Load Eccentricity 200 mm Graph n n Load Eccentricity 200 mm 10 10 1 Mass m (kg) Mass m (kg) 1 20 16 20 16 20 16 10 6 1 0.1 0.1 10 10 6 6 0.1 0.01 0.01 0 20 40 60 80 100 0 20 40 60 80 100 0 20 40 60 80 100 Overhang L (mm) Overhang L (mm) Overhang L (mm) Selection Example (Horizontal Mounting) 2.
The manifold no. shown below is for the L kits. For other kits the standard manifold can be used. Please contact for negative COM S kit. (Pitch) How to order negative COM valves VQ1130 N 5 C6 L = 12.5 x n + 10.5 L Dimension 1 2 3 4 5 6 7 8 9 10 23 35.5 48 60.5 73 85.5 98 110.5 123 135.5 No.
Clevis Dd9 L m l Knuckle CDP-2A 0.040 0.076 40 10 Polishing ball 10 46 3 38 3 X 18l 4 CDP-3A 0.050 0.093 40, 50, 63 50 12 Polishing ball 12 55.5 3 47.5 3 X 18l 4 CDP-4A 0.050 0.093 63 16 Polishing ball 16 71 4 61 4 X 25l 5 CDP-5A 0.050 0.093 80 18 Polishing ball 18 76.5 4 66.5 4 X 25l 5 CDP-6A 0.065 0.117 80 100 20 Polishing ball 20 83 4 73 4 X 30l 5 CDP-7A 0.065 0.117 100 25 Polishing
(except L and T1 kits) Note 3) Available only for F, L and T1 kits. Note 4) IP65 is available only for L, T and S kits. Note) In case of CM indicate on a specification sheet.
41.5 [48.5] (Pitch) P=10.5 13.5 M3 x 0.5 (A port) A A 13 10 (Pitch) P=10.5 11.5 M3 x 0.5 (A port) L plug connector (L) M plug connector (M) M8 connector (WO) Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 58.7 [60.9] 48.9 [51.1] 57.8 50.4 43.9 Refer to page 4-4-61 for dimensions with connector cable.
P+0.1 0.1 QCR = 2V x x 10 3 P 0.1 QCP = 2 x a x l x x 10 6 QC = QCR + QCP Formula Qc2 = Qc x n x Number of actuators x Reserve factor [l (ANR)] [l (ANR)] QCR = Air consumption of rotary table Qc2 = Compressor discharge flow rate [l /min(ANR)] n = Actuator reciprocations per minute QCP = Air consumption of tubing or piping V = Internal volume of rotary table [cm 3] Internal cross section of
Single wiring 5 6 7 8 9 10 19 20 19 20 19 20 19 20 19 20 19 20 19 20 19 20 1 2 3 4 5 6 7 8 9 10 1 2 3 4 NEW CONCEPT N.C. valve N.C. valve N.C. valve N.O. valve N.O. valve N.O. valve 5 6 7 8 9 10 1 2 3 4 R2 B R1 A P IP65 enclosure compliant kit (Lead wire) M 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 5 (R1) 3 (R2) 5 (R1) 3 (R2) 5 (R1) 3 (R2) 1 2 3 4 4 (A) 2 (B) 4 (A) 2 (B) 4 (A
[48.5] + 35.6 28.5 26.1 R1 P R2 R1 P R2 13 5 10 10 10 M5 x 0.8 (P, R1, R2 port) 17.5 14 28 L plug connector (L): SYJ3140-L-M5 M8 connector (WO): SYJ3140-WO-M5 M plug connector (M): SYJ3140-M-M5 Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 M8 x 1 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 64.3 [66.5] 54.5 [56.7] 63.4 56 49.5 R1 P R2 R1 P R2 R1 P R2 10 10 10 10 10 10 28 28 28 14
9 12 10 14 15.8 18.7 5.8 6.6 d L 15 17 22.2 7.6 M L M L 16 17 24.3 8.5 21 22 28 9.3 324 KFG2 Series Stainless Steel 316 Insert Fittings Applicable Tubing: Metric Size, Connection Thread: R, Rc Dimensions Bulkhead Union: KFG2E Applicable tubing size (mm) O.D.
Arm length L A Arm length L A Table 1 Table 1 A Model A Model CKZ3N50 CKZ3N63 CKZ3T50 CKZ3T63 5 10 Series CKZ3N Series CKZ3T 10 10 50 63 Arm length L: 150 mm Arm length L: 200 mm 3000 3000 Peak clamping force position 2500 2500 Peak clamping force position 0.7 MPa 2000 2000 Clamping force (N) Clamping force (N) 0.5 MPa 0.7 MPa 1500 1500 1000 1000 0.5 MPa 0.3 MPa 0.3 MPa 500 500 0 0 0 0.5
A A1 E1 L1 MM RR1 U1 ND NX NZ L 34 41 42 56 71 79 8.5 16 25 30 30 40 50 55 M8 x 1.25 10.3 11.5 34 41 42 56 71 79 8.5 10.5 14 18 21 21 16 20 22 28 38 44 25 30 30 40 50 55 M8 x 1.25 10.3 12.8 12 16 21 24 11.5 14 14 20 27 31 8 10 10 14 18 22 8 10 18 22 28 32 8 10 10 14 18 22 8 10 18 22 28 32 IY-G02 IY-G03 IY-G04 IY-G05 IY-G08 IY-G10 20 25 32, 40 50, 63 80 100 I-G02 I-G03 I-G04 I-G05 I-G08 I-G10
A p k v = 27.94.4@2 + l-013) . Ap 222. l@2 + r-013) .
. 26 Valve Drawings Series SYJ3000 2 Position Double (mm) 10 9 G H Grommet (G), (H) : SYJ3240-M5 5 10 Manual override 37 23.2 (Mounting holes) 22 2.5 B A 11 17.5 A B 14 77.2(GZ:79.2) [79.2] G : About 300 H : About 600 78.8(GZ:80.2) [82.2] (Lead wire length) (Non-locking) Manual override 41.5 [48] 33.5 29.1 22.5 R2 R1 P 13 5 10 10 28 5-M5 0.8 (Piping port) [ ] for AC L type plug connector
: Serial transmission L Kit: Lead wire F, L, M and P kits 1 to 12 stations M Kit: Multiple connector C8 (For 8) C10 (For 10) T kit 1 to 10 stations 4150 S kit (without unit) Solenoid weight is not included.
17 140 14.5 10 17 160 13 10 17 180 14 10 17 200 14.5 10 17 D-Z7/Z80 D-A3/A44/A5/A6 D-A59W D-Y59/Y69/Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL D-F5/J5/F5W/J59W D-F5BAL/F5NTL/F59F D-G39/K39 12 13 7 7.5 8 6 6 7 7 7 6 6 5 5.5 5 11 11 10 10 10 Since this is a guideline including hysteresis, not meant to be guaranteed.
pressure MPa 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 200 400 600 800 4000 6000 8000 2000 10 0 0 Flow rate L/min (ANR) Flow rate L/min (ANR) AC25 Rc 3/8 AC55 Rc 1 0.6 0.6 0.5 0.5 Outlet pressure MPa Outlet pressure MPa 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 500 1000 1500 4000 6000 8000 2000 10 0 0 Flow rate L/min (ANR) Flow rate L/min (ANR) AC30 Rc 3/8 AC60 Rc 1 0.6 0.6 0.5 0.5 Outlet pressure MPa
20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 Color: White 3.2 4 6 8 10 D VP VG VP DIN rail AXT100-DRS070 L As for , enter the number from the DIN rail dimensions table.
60 20 0.3 0.3 15 40 0.2 0.2 10 20 0.1 0.1 5 L L 0 20 30 50 60 Gripping point L (mm) 40 70 0 30 40 60 70 Gripping point L (mm) 50 80 90 12-10-4 4 Series MHY2/MHW2 180 Angular Style Air Gripper MHZ MHW2-32D MHW2-50D MHW2-20D MHF 300 25 100 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa MHL 250 20 0.6 80 0.6 Gripping force (N) Gripping force (N) Gripping force (N) 0.6 MHR 200 0.5 0.5 0.5
60 20 0.3 0.3 15 40 0.2 0.2 10 20 0.1 0.1 5 L L 0 20 30 50 60 Gripping point L (mm) 40 70 0 30 40 60 70 Gripping point L (mm) 50 80 90 12-10-4 4 Series MHY2/MHW2 180 Angular Style Air Gripper MHZ MHW2-32D MHW2-50D MHW2-20D MHF 300 25 100 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa MHL 250 20 0.6 80 0.6 Gripping force (N) Gripping force (N) Gripping force (N) 0.6 MHR 200 0.5 0.5 0.5