The speed will be approximately 1.4 times the date given on p.4.12-3.
number. *2: Select a protocol before performing pairing (V.2.0: 1 Mbps, V.1.0: 250 kbps).
Applicable strokes: 250, 350, 450, 550, 650, 700, 750, 850, 900, 950, 1050, 1100, 1150, 1250, 1300, 1350, 1400, 1450 Example) LJ1H3031PD-250-F2-X2 Allowable Moment (Nm) Allowable static moment Allowable dynamic moment Pitching Rolling Yawing Mounting orientation Load movement direction 117 137 123 Model LJ1H30 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep a = 1000 2000 L1
(port e)] [P (port c)] A A LW Plug Operating direction P (port a) P (port b) Auto switch mounting groove [P (port g)] 0.5 Note 2) 0.5 Note 2) Left Right Plug [P (port h)] HI HP H HL HG HT HS HB HA HB HA HG HT HI WB 4-J Depth JK Plug [P (port f)] WB WA TA TA WA R TB Plug TB R W [P (port d)] Inner cover Note 3) holding screw (mm) K 21 20 JK 10 12 J M6 x 1 M10 x 1.5 HT 19.5 39 HS 27 49.5 HP
Applicable bore A 0.51 D C 1/4-28 UNF B 0.16 JM-025 0.44 3/4", 7/8" JM-03 0.50 0.19 5/16-24 UNF 0.50 1 1/16" JM-045 0.69 0.79 0.26 7/16-20 UNF 1 1/4", 1 1/2" JM-04 0.56 3/8-24 UNF 0.65 0.23 1 1/4", 1 1/2" (Non-rotating) JM-05 0.75 1/2-20 UNF 0.32 0.87 2" 6-14-20 21 Series NCM Mounting Bracket Accessory Material: Rolled steel P dia.
Magnet With auto switch only 9 Magnet plate Stainless steel With auto switch only 10 Scraper 11 Rod seal 12 Piston seal NBR 13 Tube gasket 14 Piston gasket 269 CHKD Series Dimensions Basic type/CHKDB 2 x Rc P F with effective thread depth G F with effective thread depth G Q Q Width across flats f c R D R a b g e H E E h + Stroke C B + Stroke 4 x K through 8 x L counter bore 4 x K through
BM51 BM52 BM53 BM54 BM55 BM56 BM57 How to Order AME 250 03 R B Option R INOUT reversal Body size HAl Accessories (Options) 150 250 350 450 550 650 850 1/8 1/4 3/8 1/2 3/4 None B AT With bracket IDl Port size 1/8B 01 02 03 04 06 10 14 20 2B 1 Thread 1/4B AMG 11/2 3/8B Rc(PT) F G(PF) N NPT 1/2B AFF 3/4B 1B AMl 11/2B Symbol Related poroducts AME Note) Refer to p.4.7-7 for "How to Order" case
Vertical actuation I II P W A P a (b) (a) P P a A W (1) Basically adjusted with meter-out control. When meter-in control is also used, lurching is reduced. (1) Basically adjusted with meter-out control.
For critical applications use A at 2 PSI P . A 10 PSI P will save money and mounting space. Method 2: Chart Index Cv against Bore Size vs. Inches of stroke per second. Assuming 80 PSI and P = 80%.
For critical applications use A at 2 PSI P . A 10 PSI P will save money and mounting space. Method 2: Chart Index Cv against Bore Size vs. Inches of stroke per second. Assuming 80 PSI and P = 80%.
/300-A-20. 8-1 8.1.2 HRSH100/150/200/250/300-A-40. 8-2 8.1.3 HRSH100/150/200/250-W-20. 8-3 HRSH Series HRX-OM-Q026 Contents 8.1.4 HRSH100/150/200/250-W-40. 8-4 8.1.5 Option T High head temp . 8-5 8.1.6 Refrigerant with GWP reference . 8-6 8.1.7 Communication specifications . 8-6 8.2 Dimensions . 8-7 8.2.1 HRSH100-A-20/40. 8-7 8.2.2 HRSH150-A-20/40-, HRSH200-A-20/40. 8-8 8.2.3 HRSH250/300-
Please refer to p.4.4-2 for flow rate and to p.4.4-3 for graph of max. flow. Specifications Compressed air 1.0MP Fluid Max. operating pressure Through the adoption of an element that is used exclusively for removing water drops and the provision of ample housing interior space, a 99% water removal rate has been achieved.
Pilot port * Details of the mounting bolts P. 6 Stroke/Minimum stroke for auto switch mountings P. 15 Bore size Standard stroke [mm] 5 10 15 20 25 30 35 40 45 50 12 16 20 25 Applicable Auto Switches/Refer to the Web Catalog or Best Pneumatics for further information on auto switches.
The amount of air requirement of rotary actuator = 0.06 x V x (P/0.1)/t l/min(ANR) V : Inner volume = cm3 P : Absolute pressure = {Operating pressure (MPa) + 0.1} t : Operating time = s CRB2 CRBU2 CRB1 Calculate the required air volume separately for the linear motion part and the rotary motion part.
F T n t kg RS H A Me 2 2 2 E 2 2 E 2 2 E 2 2 E 2 E m = 20 kg = 0.7 m/s d = 40 mm p = 0.5 MPa n = 20 cycle/min t = 25C rad/s 2.
Note 2) The seal is for 40 m and 80 m elements. 784 Vacuum Filter AFJ20 to AFJ40 Series Dimensions AFJ20 N T J M D U Bracket (Option) S SP R ZCUK C B V Q IN OUT AMJ AFJ AFJ 2 x P (Port size) AMV ZH -X185 Related Products Clearance for maintenance G A AFJ30, AFJ40 N T J D M U Bracket (Option) S R C V Q IN OUT 2 x P (Port size) B Clearance for maintenance G A E Model Standard specifications
Description Material AS800 AS900 y u i JIS B 2401 P-7 JIS B 2401 P-7 AQ NBR O-ring u O-ring O-ring Spring NBR NBR Stainless steel JIS B 2401 P-12 JIS B 2401 G-50 14115 JIS B 2401 P-16 JIS B 2401 G-65 14124 JIS B 2401 P-48 JIS B 2401 P-38 NBR O-ring ASV i AK ASS Dimensions: AS420/500/600 Dimensions: AS800/900 ASR ASF 2-Port size 2-Port size Dimensions Dimensions L1 L2 L4 Min.
Contact P/A regarding the bowl assembly supply for PSI and F unit specifications.
1209, 1210 P. 1204 to 1206 P. 1204 to 1206 P. 1207, 1208 P. 1211, 1212 Buffer stroke Pad dia. 40 50 63 80 100 125 Buffer stroke (mm) 25 50 75 100 Pad Material and Characteristics Characteristics Base resistance Acid resistance Weatherability Ozone resistance Abrasion resistance Waterproof Solvent resistance (Benzene, toluene) Oil resistance benzol Oil resistance gasoline Operating temperature
mm Displayable/Settable range (Distance reference) *1 0 to 60 *4 10 to 300 *4 30 to 500 *4 Minimum display unit (Distance reference) *1 1 Rated pressure range 100 to 200 kPa Displayable range (Pressure value) *2 20 to 220 kPa Withstand pressure 600 kPa Detection nozzle 1.5 *3 Consumption flow rate 5 L/min or less 12 L/min or less 22 L/min or less Power supply voltage 24 VDC 10%, Ripple (p-p