SMC Corporation of America
Elite Part Number Search
Search Results "IDF2E-10-AS"

As the flow rate when Kv = 1 is calculated as the formula: Q0 = 15 x 1/1.5 = 10 [L/min], read off P when Q0 is 10 [L/min] in Graph (2). The reading is 0.036 [MPa]. Example 2) Obtain the saturated steam flow rate when P1 = 0.8 [MPa] and P = 0.008 [MPa] with a solenoid valve with a Kv = 0.05 [m3/h]. Read off Q0 when P1 is 0.8 and P is 0.008 in Graph (2), the reading is 20 kg/h.

Host STX 36H Offset ETX Check sum CR Symbol 100 10-1 10-2 (H) (L) Thermo-con ACK CR Note) As for symbols, minus is indicated by -(=2DH) and plus is indicated by 0(=30H).

Operating Parameters Status Gas Operating pressure Proof pressure Burst pressure Ambient and operating temperature Cv Vacuum to 250 psig (1.7 MPa) Vacuum to 125 psig (0.9 MPa) 1000 psig (6.9 MPa) 8000 psig (55.2 MPa) 14 to 160F (10 to 71C) (No freezing) 1) 0.29 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 2) 4 x 10-9 Pam3/sec 2) Ra max 15 in. (0.4 m) Option: 10 in. (0.25 m), 7 in. (0.18 m), 5 in

P2 P2 IF 10 [ms] 10 [ms] 100 Disconnected Data ON-OFF output Time ON Time Normal mode ON OFF OFF Time Time Operate in the manner same as ordinary since auto shift function is not used. Certain switching can be obtained by selecting the output corresponding to the nozzle as the graph above.

Dedicated grounding should be used as much as possible. Grounding should be to a type 3 ground. (Ground resistance of 100 or less.) 3. Use a wire with a sectional area of 2 mm2 or larger for grounding. Grounding should be as close as possible to the controller, and the ground wires should be as short as possible. 4.

50 Safety distance (mm) 40 Operational range 30 l1 20 l1 Dangerous range 10 0 5000 10 15000 20 Welding current (A) l2 50 Safety distance (mm) 40 30 l2 l2 Operational range 20 10 0 5000 10 15000 20 Welding current (A) 32 SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK EUROPE SPAIN/PORTUGAL SMC Espaa, S.A.

Other dimensions are the same as double acting, single rod, standard type. (: Same as the standard.)

OAllowable voltage fluctuation is 10% of the rated voltage.

Target position: 100.000[mm] (=10 [m] = 186A0h) Target speed: 100[r/min] (=10 [0.01r/min] = 2710h) Acceleration time constant: 100 [ms] (= 64h) Deceleration time constant: 100 [ms] (= 64h) The setup value is as follows.

/Flange Rod end width across flats 10 10 21 21 46 46 Data Part no.

Set the mounting band perpendicularly to cylinder tube. 20 50 63 80 100 25 32 40 D-B7/B80 8 10 9 10 10 11 D-B73C/B80C D-C7/C80 8 10 9 10 10 11 D-C73C/C80C 8 10 9 10 10 11 D-B5/B64 11 11 MX Mounting correctly Mounting incorrectly 13 13 14 14 14 17 D-B59W 18 16 D-G79/K79 8 10 9 10 10 11 Auto Switch Mounting Bracket Part No.

5 $0 @8 #7 #6 $1 F G Area G (10) Enlarged view F 10, 15 w u i o !1 #2 q !3 r y e @6 @5 @3 $1 #0 @7 #1 10 Component Parts Note No. Description Material No.

10 12 16 20 5 6.5 8 10 14 15 18 20 7 10 12 14 4 4 5 5 5 5 8 10 * Refer to P.2.3-18 for detail of the rod end nut and mounting brackets.

With the setting of 5-10-15 so on and so forth, error (Err5:Date error) will occur, as the distance between present stopping position and next stopping position will less than 5mm, due to the exist of setting points tolerance.

Double clevis type mm Bore size (mm) Stroke range (mm) CD hole H10 Shaft d9 CL CD CT CU CW CX CZ L A B 63 107 55 30 to 100 93 14 8 20 30 22 44 8 80 129.5 63.5 40 to 100 111.5 18 10 27 38 28 56 10 100 155 76 L CU CW RR 40 to 100 133 22 13 31 45 32 64 12 CX CZ +0.4 +0.2 0.1 0.3 B + Stroke CL + Stroke A + Stroke Bore size (mm) Stroke range (mm) 10 to 50 75, 100 10 to 50 75, 100 10 to 50 75,

12 12 16 16 20 6.6 6.6 9 9 11 11 38 41 50 52 66 76 51 54 65 67 86 96 10 10 12 14 18 20 21 24 33 37 47 55 7 9 11 11 12.5 13.5 18 22 30 35 40 50 26 28 32 40 50 60 31 35 45 50 60 70 32 36 45 50 63 71 8 10 12 12 14 15 10 11 12 15 15 19 32 40 50 63 80 100 11 11 15 15 18 18 10 12 16 16 20 20 21 24 33 37 47 55 8.5 8.5 10.5 10.5 11.5 12.5 10 10 12 12 14 15 6.6 6.6 9 9 11 11 38 41 50 52 66 76 18 22

Consider selecting a ZNC series (body size 20) Bernoulli gripper as a substitute. Click here for details.

51.4 ZH18DA-10-12-12 15.9 18.5 18.5 10 12 12 15.6 17 17 105.7 60.9 28.4 26.4 22 22 10 8 Refer to the standard bracket dimensions.

Option L . 10-1 10.1 SAFETY INSTRUCTIONS FOR USE . 10-1 10.2 SPECIFICATIONS . 10-1 10.3 MOUNT THE HEAVY DUTY AUTO DRAIN . 10-2 10.4 MAINTENANCE . 10-2 Chapter 11 Option R .11-1 11.1 SAFETY INSTRUCTIONS FOR USE . 11-1 11.2 EARTH LEAKAGE BREAKER SPECIFICATION . 11-1 11.3 CONNECTION OF POWER SUPPLY . 11-2 Chapter 12 Option T . 12-1 12.1 SAFETY INSTRUCTIONS FOR USE . 12-1 12.2 OPERATION / ERROR