SMC Corporation of America
Elite Part Number Search
Search Results "NCDY2S32H-6000-A76H"

Switches D-A73.D-A73H D-A76H D-A72, D-A72H comact pror6ctiv6 iifrffi I co.'rua i Lishl 'ni'ng dr.d iFolec''v r-o'" . --{%!fi; ,Ek---

I}.A76H D.As3 D.A54 iuoft^n-fu0 o-iooil n"o^ @ R6ed sv ch Luminous diod . era*o-).

A79W,D-A33, 434, A33A, A34A, A44,A44tuD-A53, A54, 853, 854 3 Switch with indicator lamp (without A76H) 1) lf using less than a specified current, the light emitting diode goes to dark light or does not light, but operation ofthe switch is possible. 2) lftheswitches areconnected in series as shown in the following tigure, it makes vollage drop larger by the Inlernal resistance ofthe light

Pmleclion sl.wlulEC529 sps.lP67 waterprool (J|SC0920) oilprmf 'Suliix L lor lhs modelwilh a 3mlong lead wire 1 l Auto switch internal circuit Auto switch soecirications SefieS RSDO Beed switch D-A76H D"A73, DA73H o-472, D-472H Abck lJl ffi_ffi D-A80C D-A80, D-A8OH pnr*ir"y-'-' o cD-P11 I>A79W / two colors Indicator lamp opelins | | rdnse | | oFF Rd Green Fled .

Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy

Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m), Unit Specification: M (SI Unit Only), Calibration Certificate: A (Made to Order)

CY36 Consult with SMC in case a bracket with weight exceeding the above value is to be mounted. 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1000 2000 3000 4000 5000 6000 CY315 Note 1) According to the dead weight deflection in the figure on the right, provide clearance so that the cylinder does not touch the mounting surface or the load, etc., and is able

For Air (Orifice diameter: 10 mm, 15 mm, 20 mm, 25 mm) How to read the graph The sonic range pressure to generate a flow rate of 6000 L/min (ANR) is as follows.

)/For AFF75A to AFF220A AFF75A AFF125A AD402-03-2 G46-15-02 AFF150A AFF220A Applicable model Auto drain (2 pcs. each) Pressure gauge (2 pcs. each) Companion flange (2 pcs. each) Anchor bolt (3 pcs. each) AI-2S 2BJIS 10KFF 3BJIS 10KFF 4BJIS 10KFF Model AFF2B AFF4B AFF8B AFF11B AFF22B AFF37B AFF75B AFF75A AFF125A AFF150A AFF220A Model Note) Rated flow (l/min (ANR)) 300 750 1500 2200 3500 6000

AMD150 AMD250 AMD350 AMD450 AMD550 AMD650 AMD850 Model Note) 200 500 1000 2000 3500 6000 12000 Rated flow (l /min (ANR)) Port size (Nominal size B) 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 , , , , , , , , , , , Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note) Max. flow capacity at a pressure of 0.7 MPa. Max. flow varies depending on operating pressure.

AME150 AME250 AME350 AME450 AME550 AME650 AME850 Model Note) 200 500 1000 2000 3500 6000 12000 Rated flow (l/min (ANR)) Port size (Nominal size B) 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 , , , , , , , , , , , Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note) Max. flow capacity at a pressure of 0.7 MPa. Max. flow varies depending on operating pressure.

AMF250 AMF350 AMF450 AMF550 AMF650 AMF850 AMF150 Model Note) 500 1000 2000 3500 6000 12000 200 Rated flow (l/min (ANR)) Port size (Nominal size B) , , , , , , , , , 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 , , 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Weight (kg) Note) Max. flow capacity at a pressure of 0.7 MPa. Max. flow varies depending on operating pressure.

Model AMG150 AMG250 AMG350 AMG450 AMG550 AMG650 AMG850 Model Note) Rated flow (l /min (ANR)) 300 750 1500 2200 3500 6000 12000 Port size (Nominal size B) , , , , , , , , , , , 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note) Max. flow capacity at a pressure of 0.7 MPa. Max. flow varies depending on operating pressure.

AMH250 AMH350 AMH450 AMH550 AMH650 AMH850 AMH150 Model Note) 500 1000 2000 3500 6000 12000 200 Rated flow (l/min (ANR)) Port size (Nominal size B) 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 , , , , , , , , , , , 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Weight (kg) Note) Max. flow capacity at pressure of 0.7 MPa. It varies depending on operating pressure.

Fan motor Outlet thermometer Model Selection (Flow Capacity l/min (ANR)) HAA7 HAA15 HAA22 HAA37 Model Outlet side air (COOL AIR) 50C 70C 100C 1000 1500 700 2200 4000 1500 3300 6000 2200 5700 13000 Inlet air temperature 4300 Cooling side air Cooler Conditions: Outlet temperature 40C, Ambient temperature 32C, Air pressure 0.7 MPa Drain 14-15-1 2 Series HAA How to Order Precautions 15 10 D 1

HA Accessory (Option) AT HAW2 HAW7 HAW22 HAW37 HAW55 HAW75 HAW110 Applicable model Screw flange (With companion flange) HAWF-141 HAWF-142 HAWF-200 HAWF-200 ID Auto-drain AD402-04 AD600-06 AD600-10 AMG Model Selection (Flow Capacity l/min (ANR)) AFF HAW2-04 HAW7-06 HAW22-14 HAW37-14 HAW55-20 HAW75-20 HAW110-30 Model 1000 70C 100C 180C 50C 2000 6000 12000 15000 22000 30 Inlet air temperature

150 110, 120, 125, 150, 175, 200 20, 25, 32 10 to 100 225, 250, 275, 300 (CXWM16 to 25) 225, 250 (CXWM32) 225, 250, 275 (CXWL16 to 25) 225 (CXWL32) CXWM 16, 20, 25, 32 25 to 200 CXWL 16, 20, 25, 32 225, 250, 275 25 to 200 ML1 25, 32, 40 1001 to 2000 100 to 1000 CY3B 20, 25, 32, 40 2001 to 3000 100 to 1000 CY1B 50, 63 From 2001 200 to 2000 2001 to 4000 (25, 32) 2001 to 5000 (40) 2001 to 6000

Nominal size Pitch Compression Tension JB40-8-125 JB63-10-150 JB80-16-200 JB100-20-250 JB140-22-250 20, 25 32 40 50, 63 80 8 10 16 20 22 29 35.5 47.5 59 71.5 1.25 1.5 2 2.5 2.5 51 62.5 80.5 101 129 8.5 10 16 21 18 13 15 18 24 38 11 13 20 26 22 31 41 50 59.5 79 6 7.5 9.5 11.5 14 11 14 19 24 30 0.15 0.29 0.56 1.04 2.6 11 13.5 16 20 22 22 27 32 41 46 0.75 1 1.25 2 2.5 1300 3100 5000 7900 15300 6000

Series: NCDA1 (Standard w/ Magnet), Mounting: G (MF2, Rear Flange), Bore Size: 400 (4"), Stroke: 6000 (60"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.