AS2002F-04 When connecting 4 pcs. and mounting L-brackets on both sides Speed controller AS2002F-04 4 pcs. L-bracket AS-20L 2 pcs.
M M5 M5 x 0.8 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 Thread connection H/DL L/LL KC Applicable tubing O.D. Same dia. tubing 4 6 8 10 12 04 06 08 10 12 4 6 8 10 12 KK Tubing (rod) connection Different dia. tubing (plug-in reducer) KK130 DM Construction KDM KB KR KA KQG2 KG KFG2 MS KKA M5 type Male connector KP KP Description Material Component Parts LQ No.
Ground wire (1.5 m)/Accessories IZH-A-01 High-voltage measuring handle/Option IZH-C-01 Soft case/Accessories IZH-B-01 High-voltage measuring handle Ground wire Soft case Note) Be sure to use a high-voltage measuring handle in situations such as during high-voltage measurement when there is a possibility of personnel coming in contact with electricity.
AME Digital flow switch AMF Measured flow range 5 to 100 L/min 50 to 500 L/min Nominal filtration rating: 0.01 m (Filtration efficiency 99.99%) Measured flow range 5 to 100 L/min 50 to 500 L/min Nominal filtration rating: 0.01 m (Filtration efficiency 99.99%) Filter Restrictor Regulator ZFC SF SFD LLB LLB AD GD Nominal filtration rating: 0.01 m Nominal filtration rating: 0.01 m (Filtration
Description IR1000 IR3000 IR3020/3120 IR2020/2120 IR3010 IR1020 IR2000 IR2010 IR1010 Bracket Pressure gauge P36203018 P36202028 P36201023 G43-2-01 G43-4-01 G43-10-01 G43-4-01 G43-10-01 G33-4-01 G33-10-01 G43-2-01 G33-2-01 Accuracy 3% (Full span) 14-5-7 7 Series IR1000/2000/3000 Construction IR1000 IR2000 IR3000 q i o !4 q o i !
Terminal PSE200A/PSE201A PSE202A/PSE203A q DC (+) L+ w DC () L e CH1_OUT1 C/Q (CH1_OUT1) r CH1_OUT2 t CH2_OUT1 y CH3_OUT1 u CH4_OUT1 i Auto-shift input N.C. 2000 Power supply with M12 connector/Output cable (Made to Order) * For use when using an M12 connector for IO-Link communication Connector pin assignment Pin no. 7 N.C. 8 N.C. 1 Brown: L+ Sheath O.D. 3.5 Connector size M12 2 White: CH1
For vacuum/ compound pressure ZSE30A 01 N M ISA2 Option 3 Note) Calibration certificate Nil Y K T Note) Operation manual ISE35 Symbol Rated pressure range ZSE30A ZSE30AF 0 to 101 kPa 100 to 100 kPa PSE Piping specifications IS 01 Note) All texts in both English and Japanese.
Pod NVF3000 NVF5000 Supply SUP Cylindet cYL.1, CYL.2 A , B Exhaust EXH.1, EXH.2 Rl, R2 Symbol (SirEle solenoid) l c 1 : c Y L . 1 l IC2:CYL.2 lEl :EXH.r I {E2:EXH.2] Lubricant 1.
1 Filter Bowl assembly Lubricator AF11-2 AF11-3 AL12-2 AL12-3 14-3-11 2 Series AU Flow Characteristics Inlet pressure: 1.0 MPa Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Pressure Characteristics Inlet pressure: 0.7 MPa, Outlet pressure: 0.2 MPa, Flow rate: 20 l/min (ANR) Outlet pressure (MPa) Outlet
1 Filter Bowl assembly Lubricator AF11-2 AF11-3 AL12-2 AL12-3 14-3-11 2 Series AU Flow Characteristics Inlet pressure: 1.0 MPa Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Pressure Characteristics Inlet pressure: 0.7 MPa, Outlet pressure: 0.2 MPa, Flow rate: 20 l/min (ANR) Courtesy of Steven Engineering
2 i r i t y w w e !0 !0 !2 !5 o !0 !4 q q y u !1 !3 r t !1 M5 type U10/32 type M5 type U10/32 type !1 y !2 u !4 !3 i !5 u e r r t w e o !0 i o q q t y !0 !2 w !
ZS-22-B Response frequency 200Hz 200Hz 200Hz 200Hz 200Hz 200Hz (5ms) (5ms) (5ms) (Sms) (Sms) (5ms) (With two M4 mounting thread) Noj. l) Hysteresis Adjustable AdjlJSlable A~uslable Adjustable A~US1ab' A~lJstabte mode m;1 Cf rm: (}i jl t(rml t~,~I~IIm] Cldj.t;,' II"mI l~j~Cf nn'e:, 1: &ij. orm::fe,1 Hysl21 esls Wmdow Fixed Fi xed Fixed Fixed Fixed Fixed co6:rearator m e (3digit) (3digit)
Regenerative option PA02 0 0(Non) / 0002(LEC-MR-RB-032) Rotation direction selection PA14 0 1(+Counter motors side) Load to motor inertia moment ratio PB06 7 7 Function selection E-3 PE41 0 0 LEFS25(L,R)T6 LEFS32(L,R)T7 LEFS40(L,R)T8 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
-06 AS121FG-U10/32-07 18.3 23.1 11.7 13.5 18.1 22.9 11.6 12 6 1/4" 13.5 AS221FG-01-04 AS221FG-N01-01 12.7 20.4 27.5 9.3 4 1/8" 16 20.4 27.5 17 9.3 12.7 AS221FG-01-06 AS221FG-N01-03 14.3 13.5 20.4 27.5 11.6 6 5/32" 14.2 31.1 36.1 12 32.1 27.1 NPT 1/8 R 1/8 17 AS221FG-01-08 AS221FG-N01-05 12.7 14.3 23.1 30.2 19 18.5 25.3 32.4 15.2 11.4 8 3/16" 36.1 31.1 32.1 27.1 16.5 14.2 AS221FG-01-10 AS221FG-N01
0.72 0.47 90 1.17 0.28 3.47 0.09 1/8 NPT 0.41 3/4-16 0.88 0.85 0.51 45 1.50 0.31 3.91 0.09 1/8 NPT 0.50 1 1/4-12 1.19 1.20 0.81 45 1.91 0.59 5.11 0.12 1/4 NPT 3 Series NCM-A Dimensions ZB + STROKE LB + STROKE 0.50 W K A L ZC 2-ZD MM YC WA N KK UNF-2A B -0.003 0.000 PILOT Y WB D ACROSS FLATS NN UNF 2A Bore MM KK A B D E F GA GB K L 075 (3/4") 0.250 1/4-28 0.50 0.624 0.86 0.38 0.250 0.75 0.34
L L L SOLV L L L L L L L L L L L L: Low fixed (0) Input status area Input status area specifications Item Status State 0 Normal SOLV State of power supply for solenoid valve 1 Abnormal (19 V or less) Output area mapping Output data Offset MSB LSB MSB LSB (Word) 15 8 7 0 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 -45No.EX-OMX1001 Dimensions -46No.EX-OMX1001
( DXT170-123-ALmm 1) 300 (+-) 6 600 10 1000 15 1500 20 2000 2) 25 2500 (1mm) 30 3000 8 No.VEX-OMY0001 VEX3 VEX3 12,22,32,42 DIN ACZ DCZ 1) 2) 3) () 4) DC No.1 (+)No.2 (-) () (904 ) 3.57 JISC3306 0.5mm22 3 DIN L,M AC AC DC DC AC DC 3 DIN AC DXT170-176-1 NO.1 NO.2 AC100V 100V DXT170-176-2-01 DC AC200V 200V DXT170-176-2-02 NO.1 AC110V 110V DXT170-176-2-03 (+) NO.1
How to Calculate the Flow Rate For obtaining the flow rate, refer to page 4-1-6. 4-16-1 2 Series VS3115/3110 How to Order VS311 D L 5 01 5 Thread type Accessory (Option) Nil Rc Mounting With indicator light L P With manual override N NPT T NPTF E Nil Without bracket Port size Piping Electrical entry B With bracket G 1 8 Rc 1 4 Rc 1 4 Rc 3 8 Without sub-plate Rc 01 02 02 03 00 Body ported
-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 L L VXA K VN K Conduit terminal: T LVC LVA F (Q) 34 LVH LVD LVQ 25 U LQ R C LVN G1/2 TI/ TIL E B A H D 2-P Port size (S) PA 2-M Thread depth N PAX L PB K (mm) Electrical entry P Port size B C A D E F H K L M N Grommet:G Conduit:C Conduit terminal:T Model Q R Q R Q R S U 13.5 28 64 1/8 31 6.5
OUT Standard specification Option Note) Water (Standard, up to 40C) Air (Standard, Dry) Turbine oil Vacuum (up to 1.3 x102 Pa) Carbon dioxide (CO2), Nitrogen gas (N2) Vacuum (up to 1.3 x101 Pa) (V, M) Non-leak (106 Pa m3/s or less) (V, M) IN N.O.