Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.

The rotation range under the adjustment of an angle at 60 is indicated below. The rotation range under the adjustment of an angle at 60 is indicated below. e g n R a o r t e a n ti g o o ti n n a a r t a o r n R g n e o ti a Note) If it is pressurized by the port indicated with the arrow, the shaft rotates in the clockwise direction.

Regulator AWM20/30/40 Series AWM is a component made up of a regulator and a mist separator that are integrated to provide optimum results in applications such as clean-air blow operations.

range m 190 40 10 20 10 1 2 3 7 20.9 22.8 24.4 28.7 16.9 18.8 20.4 24.7 A A 190 35 10 20 10 190 30 10 15 10 When D-F9 is used 190 25 10 15 10 Rotation range m: Value of the operating range Lm of a single auto switch converted to an axial rotation angle.

It is an assembly of a piston and a gasket (KSYP-13).

circuit When performing an intermediate stop of a load using an air pressure circuit, operate at or below the kinetic energy shown in the table below.

8) * Including grounding cable 40 *1 An example of the cable specifications is when two kinds of vinyl insulated wires with a continuous allowable operating temperature of 70C at 600 V, are used at an ambient temperature of 30C.

Never use them in the presence of an explosive gas, as this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside cylinders will become demagnetized. (Please consult with SMC regarding the availability of a magnetic field resistant auto switch.) 3.

Never use them in the presence of an explosive gas, as this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside cylinders will become demagnetized. (Please consult with SMC regarding the availability of a magnetic field resistant auto switch.) 3.

M24 x 1.5 K M6 x 1.0 M8 x 1.25 40 145 115 75 60 31.5 30 20 24 M30 x 1.5 A M8 x 1.25 M10 x 1.5 50 185 145 95 80 40 40 25 26 M39 x 1.5 Note) The pin, keeper plate and cap bolt are included with a double knuckle joint.

Description Size 1 Valve Rc1/2 2 Valve Rc1 3 Y-strainer (#40) (Accessory)* Rc1 4 Flow meter Prepare a flow meter with an appropriate flow range. 5 Valve (Part of thermo-chiller) Rc1/4 6 Pressure gauge 0 to 1 MPa 7 Y-strainer (#40) or filter Rc1/2 8 Valve Rc3/8 9 Y-strainer (#40) or filter Rc3/8 * If foreign objects of 20 m or larger may enter, install a particle filter separately.

Note 3) Operate an interface regulator only by applying pressure from the P port of the base, except when using it as a reverse pressure valve. To combine a pressure center valve and the A and B port pressure reduction of an interface regulator, use the ARBF3000, 4000, or 5000 model.

(mm) B 28.5 28.5 29.5 32.5 40.5 40.5 Hs 24.5 27 30.5 35 40.5 47.5 A 30 30 31 35.5 43 43 B 28.5 28.5 29.5 32.5 40.5 40.5 B 22.5 22.5 23.5 26.5 34.5 34.5 B 25.5 25.5 26.5 29.5 37.5 37.5 Hs 27 29.5 33 37.5 43 50 A Hs 27 30 33.5 38 43.5 50.5 A 27 27 28 32.5 40 40 Hs 27.5 30 33.5 38 43.5 50.5 CS1 20 25 32 40 50 63 24 24 25 29.5 37 37 C76 C85 C95 D-H7 D-H7W D-H7C D-H7BAL A 29 29 30 34.5 42 42

Fig.1 Equivalent circuit of a NPN type switch with the output off Fig.2 shows an equivalent circuit of a NPN switch with the output on. In this circuit the load is powered. When using a PLC, the input section sees a low level. Another type of a switch output is a PNP switch. Refer to Difference between NPN and PNP Output on the next page.

leakage from the rod section directly into the outside of clean room by relief port and making an actuators rod section having a double seal construction.

Avoid touching the switch directly as this may cause a burn. Operating Environment Warning 1. Never use in the presence of explosive gases. The switches do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. 2.

If driving a load such as a relay that generates a surge voltage, use a switch with a built-in contact protection circuit or use a contact protection box. 1) For an auto switch without a contact protection circuit, use a contact protection box when the wire length is 50m or longer.

Avoid using in a tightly shut container. Install it in a well-ventilated area. Furthermore, do not touch it while it is being energized or right after it is energized. 2) Install an air filter. Install an air filter close to the valve on the upstream side. A filtration degree of 5 Mm or less should be selected. 3) Install an aftercooler or air dryer, etc. 3.

When a surge generating a load such as a relay or solenoid is directly driven, use a type of switch with a built-in surge absorbing element. 4. Since the type of fluid varies depending on the product, be sure to verify the specifications. The switches do not have an explosion proof rating. To prevent a possible fire hazard, do not use with flammable gases or fluids. 5.