SMC Corporation of America
Elite Part Number Search
Search Results "CLA2B100TN-250-P"

Accessories (Options) Applicable model Bracket assembly AMF150 AMF250 AMF350 AMF450 AMF550 AMF650 AMF850 Symbol BM51 BM52 BM53 BM54 BM55 BM56 BM57 spring washer With cap bolt, AMF Refer to ''Precautions" on p.4.6-33. 4.6-27 Odor Removal Filter Series AMF AMF150 to AMF850 How to Order AMF 250 03 R B Option R IN, OUT reversal Body size Accessories (Optional) 150 1 8 250 1 4 350 3 8 450 1 2

Ambient and fluid temperature Piston speed Cushion Thread tolerance JIS class 2 +0.8 0 +1.0 0 +1.25 0 +1.4 0 +1.8 0 to 100mm mm, 100 to 250mm mm, 250 to 630mm mm 630 to 1000mm mm, 1000 to 1200mm mm Stroke length tolerance Basic type (B), Axial foot type (L), Front flange type (F), Rear flange type (G), Single clevis type (C), Double clevis type (D), Center trunnion type (T), Front trunnion

Port A Port P Pilot Pressure Port P (N.O.) Model Pressure (MPa) 0.25 to 0.7 VXA31 4 VXA32 4 Option Material No.

Possible to install auto switches Series Variations Standard stroke (mm) Rod end configuration Applicable auto switch Action Type Bore size (mm) 5 10 15 20 25 30 35 40 45 50 75 100 125 150 175 200 250 300 25 Single rod 32 Reed switch D-A7 D-A8 (2-color) D-A79W Double acting 40 50 Double rod Male thread, Female thread 63 Solid state switch D-A7 D-J79 (2-color) D-F7W D-J79W 25 32 Spring return

Faster Average speed [mm/s] Measuring conditions Supply pressure: 0.55 MPa 0 50 100 150 125-250 160-300 Bore size-Stroke 200-300 250-450 320-530 Speed adjustment rotary switch set value 0 5 9 Mounting: Vertical downward Load: no-load Operating direction: Upward *1 The average speed value is the stroke divided by the full stroke time.

Possible to install auto switches Series Variations Standard stroke (mm) Rod end configuration Applicable auto switch Action Type Bore size (mm) 5 10 15 20 25 30 35 40 45 50 75 100 125 150 175 200 250 300 25 Single rod 32 Reed switch D-A7 D-A8 (2-color) D-A79W Double acting 40 50 Double rod Male thread, Female thread 63 Solid state switch D-A7 D-J79 (2-color) D-F7W D-J79W 25 32 Spring return

The speed will be approximately 1.4 times the date given on p.4.12-3.

number. *2: Select a protocol before performing pairing (V.2.0: 1 Mbps, V.1.0: 250 kbps).

Applicable strokes: 250, 350, 450, 550, 650, 700, 750, 850, 900, 950, 1050, 1100, 1150, 1250, 1300, 1350, 1400, 1450 Example) LJ1H3031PD-250-F2-X2 Allowable Moment (Nm) Allowable static moment Allowable dynamic moment Pitching Rolling Yawing Mounting orientation Load movement direction 117 137 123 Model LJ1H30 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep a = 1000 2000 L1

(port e)] [P (port c)] A A LW Plug Operating direction P (port a) P (port b) Auto switch mounting groove [P (port g)] 0.5 Note 2) 0.5 Note 2) Left Right Plug [P (port h)] HI HP H HL HG HT HS HB HA HB HA HG HT HI WB 4-J Depth JK Plug [P (port f)] WB WA TA TA WA R TB Plug TB R W [P (port d)] Inner cover Note 3) holding screw (mm) K 21 20 JK 10 12 J M6 x 1 M10 x 1.5 HT 19.5 39 HS 27 49.5 HP

Applicable bore A 0.51 D C 1/4-28 UNF B 0.16 JM-025 0.44 3/4", 7/8" JM-03 0.50 0.19 5/16-24 UNF 0.50 1 1/16" JM-045 0.69 0.79 0.26 7/16-20 UNF 1 1/4", 1 1/2" JM-04 0.56 3/8-24 UNF 0.65 0.23 1 1/4", 1 1/2" (Non-rotating) JM-05 0.75 1/2-20 UNF 0.32 0.87 2" 6-14-20 21 Series NCM Mounting Bracket Accessory Material: Rolled steel P dia.

Magnet With auto switch only 9 Magnet plate Stainless steel With auto switch only 10 Scraper 11 Rod seal 12 Piston seal NBR 13 Tube gasket 14 Piston gasket 269 CHKD Series Dimensions Basic type/CHKDB 2 x Rc P F with effective thread depth G F with effective thread depth G Q Q Width across flats f c R D R a b g e H E E h + Stroke C B + Stroke 4 x K through 8 x L counter bore 4 x K through

BM51 BM52 BM53 BM54 BM55 BM56 BM57 How to Order AME 250 03 R B Option R INOUT reversal Body size HAl Accessories (Options) 150 250 350 450 550 650 850 1/8 1/4 3/8 1/2 3/4 None B AT With bracket IDl Port size 1/8B 01 02 03 04 06 10 14 20 2B 1 Thread 1/4B AMG 11/2 3/8B Rc(PT) F G(PF) N NPT 1/2B AFF 3/4B 1B AMl 11/2B Symbol Related poroducts AME Note) Refer to p.4.7-7 for "How to Order" case

Vertical actuation I II P W A P a (b) (a) P P a A W (1) Basically adjusted with meter-out control. When meter-in control is also used, lurching is reduced. (1) Basically adjusted with meter-out control.

For critical applications use A at 2 PSI P . A 10 PSI P will save money and mounting space. Method 2: Chart Index Cv against Bore Size vs. Inches of stroke per second. Assuming 80 PSI and P = 80%.

For critical applications use A at 2 PSI P . A 10 PSI P will save money and mounting space. Method 2: Chart Index Cv against Bore Size vs. Inches of stroke per second. Assuming 80 PSI and P = 80%.

/300-A-20. 8-1 8.1.2 HRSH100/150/200/250/300-A-40. 8-2 8.1.3 HRSH100/150/200/250-W-20. 8-3 HRSH Series HRX-OM-Q026 Contents 8.1.4 HRSH100/150/200/250-W-40. 8-4 8.1.5 Option T High head temp . 8-5 8.1.6 Refrigerant with GWP reference . 8-6 8.1.7 Communication specifications . 8-6 8.2 Dimensions . 8-7 8.2.1 HRSH100-A-20/40. 8-7 8.2.2 HRSH150-A-20/40-, HRSH200-A-20/40. 8-8 8.2.3 HRSH250/300-

Please refer to p.4.4-2 for flow rate and to p.4.4-3 for graph of max. flow. Specifications Compressed air 1.0MP Fluid Max. operating pressure Through the adoption of an element that is used exclusively for removing water drops and the provision of ample housing interior space, a 99% water removal rate has been achieved.

Pilot port * Details of the mounting bolts P. 6 Stroke/Minimum stroke for auto switch mountings P. 15 Bore size Standard stroke [mm] 5 10 15 20 25 30 35 40 45 50 12 16 20 25 Applicable Auto Switches/Refer to the Web Catalog or Best Pneumatics for further information on auto switches.

The amount of air requirement of rotary actuator = 0.06 x V x (P/0.1)/t l/min(ANR) V : Inner volume = cm3 P : Absolute pressure = {Operating pressure (MPa) + 0.1} t : Operating time = s CRB2 CRBU2 CRB1 Calculate the required air volume separately for the linear motion part and the rotary motion part.