SMC Corporation of America
Elite Part Number Search
Search Results "PF3W520S-03-1-A"

Note 1) 2 1/8, 1/4 3 3/8 4 1/2 Type Metric size Inch size 2 Elbow 3 Universal Tubing O.D. 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" Tubing O.D. 23 3.2 Note 2) 04 4 06 6 08 8 10 10 12 12 16 16 Control type 0 Meter-out 1 Meter-in * Meter-out and meter-in types can be visually identified by color of the knob.

ARM 2 2 3 3 3 4 4 5 5 6 6 2 2 2 3 3 4 4 5 5 6 6 1 2 1 2 3 1 2 1 2 1 2 A B C A B A B A B A B 6 x 4 4 x 3 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 19 x 16 12 x 10 25 x 22 19 x 16 1/4" x 5/32" 3/16" x 1/8" 1/8" x 0.086" 3/8" x 1/4" 1/4" x 5/32" 1/2" x 3/8" 3/8" x 1/4" 3/4" x 5/8" 1/2" x 3/8" 1" x 7/8" 3/4" x 5/8" SMC SMC SMC ARP P U Panel mount union Union IR-A IR SMC IRV : Basic size : With reducer

OUT2 41.8 40.3 NC 8 Load 4 Sensor 40 4.3 OUT1 Black Main circuit Main circuit 7 3 Load Brown 6 2 Blue + SMC FLOW SWITCH 5 1 12 to 24 VDC Series PF2A5 35.8 A 40 UNIT PF2A30-A RESET SET OUT2 NC 8 Load 4 Sensor OUT1 Panel fitting dimensions Black 3 x 7.2 (=21.6) 7 3 Load 8-M3 36 +0.5 0 6.4 Brown 6 2 + Blue 5 1 12 to 24 VDC 1 2 3 4 Series PF2A5 PF2A31-A 36 +0.5 0 19.4 Do not connect the white

1 Note 1) For the type with unit switching function [The type without the unit switching function will have a fixed SI unit (l/min, or l, m or m x 10).]

D-Y7WV D-Y7BAL D-A3 D-A44 D-G39 D-K39 D-A5 D-A6 D-A59W D-F5NTL D-F5LF D-P5DWL Bore size (mm) A A A A B A A A A B B B B B B B 32 12 11 7 4.5 0 0.5 3.5 4 0.5 9.5 8.5 4.5 2 1 1.5 0 40 12 11 7 4.5 0 0.5 3.5 4 0.5 9.5 8.5 4.5 2 1 1.5 0 50 12.5 11.5 7.5 5 0 1 4 4.5 1 10 9 5 2.5 1.5 2 0 63 12.5 11.5 7.5 5 0 1 4 4.5 1 10 9 5 2.5 1.5 2 0 80 15.5 14.5 10.5 8 2.5 4 7 7.5 4 14 13 9 6.5 5.5 6 2.5 100

They cannot be integrated into a unit. Conditions: Operating pressure 0.5MPa, Operating oil Turbine oil Class 1 (ISO VG32), Piping length 1m AS420-02, 03, 04 AS500-06 AS2000-01, 02 AS600-10 AS3000-02, 03 AS4000-02, 03, 04 Circuit 4.12-12

L O L G H F K J E D I A B C 2-4.5 A B C D E F G H I J K L Model 4 ZFC100-04 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 1/4" ZFC101-07 6 ZFC200-06 8 ZFC200-08 67 15.5 34 17.5 14 22 15.6 23.1 27 24 35 1/4" ZFC201-07 5/16" ZFC201-09 Element Replacement Element replacement procedure 1) Stop operation and reduce the filter's internal pressure to atmosphere. 2) Turn cover

to class B Rated coil voltage Allowable voltage fluctuation Note 2) VG Coil insulation type VP Note 1) With a light/surge voltage suppressor and power saving circuit, the light consumes a power equivalent to 2 mA.

AMH150 AMH250 AMH350 AMH450 AMH550 AMH650 AMH850 Air flow rate NOle) Q/min (ANR) 200 500 1000 2000 3500 6000 12000 1/4 3/8 1/2 3/8 1/2 3/4 1/2 3/4 1 3/41 1 1 1/2 1 1/2 2 Port size 1/8 1/4 3/8 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note) Max. ftow capacity at a pressure of O.7MPa{7.1 kgflcm').

O ring 4.5 X 2.5 X 1 O ring 6.4 X 5.2 X 0.6 O ring 5.5 X 3.5 X 1 O ring 7.4 X 5.8 X 0.8 O ring 6.5 X 4.5 X 1 O ring 11.4 X 9.4 X 1 Valve seal Gasket for valve retainer NBR NBR @7 @8 1.6-7 Series CG1 Basic/CG1BN: With Rubber Bumper (mm) Bore (mm) Standard stroke (mm) Long stroke (mm) TB ZZ GB GA F I MM E C AL H1 KA S D B1 NA A H J K P TA Up to 200 Up to 300 Up to 300 Up to 300 Up to 300 Up

(Part 1: General requirements) ISO 10218-1: Manipulating industrial robots Safety. etc. Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.

Dimensions Padlock mounting position (Port size) (Port size) Standard specifications Model P1 P2 A B C D E F G H VHS20 1/8, 1/4 1/8 71.5 23 40 37 28 42 17.5 40 VHS30 1/4, 3/8 1/4 87 32 53 49 38 53 20 53 VHS40 1/4, 3/8, 1/2 3/8 111 42.3 70 63 52 71 29 70 1 0 - Revision history Rev. A Safety Instructions (Piping) corrected.

Note 8) : For pipe thread type: NPT only 1069 A Air Filter 1021-AF-A Standard Specifications Model 10-/21-AF20-A 10-/21-AF30-A 10-/21-AF40-A 1 10-/21-AF60-A 10-/21-AF40-06-A 10-/21-AF50-A Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa 5 to 60C (No freezing) Ambient & fluid temperature 5 m Nominal filtration rating 1600

3/4 3/4, 1 1/8 1/8 1/8 1/8 1/8 M28 x 1 M38 x 1.5 M42 x 1.5 M42 x 1.5 26 29.4 37.3 37.3 43.3 Note) The dimension of C is the length when the filter regulator knob is unlocked. 1082 A

) 12 With filter (80 mesh) 23 15 , 8 1 4 1 48 (P, A, R port) 5-4-8

LC1-1-2000/Controller connector 2VA Note 1) 3VA Note 1) Caution Note 1) LC1-1B1V LC1-1B2V LC1-1B3V Contact P/A regarding a regenerative absorption unit which must be considered for these models depending on the operating conditions.

Model A side B side JIS Symbol A relay output module of devices up to 110 A B is available for control VAC, 3 A. 4(A) 2(B) A B N.C. valve N.C. valve 3(EB) SOL.b SOL.a 1 2 SV A00 5(EA) B side passage symbol: Green B side manual override: Green Tie-rod base manifold (For SV1000/2000/3000/4000) 1(P) 4(A) 2(B) A side coil A side spool valve B side spool valve N.O. valve N.O. valve 1 2 SV B00

HEAD OFFICE: 1-16-4, SHIMBASHI, MINATO-KU, TOKYO 105, JAPAN TELEPHONE: 03-3502-2740 FACSIMILE: 03-3508-2480

Description Assembly ARM2500 ARM3000 Body Aluminum die-casted Chromate treated/Platinum silver painted 1 Description No. Component Qty. Bonnet Common IN Individual IN Common IN Individual IN Polyacetal 2 Regulator Regulator ARM2500-A-02 ARM2500-B-02 ARM3000-A-03 ARM3000-B-03 9 1 Replacement Parts End plate R 10 1 Description Material Part no. End plate L 11 1 No.