are not necessary.
0.5 to 25 L/min 1 to 50 L/min 2 to 100 L/min 1 to 10 L/min 50 to 500 L/min 5 to 500 L/min 10 to 1000 L/min 20 to 2000 L/min 0 to 0.5 L/min 0 to 1 L/min 0 to 3 L/min 0.5 to 0.5 L/min 1 to 1 L/min 3 to 3 L/min 5 to 500 L/min 2 to 200 L/min 5 to 50 L/min 150 to 3000 L/min 10 to 1000 L/min 10 to 100 L/min 300 to 6000 L/min 20 to 2000 L/min 20 to 200 L/min 600 to 12000 L/min 24 VDC 10% 12 to
Standard stroke Nominal size Standard stroke (mm) Max. manufacturable stroke (mm) 16, 25 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1000 Strokes are manufacturable in increments of 1 mm, up to the maximum stroke. However, when a stroke out of the standard 51 to 599 is required, add "-XB10" at the end of the model no.
1000 1500 Piston speed mm/s 100 200 300 400 500 1000 1500 Piston speed mm/s 100 200 300 400 500 1000 1500 Piston speed mm/s MY2C MY2 H/HT Maximum Load Mass Select the load mass from within the range of limits shown in the graphs.
IS 0 1 MPa PSE560 100 kPa (0.1 MPa) 1 MPa ZSM For positive pressure 0 500 kPa PF2 PSE564 50 kPa 500 kPa IF Rated pressure range of sensor Regulating pressure range of controller Data 16-3-31
m(kg) Load weight: m(kg) 160 600 600 140 500 500 125 400 400 300 300 200 200 100 100 100 500 400 300 200 100 500 400 300 200 Maximum speed: V(mm/s) Maximum speed: V(mm/s) 31
200 100 100 500 400 300 200 100 Maximum speed: V(mm/s) Maximum speed: V(mm/s) Graph 6 Graph 3 0.4MPaP<0.5MPa 0.4MPaP<0.5MPa 3000 3000 2000 2000 160 140 1000 1000 700 800 900 700 800 900 125 Load weight: m(kg) Load weight: m(kg) 600 600 160 500 500 400 400 140 320 125 300 300 200 200 280 100 100 100 500 400 300 200 100 500 400 300 200 Maximum speed: V(mm/s) Maximum speed: V(mm/s) Graph 7
400 300 500 400 300 L-unit Air cushion 200 200 Caution 1002 3 4 5 10 20 50 100 1 2 3 4 5 10 20 30 400 50 1.
switch Reed switch Type Model Action Series Built-in auto switch magnet With rod boot Spring lock Grommet Grommet Mounting 3 wire 3 wire 2 wire D-F59 D-F59W D-J59W D-F5P D-F5PW D-F5BAL (2 color indicator) (2 color indicator) 2 wire 4 wire 3 wire D-J59 D-F59F D-F5NTL D-F5LF (2 color indicator) D-A53 D-A54 D-A56 D-A64 D-A67 D-A59W (2 color indicator) Single rod Series MNB 40 50 63 80 100 25 to 500
speed (mm/s) Collision speed (mm/s) L unit 1000 1000 Air cushion 500 400 300 500 400 300 L unit Air cushion 200 200 1002 3 4 5 10 20 50 100 1 2 3 4 5 10 20 30 400 50 Caution Load weight (kg) Load weight (kg) 1.
Rubber Seal 3 Port Solenoid Valve Series 10-SYJ300/500/700 Directional Control Valves Air Grippers Modular F. R.
*1: To use the power of the device, the total load current must be 500 mA or less.
empty weight deflection 2 2 Lateral empty weight deflection Lateral empty weight deflection 1 1 0.5 0.5 0.2 0.2 0.1 0.1 200 300 500 1000 100 Load point distance mm 200 300 500 1000 100 Load point distance mm 146
Wall mounting Cylinder MY1MW40-500 z Average operating speed a 200 mm/s Mounting orientation Horizontal mounting y Wd: Workpiece (500 g) x y Wc: MHL2-16D1(795 g) x z Wa: Connection plate t = 10 (880 g) x 3. Ceiling mounting 4. Vertical mounting MY1MW40-500 z y x y z Wb: MGGLB25-200 (4.35 kg) For actual examples of calculation for each orientation, refer to the pages above. 2.