<br>Note 2) Do not use combustible fluids, corrosive fluids, chemicals, poisonous gases, or seawater.<br>Note 3) Also, refer to the AP64 series check valve catalog, which can be found here. Be sure to check the precautions before considering this product.

<br>It removes oil mist contained in the exhaust and reduces exhaust noise of compressed air equipment at the same time.<br>Use this product when you want to both remove oil mist contained in the exhaust air from the solenoid valve and reduce the exhaust noise.<br><br>For selection, refer to the AMC series catalog, which can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=silencers-pressure-gauges&fa_id=10851

<br>Note) Production of the “-C1” type was terminated in October 2019; it has since converged with the “-C2” type.<br>G□ pressure gauge catalogs can be found here.

<br>The visibility of the pressure control range can be improved by color-coding the set pressure range (green) and the overall pressure range (red).<br>To set the color zones, remove the cover and adjust the red zone to highlight the set pressure range with the green zone.<br>The green zone setting range depends on the pressure range. Please refer to the catalog for details.

<br>Special order SMC self-align fittings (Model: “-X2” with electroless nickel plating) or commercially available self-align fittings made of stainless steel should be used. In addition, use an ozone-compatible product.<br>We recommend stainless steel for metal tubes and fluoropolymer for resin tubes.<br>However, as deterioration is unavoidable, be sure to replace them regularly.

<br>PFM5/7 series: Nitrogen, argon, and carbon dioxide <br>PF2A, PFMB, PFMC, and PFMV series: Nitrogen <br>Note 1) If argon is used with a flow switch other than one from the PFM5/7 series, errors in the measured values will occur. <br>Note 2) As helium has a low molecular weight, leakage will occur and errors in the measured values will occur.

<br>PF3W series: Ethylene glycol aqueous solution <br>Note) There are limitations regarding the viscosity, concentration, and temperature.<br>PF2D series: Pure water and liquids that do not corrode or permeate Teflon (Refer to the list of applicable fluids in the catalog.)

<br>PF2A, PF2W, and PF2D series: Straight piping with a length of at least 8 times the piping port size <br>LFE series: Straight piping with a length of at least 5 times the piping port size PFMB, PFMC, and PF3W704/720/740/504/520/540 series: Straight piping with a length of 8 cm or longer<br>PF3W711/511 series: Straight PVC piping with a length of 11 cm or longer<br>PF3W721/521 series: Straight

<br>This can be set by selecting the display unit reference when the flow switch is set. <br>Standard: Temperature 20℃, 1 atm (101.3 kPa), Relative humidity 65%<br>Reference: 0℃, 1 atm (101.3 kPa) <br>Note) Only the standard state can be displayed for PFMV series flow switches.

<br>The main changes include a wider variety of port sizes, the addition of a high-temperature specification, lower power consumption, and an improved IP rating. <br>Changes have also been made to the port position and appearance.

<br>Select a VNA series valve when the operating fluid is an inert gas and needs to flow in both directions (port 1 (A) to port 2 (B) and port 2 (B) to port 1 (A)) or when using an air-hydro circuit. <br>Select a VNB series valve when the operating fluid is an inert gas and 1-directional flow (A to B) is acceptable, when using water or oil as the fluid, or when using for low vacuum.

<br>② The manifold base is made of stainless steel. <br>③ The max. operating pressure differential or other solenoid specifications do not satisfy the customer’s operating conditions.

<br>However, the suck back valve on its own is only capable of changing the volume by moving the diaphragm up and down, so it cannot stop the fluid. <br>Therefore, a stop valve (2-way valve) is required on the inlet side of the suck back valve.<br><br>

<br>Since the diaphragm type process pump is not a metering pump, the discharge rate per cycle varies. <br>The “discharge amount A per cycle” is the value obtained by flowing a specified amount of liquid from each process pump and dividing the amount by the number of operation cycles.<br><br>

<br>For deionized water (pure water), replace all the water regularly because of the possibility of bacteria and algae generation inside the tank. <br>Take measures to prevent the generation of static electricity in the piping as well. <br>Refer to the “Specifications” section in the catalog for other applicable circulating fluids.

<br>Due to their Peltier type element, they are capable of both cooling and heating. <br>Note that HECR series thermo-cons can only be rack mounted. <br>Please refer to the catalog for details. <br>The HEC series catalog can be found here.

<br>Check that there is no leakage in the piping, including the customer’s device. If there is no leakage, supply circulating fluid according to section “3.5 Fill of circulating fluid” in the HRS series operation manual. <br>Depending on the problem, however, consider requesting maintenance from a maintenance company. <br>We can recommend service providers if needed.