A Note 1) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12

A Note 1) 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12

D. 9 to 11:P368010-27 View A 100 46 30 2 14 IP8000-01 (With terminal box) OUT2.Rc1/4 With plug 110 38 192 218 23.5 110 40 35 OUT1.Rc1/4 SUP.Rc1/4 2 x M8 x 1.25 depth12 (Female thread for side mounting) 43 23.5 58 38 39 11 9 39 OUT2 MPa 42 162 117 16 6.1 MPa 20 50 65 A 122 ELECTORO PNEUMATIC IP8000 P O S I T I O N E R 22.5 125 At accessory E: 110 At accessory F: 110 { } 5 150 125 12 168 8

Connection thread 1/8 1/4 3/8 1/2 3/4 1 5.2 to 6.6 8.9 to 10.3 16.2 to 17.7 20.7 to 22.1 20.7 to 22.1 26.6 to 28.0 Installation and Adjustment Torque (7 to 9) (12 to 14) (22 to 24) (28 to 30) (28 to 30) (36 to 38) Warning Air Supply 1. Confirm the symbols 1 and 2 before the Warning valve is connected. The port marked 1 is the air inlet and the port marked 2 is the outlet.

A Station 2 14 SOL. A Station 3 2 VQD 1 SOL. A Station 4 14 15 2 SOL. A 15 3 3 4 5 6 7 8 9 10 11 12 13 Station 5 16 17 18 19 20 21 22 23 24 25 SOL. B 16 SOL. A 4 Station 6 SOL. B DIN rail mounting bracket [-D] VVQ1000-57A for {F, L, M, P, S (EX500) kit} VVQC1000-57A-S for {S (EX250) kit} VVQC1000-57A-T for {T, S (EX126) kit} 17 SOL. A 5 Station 7 SOL. B 18 SOL. A 6 Station 8 SOL.

The calculalion of standard piston speed for kinetic energy at load is ihe average speed x1.2. 225 0 14.s (01) 29 (0.2) 43.5 (0.3) 58 (0.4) e The relation between speed and load is as illustrated below. The range of kinetic energy is under the lineO Al locking. lock-up unit absorbs not only kinetic energy. but also thrust of cvlinder itself.

seals Type of actuation Cylinder port size 2 position 3 position One-touch fitting Pressure center Effective area mm (Cv factor) Exhaust center Closed center Series C3 C4 C6 (6) M5 (3.2) (4) Double Single VQ130 Metal seal VQ131 Rubber seal 4.5 (0.25) 6.3 (0.35) 54 Series VQ1000 How to Order Manifolds VV5Q13 (-00T) J Series VQ1000 P, R port inch bore size Stations Options Symbol Stations 01

No.SYJ300-OMU0003 SYJ Series EX510 Assy (SY3000-37-81A--N) SY3000-44-3A1 8 SYJ300 (SY3000-37-81A--) Assy 8 SY3000-37-81A-2-N 14 SY3000-37-81A-2-5 3 14 21,32SA SS5YJ3SY3000-37-81A-1-N 58 SYJ300 M1.7 0.12N.m SY3000-37-81A-1-4 3 58 SYJ500 M2.5 0.45N.m 42,43SA SY3000-37-81A-2-N 18 20,40, SS5YJ5SYJ700 M3 0.8N.m SY3000-37-81A-2-5 3 18 SY3000-37-81A-3-N 18 21,41SA SS5YJ7SY3000-37-81A

The calculalion of standard piston speed for kinetic energy at load is ihe average speed x1.2. 225 0 14.s (01) 29 (0.2) 43.5 (0.3) 58 (0.4) e The relation between speed and load is as illustrated below. The range of kinetic energy is under the lineO Al locking. lock-up unit absorbs not only kinetic energy. but also thrust of cvlinder itself.

VCHC Connection Female Thread: Rc, NPT, NPTF ASR ASQ Uni thread size Wrench tightening angle after hand-tightening [deg] Tightening torque [Nm] 1/8 30 to 60 3 to 5 1/4 30 to 60 8 to 12 3/8 15 to 45 14 to 16 1/2 15 to 30 20 to 22 3.

Thread type Port size Nil Rc N NPT 01 1/8 02 1/4 Related Equipment Check Valve INA-14-290/XTO-674Water Strainer Series WF300 Body material: Bronze Mesh: 100/70/50/25 mesh 14-E628 Body material: Brass Best Pneumatics Port size: Rc1/8 Port size: Rc1/4, 3/8, 1/2 WR110--X224/WR110--X215 14-E627 WR110--X224/WR110--X215 Flow Rate Characteristics Conditions/Fluid: Water, Port size: Rc1/4 WR110-02

-7No.IZ*-OMU0031 LCD (OUT1)() (OUT2)() (OUT1)() OUT1ON (OUT2)() OUT2ON LCD 4 ON/OFF ON/OFF -8No.IZ*-OMU0031 (2 m)ZS-28-A (1 )ZS-28-C 0.140.2mm 0.81.0 (M3X5 L(2))ZS-28-B (M3X8 L (2 ))ZS-27-C (M38 L(2))ZS-27-D ZS-27-01 -9No.IZ*-OMU0031 M3X5 L(2) 0.50.7 Nm M3X5L (ZS-28-B) M3X5L M3X8 L(2 ) M3X8L ( ZS-27-01) (ZS-27-C) 90 2 -10No.IZ*-OMU0031 ,FG 20mm () SMC 3M ZS-28-C 37104

1 / 02 2 S / 1 S 12 12 PV PD 2 PD PVPD 01 Rc1/8 M5 M50.8PVPD 01N NPT1/8 2 01F G1/8 M5 M50.8 M50.8 M-5P ZB03 ZB04 ZB05 ZB06 PV N.C.

ZS-35-01 -10No.PS-OMU0008CN-D OUT1 LCD OUT2 () LCD 4 ON/OFF ON/OFF (kPaMPa) -11No.PS-OMU0008CN-D digit() 1digit=1kPa 1,2,3,,99,100 1kPa -0.1001.000[MPa]F.S.=1.000(-0.100)=1.100[MPa] (1F.S.=1.1000.01=0.011[MPa]) F.S. ( 1.000[MPa]5R.D.1.000[MPa]50.05[MPa] 0.800[MPa]5R.D.0.800[MPa]50.04[MPa] R.D.

Thread type Port size Nil Rc N NPT 01 1/8 02 1/4 Related Equipment Check Valve INA-14-290/XTO-674Water Strainer Series WF300 Body material: Bronze Mesh: 100/70/50/25 mesh 14-E628 Body material: Brass Best Pneumatics Port size: Rc1/8 Port size: Rc1/4, 3/8, 1/2 WR110--X224/WR110--X215 14-E627

Double acting Body Applicable option Actuator section End plate PPS Diaphragm Port size Symbol Note 1 2 3 4 VN Symbol 01 02 01 02 02 03 03 04 04 06 10 Port size 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 1/2 3/4 1 Body class Stainless steel PTFE A 1 Note) Refer to Variations in the table below for valve type combinations.

Series VC 2 3 4 Class 2 Class 3 Class 4 OUT port size VDW Port size 1/8 (6A) Symbol 01 02 Stations Uside D side 1/4 (8A) Material VQ Stations 1 2 3 4 5 n 02 2 stations All IN ports are 3/8.

.3I5 f.0[0/-.01[ t,?5 .88 1 \ l 1 PM/PR0r25(,|r(S) 6.59 .251 +.005/..000 .251 + 005/ 000 .500 +.000/-.010 .500 +.000/..010 N/A 1.50 N/A .88 .23 .93 .44 L6 9.22 ,dd .44 Note: (SJ Indicales modelcomes wltn sprine. All dimensLons Ln Lnches.

Refer to pages 16-14-3 and 16-14-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 16-1-11 to 16-1-13 for Precautions on every series. Wiring Pressure Source Warning Warning 4. How to connect contact protection box Connect the lead wires from the body and the contact protective box side indicated SWITCH.