A cm Cylinder conductance With length L (cm) and diameter D (cm) where L>>D, from the formula C=(2RT/M)0.5D3/6L, the conductance C=12.1D3/L l/sec, at an air temperature of 20C. ON OFF Short pipe conductance From the Clausings factor K and the hole conductance C in the drawing below (Clausings factor drawing), the short pipe conductance CK is easily found as CK=KC.

Cylinder conductance With length L (cm) and diameter D (cm) where L>>D, from the formula C=(2RT/M)0.5D3/6L, the conductance C=12.1D3/L l/sec, at an air temperature of 20C. Short pipe conductance From the Clausings factor K and the hole conductance C in the Drawing 1. (Clausings factor drawing), the short pipe conductance CK is easily found as CK=KC.

Vacuum Pump, HP 1/2 hp, Displacement 1.2 cfm, End Vacuum 0.05 torr, NPT Inlet 3/8 in, Voltage 115, Amps AC 3, Overall Length 18 in, Overall Height 18 in, Overall Width 9 in, 60 Hz, 1 Phase, Weight 50 lb, Max. dBA 55, Application For Schlenk Line Drying Manifolds, Vacuum Ovens, Freeze Dryers Up to 6L, Centrifugal Concentrators

Auto Switch Mounting Except for D-P5DWL D-P5DWL Auto switch mounting screw Hexagon socket head cap bolt With SW M3 x 0.5 x 5l M3 x 0.5 x 6l Auto switch Switch mounting bracket With SW, M3 x 0.5 x 14l Round head Phillips screw 8 x 3.3 x t0.8 Flat washer Auto switch Auto switch mounting nut Auto switch mounting nut Tightening torque of auto switch mounting screws should be 0.5 to 0.7Nm.

. -13No.PS-OMV0004-H Mounting and Installation Installation Mounting with bracket Mount the bracket to the body with mounting screws (Cross recessed round head screw: Nominal size M4 x 6L (2 pcs.)), then set the body to the specified position. : Tighten the bracket mounting screws to a torque of 0.760.1 Nm.

. -14No.PS-OMV0009-E Mounting and Installation Installation Mounting with bracket Mount the bracket to the body with mounting screws (Cross recessed round head screw: Nominal size M4 x 6L (2 pcs.)), then set the body to the specified position. : Tighten the bracket mounting screws to a torque of 0.760.1 Nm.

. -12No.PS-OMW0002-C Mounting and Installation Installation Mounting with bracket Mount the bracket to the body with mounting screws (Cross recessed round head screw: Nominal size M4 x 6L (2 pcs.)), then set the body to the specified position. : Tighten the bracket mounting screws to a torque of 0.760.1 Nm.

Order a stainless steel screw kit (BBA1) separately, and use the M4 x 6L stainless steel set screws included in the BBA1. Note 4) There is a difference in the cylinder tube thickness depending on the cylinder model. When a band mounting type is used as an applicable auto switch and a cylinder model is changed, use caution.

Order a stainless steel screw set (BBA1) separately, and select and use the M4 x 6L stainless steel set screws included in the BBA1. 696 Auto Switch Mounting CE2 Series Besides the models listed in How to Order, the following auto switches are applicable. Refer to pages 941 to 1067 for detailed specifications. Auto switch type Part no.

In the above state, set the approximate auto switch mounting sections, then, using a hexagonal wrench, tighten the mounting screw (M3 x 6L) that is an accessory to BHK-032. 4. After confirming the detecting position, tighten the mounting screw (M2.5) for the auto switch to keep it in place.

M3 x 0.5 x 6L M3 x 0.5 x 8L M3 x 0.5 x 10L BMU-1-025 BQ-1 BQ-2 1 1 1 Note 3) Auto switch mounting brackets and auto switches are packed together at cylinder shipment. Auto switch mounting screws 1 D-A7/A8 D-F7/J7 BBA2 Auto switch mounting nuts (square nut) 2 M3 x 0.5 1 BQ-1 Auto switch mounting nuts (convex) 3 M3 x 0.5 1 BQ-2 Spacers (black resin) for BQ-2 are not included.

6.7 MX 2-M3 x 0.5 thread depth 3.5 (Piping port) 20 MTS 20.5 5.5 MY Stroke 42 + Stroke CY 5.5 4.5 13.4 32 + Stroke MG 5 + Stroke 12 2.75 11 1.2 M3 x 0.5 x 3l (Hexagon socket head set screw) M8 x 1.25 x 7.5l (Bolt holder) CX 0.5 D-X 25 0.2 25 0.2 5.3 5.3 16 32 31 20Data 2-M3 x 0.5 through 3.4 through 6.5 counterbore with depth 5 (Opposite side: Same) 5.5 2-M3 x 0.5 through M2.5 x 0.45 x 6l

A cm 2 7 Ultimate Pressure Cylinder conductance With length L (cm) and diameter D (cm) where L>>D, from the formula C=(2RT/M)0.5D3/6L, the conductance C=12.1 D3/L (L/sec) at an air temperature of 20C. Ultimate pressure P (Pa) is P=Q/S, where the sum of Weight flow rates for outgassing (Qg) and leakage Q(L) is Q(Pam3/s), and the exhaust speed is S(m3/s).

A cm 2 7 Ultimate Pressure Cylinder conductance With length L (cm) and diameter D (cm) where L>>D, from the formula C=(2RT/M)0.5D3/6L, the conductance C=12.1 D3/L (L/sec) at an air temperature of 20C. Ultimate pressure P (Pa) is P=Q/S, where the sum of Weight flow rates for outgassing (Qg) and leakage Q(L) is Q(Pam3/s), and the exhaust speed is S(m3/s).

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com M3 x 0.5 x 3l (Hexagon socket head set screw) M8 x 1.25 x 7.5l (Bolt holder) CX 0.5 D-X 25 0.2 25 0.2 5.3 5.3 16 32 31 20Data 2-M3 x 0.5 through 3.4 through 6.5 counterbore with depth 5 (Opposite side: Same) 5.5 2-M3 x 0.5 through M2.5 x 0.45 x 6l (Hexagon

MLU ML1C DMounting of Auto Switch -X Except D-P5DWL D-P5DWL 20Data Auto switch mounting screw Hexagon socket head cap bolt With SW M3 x 0.5 x 5l M3 x 0.5 x 6l Auto switch Switch mounting bracket With SW, M3 x 0.5 x 14l Round head Phillips screw 8 x 3.3 x t0.8 Flat washer Auto switch Auto switch mounting nut Auto switch mounting nut Tightening torque of auto switch mounting screws should

Reservoir for filter series FN1; Tank capacity: Model 4102=6L; Port size: Rc 2; Material (bowl & cover): SUS304; Material (O-ring): NBR or FPM

Note) For detailed specifications on the IS10 series, please refer to the section of our website IS10 series, http://www.smcworld.com T-shaped Spacer: (T) 1/8, 1/4, 3/8 E Using a T-shaped facilitates the branching of air flow.

Model AMR3000 AMR4000 AMR5000 AMR6000 Model name 1 4 3 8 1 2 : E4-02 : E4-03 : E4-04 1 4 1 2 : E6-06 : E6-10 3 4 : E3-02 : E3-03 : E5-04 : E5-06 Adapter assembly (7) 3 8 3 4 1 AD33-X203 AD33-X202 AD33-X210 AD33-X201 Float type auto drain (AMR 100) (8) IS10-01 (0.4 MPa setting) Compact pressure switch 135510 135613 Elbow (R x Rc) (9) Note 5) in the gauge part number (e.g.