R V Basic type (B)/CG5BAS : With air cushion WA WB GA GB 2-P W 10 H1 Width across flats B1 M BM Max.
Cylinder Bore Sizes (in inches) Valve Type Cv Type* 34 1 118 112 2 214 212 3 314 4 6 Micro-Line 0.11 SA F S S LTV 0.18 SA,DA F F F F M M M M S S Nova 1.00 SA,DA F F F F F F F M M Duramatic 0.18 SA,DA F F F F M M M M S S Duramatic 0.63 SA,DA F F F F F M M M M Capsula 0.75 SA,DA F F F F F F M M M Capsula 3.17 SA,DA F F F FT-1, FC-1 0.13 SA F F M S 4B-1, 4W-1 0.48 SA,DA F F F F M M M S FC51,
Cylinder Bore Sizes (in inches) Valve Type Cv Type* 34 1 118 112 2 214 212 3 314 4 6 Micro-Line 0.11 SA F S S LTV 0.18 SA,DA F F F F M M M M S S Nova 1.00 SA,DA F F F F F F F M M Duramatic 0.18 SA,DA F F F F M M M M S S Duramatic 0.63 SA,DA F F F F F M M M M Capsula 0.75 SA,DA F F F F F F M M M Capsula 3.17 SA,DA F F F FT-1, FC-1 0.13 SA F F M S 4B-1, 4W-1 0.48 SA,DA F F F F M M M S FC51,
[oC] correction coefficient Less than 1000m 45 1.00 1000 m or more Less than 1500 m 42 0.85 1500m or more Less than 2000m 38 0.80 2000m or more Less than 2500m 35 0.75 2500m or more Less than 3000m 32 0.70 Installation/Operation in an ambient temperature of 10 oC or less Use ethylene glycol solution at a concentration of 15 % for the circulating fluid.
0 n r Ro 18 tio ta or tio ta t f n r Ro fla an le ge ng of si +10 0 0 Ro 19 tat or io t f n r fla an gle ge sin of With external stopper For 90 For 180 Single flat Single flat 5 A A e ng ng ng le le ra ad ad t ju ju en st st m m m st en en ju t r t r ad an an gle ge ge An 5 5 B port A port B port A port 90 A 5 ng ge le an ad t r ju en st m 180 Note) The drawings show the rotation range
M5 x 0.8 (P, R1, R2 port) 17.5 14 28 L plug connector (L): 10-SYJ3 43-L-M5 M plug connector (M): 10-SYJ3 43-M-M5 M8 Connector (WO): 10-SYJ3 43-WO-M5 3 4 5 3 4 5 3 4 5 Approx. 300 (Lead wire length) 41.5[48.5] 26.1 46 M8 x 1 28.5 52.6[59.6] Approx. 300 (Lead wire length) 55.8 32.6 49.3 111.5[115.9] R1 P R2 R1 P R2 R1 P R2 91.9[96.3] 10 10 10 10 10 10 28 28 28 109.7 14 14 14 5 5 5 37.6[39.8
physical property values by circulating uid. m x C x (Tt T0) x V x C x T Q = = t t 1 x 150 x 4.186 x 103 x 10 900 = = 6977 [J/s] 7.0 [kW] m x C x (Tt T0) t x 860 x V x 60 x C x T t x 860 Q = = Cooling capacity = Considering a safety factor of 20%, 7.0 [kW] x 1.2 = 1 x 150 x 60 x 1.0 x 103 x 10 15 x 860 8.4 [kW] = Q x t: Heat capacity [kJ] Thermo-chiller 6977 [W] = 7.0 [kW] Water bath
heat radiation efficiencies of the devices in the product will be lower in the location at an altitude of 1000 m or higher.
Model Description AC10 AC20 AC25 AC30 AC40 AC40-06 AC50 AC55 AC60 G-27-10-R1 G36-10-01 GC3-10AS G36-2-01 GC3-2AS AD27 G36-10-01 GC3-10AS G36-2-01 GC3-2AS AD38 AD37 G36-10-01 GC3-10AS G36-2-01 GC3-2AS AD38 AD37 G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48 AD47 G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48 AD47 G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48 AD47 G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48
100 6-5-52 53 Series CG1Q Air Cylinder: Low Friction Type Double Acting, Single Rod With Mounting Bracket Without rod boot ZZ Axial Foot Style Axial foot style: CG1LQ Without rod boot Z Bore (mm) B LC LD LH LS LT LX LZ M W X Y 20 25 32 40 50 63 80 100 34 4 4 4 4 5 5 6 6 6 6 7 7 10 12 11 14 20 53 53 53 60 67 67 74 74 3 10 10 10 10 17.5 17.5 20 20 15 7 3 3 3 3 4.5 4.5 4.5 6 32 44 47 52 53
HRS012/018--10-T/MT HRS012/018/024/030--20-T HRS012/018/024/030--20-MTNote 1) Applicable model Rated flow50/60Hz Note 2) 3) 7(0.36MPa)/10(0.42MPa) 10(0.44MPa)/14(0.40MPa) 10(0.32MPa/)/14(0.32MPa) Pump 18/22 Maximum flow rate (50/60 Hz) L/min Maximum pump head (50/60 Hz) m 55 70 60 Output W 320 550 Circuit protector 15A (10 A for standard) A 15 Recommended earth leakage breaker capacity 15
Facility water temperature 32C 12 Cooling capacity [kW] 10 8 Facility water temperature 40C 6 4 2 0 5 10 15 20 25 30 35 40 Circulating fluid temperature [C] Pump Capacity HRSH090--20/400.6 60 Circulating fluid pressure [MPa] 0.5 50 Outlet Pump head [m] 0.4 40 0.3 Usable flow rate range 30 0.2 20 Return port 0.1 10 0 0 20 10 40 30 50 60 70 Circulating fluid flow rate [L/min] 0 140 Thermo-chiller
M Weight (g) AS221F-U01-23 AS221F-U01-04 AS221F-U01-06 AS221F-U01-08 AS221F-U01-10 AS221F-U02-04 AS221F-U02-06 AS221F-U02-08 AS221F-U02-10 AS321F-U02-06 AS321F-U02-08 AS321F-U02-10 AS321F-U02-12 AS321F-U03-06 AS321F-U03-08 AS321F-U03-10 AS321F-U03-12 AS421F-U04-10 AS421F-U04-12 Model Applicable tubing O.D. d 3.2 4 6 8 10 4 6 8 10 6 8 10 12 6 8 10 12 10 12 27.9 28.2 29.6 32.4 40.2 32.5 33.1
M1 3A = M1E/M1E max = 2.25/10 = 0.225 m x g L1 M1E FE M3E = 0.05 x a x m x L2 (FE = 1.4/100 x a x g x m) = 0.05 x 300 x 3 x 0.04 = 1.8 [Nm] Investigate M3E. a From above, find the value of M3E max at 420 mm/s in Graph (3).
An error code is returned if an instruction code outside the range set in parameter No.
9.4 Cooling capacity 9-7 HRX-OM-W038 Chapter 9 Documents 9.6 Pump capacity 9.6.1 HRS040--20-(BJMWZ) 0.3 0.3 30 Availavel area (Min. neccesary flow5L/min) Circulating fluid pressure[MPa] Availavel area (Min. neccesary flow5L/min) Circulating fluid pressure[MPa] 20 Outlet60Hz 0.2 20 Outlet60Hz 0.2 Pump head[m] 20 Pump head[m] 10 0.1 10 Outlet50Hz 0.1 10 Outlet50Hz Return port Return port 0.0
Note 1) Only type E (Reed switch) is applicable as an auto switch when mounting a housing of 10.
Clamp stroke Manufacturable Range of Body Options Clamp stroke 10 mm 20 mm 50 mm Applicable bore (mm) 12 to 40 12 to 63 50 to 63 Symbol 10 20 50 Bore size (mm) 12, 16 20 to 63 FN MF N F M Nil Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.