WH E-0.05 E-0.05 I 0 0 KA AL G port 8-J F K C-0.1 A NA F H S + Stroke ZZ + Stroke (mm) A AL Bore size Standard stroke range B1 C D E F GA GB H H1 I J K KA MM NA P RA S WA WB WH 20 20 20 W ZZ 40 30 27 Up to 300 50 35 32 Up to 300 63 35 32 Up to 300 19 27 27 6 7 7 44 55 69 139 162 162 26 32 38 14 18 18 1/8 1/4 1/4 16 20 20 8 9 9 25 30 32 87 102 102 2 2 2 25 30 30 22<19> 26<24> 26<24> 15 17
Note 2) Since sizes 20 and 25 have a body with B type (through hole) and A type (double end tapped) in common, there is no A type part number. Example) RQA 20-30 does not exist.
, 25 Mounting nut Rod end nut G1 G2 NN 2-P I NA D J N2 N1 MM A F S + Stroke F H ZZ + Stroke (mm) Bore size (mm) A D NN F G1 P G2 MM S I ZZ H J N1 N2 NA M5 x 0.8 16 15 4 8 15 6 M12 x 1 M4 x 0.7 65 18.5 101 28 11 20 16 10 M5 x 0.8 22 15 5 10 15 6 M14 x 1 M5 x 0.8 74 22 114 30 12 21 19.5 16 Rc 1/8 28.5 18 8 13 25 8.5 M20 x 1.5 M8 x 1.25 97.5 31.5 151 40.5 20.5 33 29 20 Rc 1/8 32 18 10 13 30
Power supply output VI: 20 [kVA] Q = P = V x I x Power factor In this example, using a power factor of 0.85: = 20 [kVA] x 0.85 = 17 [kW] Cooling capacity = Considering a safety factor of 20%, 17 [kW] x 1.2 = W Efficiency Q = P = In this example, using an efficiency of 0.7: 13 0.7 = = 18.6 [kW] Cooling capacity = Considering a safety factor of 20%, 18.6 [kW] x 1.2 = 22.3 [kW] 20.4 [kW] *1
Note 2) Since sizes 20 and 25 have a body with type B (Through-hole) and type A (Both ends tapped style) in common, there is no type A part number. Example) RQA 20-30 does not exist.
Models (mm) Internal volume (L) Number of arranged elements Weight (kg) Element length (L) Model N (Port size) G W A B C D E F H J K P 25 (1B) 40 (1 1/2B) 50 (2B) 20 (3/4B) 20 (3/4B) 500 4 250 20 70 15 330 216.3 230 490 660 965 80 120 25 (1B) 40 (1 1/2B) 50 (2B) 20 (3/4B) 20 (3/4B) 500 4 500 20 80 24 330 216.3 230 490 905 1220 80 120 25 (1B) 40 (1 1/2B) 50 (2B) 20 (3/4B) 20 (3/4B) 500 4
Connector C Actuator side (Terminal no.) 1 2 5 6 (8) (14) (18) Cable length (L) [m] A1 B1 (13.5) (17.7) (17.7) 1 1.5 3 3 5 5 8 8 A 10 B 15 C 20 1 2 A6 B6 (30.7) Connector A 15 16 (14.7) Connector D L (11) (10) 8 A B C LE-CP/Cable length: 8 m, 10 m, 15 m, 20 m ( Produced upon receipt of order) Driver side (14.2) Connector C (Terminal no.) 1 2 5 6 (5.5) (6.3) Produced upon receipt of order
As a result, it will not be possible to verify it with the vacuum switch. In such a case, it is necessary to use an ejector that is suited to the nozzle and to select a vacuum switch with a favorable hysteresis and precision. 3.
Dual Rod Cylinder 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 RoHS Cylinder suitable for pushing , lifting , or clamping 48% Reduced by up to Overall length 59.5 mm 114 mm JMGPM25 20 mm stroke (20 x 2)1 CXSM20 20 mm stroke (20 x 2)1 JMGP25 CXSM20 59.5 mm 38% Reduced by up to 54.5 mm shorter (Compared at a 20 mm stroke) Weight 0.8 kg 1.28 kg CXSM32 25 mm stroke (32 x 2)1 JMGPM40 25 mm stroke (
WA + Stroke/2 Z X 4 x YY depth YL GD 40 Bottom view WA + Stroke/2 Z 2 x P (Plug) 4 x MM depth ML 4 x OA through 4 x OB counterbore depth OL L (OL) 4 x NN through U X PW PE VA 2 x P (Plug) H T R 2 x P D GB GC S Q 2 x P (Plug) GA JC PD C + Stroke FB FA K J G A + Stroke [mm] Bore size Standard stroke A C D FA FB G GA GB GC GD H J JC K L MM ML NN Nil TN TF 20 (16 x 2) 20, 30, 50 100, 150 38 27.5
H unit Use this unit when the cylinder is operated in a load and speed range above the L unit limit line and below the H unit limit line. 1000.5 1 2 3 4 5 100 10 30 20 0.5 1 2 3 4 5 10 20 30 m2 max. m1 max. m3 max. m1 max. m2, m3 max.
A IN OUT t A-A BLEED w y Note Component Parts Material No.
A G i 2 x P Port size G A 2 x P Port size b B Conduit DIN terminal D F Q S Cable 6 to 12 G1/2 F Q 280 D G1/2 45 (42) (44) 31.5 Built-in full-wave rectifier type R C C R E J J E 2 x M depth 5 H 2 x M depth 5 B B1 H G A G A B B1 2 x P Port size 2 x P Port size Bracket mounting hole a1 (VXS23, 25) a a1 (VXS24, 26) 6.5 10.5 Dimensions (mm) Model Port size P A B B1 C D E F G H J M Bracket mounting
x 0.8 MM D D FY FB H + Stroke Z + 2 x Stroke S + Stroke NA F NA FT F A H FZ FX A 2 x FC Mounting hole C B 0 0.3 B 0 0.3 Drawing of view E (mm) Bore size 16 10 15 15 B GA FX FT F A 18.3 15 C 20 17 5 4 8 8 5.5 5.5 2.3 2.3 33 33 20 20 5 5 FB FY D FC FZ 12-0.027 10-0.022 H NA NDh8 Z S NN 11 11 17.5 19 66 65 M12 x 1.0 M10 x 1.0 MM 42 42 GC 0 M4 x 0.7 28 28 122 121 20.5 20.5 0 M5 x 0.8 Specific
9 G 8.5 10.7 15.5 LW 120 176 229 M 9 12 16 N 20 25 40 NC 14 21.3 32.4 A 80 105 165 B 9.5 14 17.5 C 5.4 8.6 10.8 LB 87.4 124.7 148.3 LE 5 6 8 (LL) 40 49.6 75 LD 5.5 9 11 Model MY2HT16G MY2HT25G MY2HT40G P M5 x 0.8 1/8 1/4 PF 10 12 20 PC 4 9.4 8.5 PD 23 29.2 36 PG 10 12.5 20 PH 10.2 13 18.5 PI 41 57.6 72 PA 44 63 113 PB 80 110 132 PE 1 3.4 0.5 R 5 8 12 RR 5.3 8.5 11 RW 69 100 116 SS 9.7 14
Select between two values 2-A or 1-A using the + and keys. The value 2-A indicates a double acting actuator and 1-A a single acting actuator. To conclude press the ?
Applicable bore A J L B C D E F G H 0.25 K 1/4-28 NY-075 0.51 1/4-28 0.94 1.18 0.69 0.25 0.51 0.71 0.16 3/4", 7/8" NY-106 0.51 0.25 5/16-24 5/16-24 0.94 1.18 0.69 0.25 0.51 0.71 0.19 1 1/16" NY-125 0.75 0.38 7/16-20 7/16-20 1.31 1.69 0.94 0.38 0.75 1.02 0.25 1 1/4", 1 1/2" NY-G050 0.75 0.38 1/220 1/2-20 1.32 1.69 0.94 0.38 0.75 1.02 0.31 2" Material: Carbon steel Jam nut (Rod thread) (in)
15.5 30.15 VDW2 M5, 1/8 4 33 14 39 20 17 36.2 2 x J thread depth K VCH VDW VDW Body material Stainless Steel SX10 2 x 3.4 Mounting hole W Y Grommet VQ LVM X U D 300 Q F Full wave rectifier (AC type) [mm] C R E G Mounting method Model Port size P A B B1 C D E F J K M VDW1 M5 12 20 10 42.4 15 6 11 M2.5 4 11 VDW2 M5, 1/8 15 22 11 51.7 20 8 13.5 M3 5 15 B B1 2 x P Port size A Mounting bracket
Bracket (Option) Optional Specifications J: With drain guide u I T: With element service indicator T Maintenance , Drain space Dimensions with mounting bracket E~ment service indicator B E F G H I J Model Port size A C D K L M N 0 P Q R S T U 5 9 5.5 35 54 70 26 4.5 1.6 24 37 AMH150 1/8, 1/4, 3/8 159 20 63 20 76 20 76 20 90 20 90 20 106 20 106 20 122 20 160 10 166 56 15 10 187 66 20 10 187
Analog Output Flow/Analog output Output A B C Voltage output 1 V 1.1 V 5 V Current output 4 mA 4.4 mA 20 mA C Model Rated flow [L/min] Minimum Maximum LFE1 0.5 20 LFE2 2.5 100 LFE3 5 200 B A Outside the range 0 Min.