Pressure Range: 0 to 2 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 2 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 16 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 16 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: None, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: None
Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 2 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 2 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 16 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 10 MPa, Piping: NPT 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: None, Operation Manual/Calibration Certificate: Operation Manual + Calibration Certificate
3 SCREEN DIGITAL PRESS SWITCH FOR FLUIDS, PRESSURE SWITCH, ISE50-80, 845, 152 lb
[cm] -70No.PF-OMO0004CN-E PFMB7201-02 PFMB7201-N02 17 2x Rc1/4 NPT1/4 -71No.PF-OMO0004CN-E PFMB7201-02L PFMB7201-N02L 2x Rc1/4 NPT1/4 17 -72No.PF-OMO0004CN-E PFMB7201S-02 PFMB7201S-N02 2x Rc1/4 NPT1/4 -73No.PF-OMO0004CN-E PFMB7201S-02L PFMB7201S-N02L 2x Rc1/4 NPT1/4 17 -74No.PF-OMO0004CN-E PFMB7201-F02 21 2x G1/4 -75No.PF-OMO0004CN-E PFMB7201-F02L 2x G1/4 21 -76No.PF-OMO0004CN-E PFMB7201S-F02
A B PSE56-01 8.2 R1/8 PSE56-02 12 R1/4 PSE56-N01 9.2 NPT1/8 PSE56-N02 12.2 NPT1/4 PSE56-A2 PSE56-C01 Rc1/8 PSE56-A2 15.5 URJ1/4 PSE56-B2 9.5 TSJ1/4 PSE56-B2 Adapter with throttle ZS-31-X Model No.
ARX Series Specialty Regulators Regulator for 290psi (2MPa) ARX20, 21 Specifications ARX20 Model Piston regulator Regulator construction Relief type Relief mechanism NPT 1/8, 1/4 Piping port size NPT 1/8, 1/4 Pressure gauge port size 435 (3.0) Proof pressure psig (MPa) 290 (2.0) Maximum operating pressure psig (MPa) ARX20-N02 7~120 (0.05 to 0.85) Standard Regulating pressure range psig (MPa