Inch size 1/4" 1/8" 5/32" Flow rate (l/min(ANR)) 170 100 120 150 IN OUT Effective area (mm2) 2.6 1.5 1.8 2.3 IN P1 Note) Flow rate is the value measured under a pressure of 0.5 MPa and a temperature of 20C.
Normally Closed SERIES NVF 110 DIRECTIONAL AIR VALVE DIRECT SOLENOID OPERATED CHARACTEFISTICS Port Sizss (NPTO '10-32 P&E; 10-32 or 1/8"A Opelating Prsssure 0'100 PSI; 0-150 PSI (H) ftoof Pre6sur 225 PSIG (15Kgflcm'z) Operailng Temperature 14-140'F(101o + 6O"C) a;a lnrusn s.6 VA (50 Hz),5.0 VA(60 Hz) Holding 3.4 VA (50 Hz),2.3 VA (60 Hz) PowerConaumptlon DC 1 . 8 W c, 0.055 , 0.05 (H Type
Positioning operation method of operation . 110 -2- 8.1 Point table method . 112 8.1.1 Positioning operation indication of the point table method (Example) . 112 8.2 Remote register method . 116 8.2.1 Positioning operation indication of the remote register method (Example) . 116 9.
: 0.4 MPa Supply pressure: 0.4 MPa 100 90 100 90 ZQ Vacuum pressure (kPa) Vacuum pressure (kPa) 80 80 70 70 ZF 60 60 50 50 ZP 40 40 30 30 ZCU 20 20 10 10 AMJ 0 0 10 20 30 40 50 60 70 80 90 100 110 120 20 60 100 140 180 220 260 300 130 Suction flow rate (/min(ANR)) Suction flow rate (/min(ANR)) Misc.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4.5 mm Coil: Class B, Class H 6 mm 8 mm Rated Voltage 100 VAC, 200 VAC, 110 VAC, 220 VAC, 240 VAC, 230 VAC, 48 VAC, 24 VDC, 12 VDC 10 mm 1 2 1 4 3 8 , 1 2 Port size 1 8 1 4 , 1 4 3 8 , Normally Open (N.O.)
= 4, 8, 12, 16 ) Note 2) 110 + 55 (n 4) 2 (n = 4, 8, 12, 16 ) Note 2) 120 + 55 (n 4) 2 (n = 4, 8, 12, 16 ) Note 2) 20 + 55 (n 2) 2 (n 4) 2 D-A59W n (Same surface) 1 100 110 120 15 90 2 (Different surfaces, Same surface) 1 120 130 140 25 110 D-F5NT (n = 2, 4, 6, 8 ) Note 1) 110 + 55 (n = 4, 8, 12, 16 ) Note 2) 120 + 55 (n 4) 2 (n = 4, 8, 12, 16 ) Note 2) 140 + 55 (n 4) 2 (n = 4, 8,
VAC 100 VN SY100-82-2-01 200 VAC 200 VN SY100-82-2-02 110 VAC (115 VAC) 110 VN SY100-82-2-03 220 VAC (230 VAC) 220 VN SY100-82-2-04 When making connections, please note that using other than the supported size (3.5 to 7) heavy-duty cord will not satisfy IP65 (enclosure) standards.
JSX21U Series b JSX31 Series 9 mm shorter (12% reduction) JSX31 Series Height Applied voltage 0 V Inrush power Standard model 69 mm 78 mm Power saving type Holding power 0 W 200 ms JSX21U Series Effective after being energized for more than 200 ms 110 g lighter (24% reduction) Weight Power Consumption (Holding) [W] Height [mm] Weight [g] Size 10 Size 20 Size 30 JSXmmU Series 2 3 3 JSX21U
(Example) SYJ3120-5M-M3 VJ3000-13-1 -+ Single Double Rated voltage 5 port DC AC (50/60 Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, DC voltage is only available.
(Example) SYJ3120-5M-M3 VJ3000-13-1 -+ Single Double Rated voltage 5 port DC AC (50/60 Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, DC voltage is only available.
For sub-plate style, mainfold type 40, 41, 41R, 42, 42R Port size E: Push-turn locking lever type 02: 1/4 port With sub-plate 01: 1/8 port With sub-plate Nil: Without sub-plate Body option Nil: Individual pilot exhaust style (With gasket and screws) Electrical entry Grommet L plug connector 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 24, 12 VDC/ 100, 110, 200, 220 VAC M plug connector DIN
150 150 2759 200 200 2760 250 200 2760 325 325 2761 400 325 2761 Stroke (In Inches and Hundredths of Inches) Bore 150 200 250 325 400 Note: Quantity is one piece.
45 150 to 700 26 M10 X 1.25 32 6 8 46.5 5.5 22 19.5 17 12 13 11 45 150 to 1000 26 M14 X 1.5 40 8 10 56.2 7 24 21 22 14 16 12.5 50 200 to1000 32 20, 25 NA S TD TT TX TY TZ Z ZZ NN P N Bore size Stroke range 1 8 30 20 M20 X 1.5 146 8 10 32 32 52 192 202 150 to 700 20 1 8 34.5 M26 X 1.5 25 146 9 10 40 40 60 196 206 150 to 700 20 1 8 42.5 M26 X 1.5 32 159 9 10 40 40 60 209 219 150 to 1000 22
10, 20, 30, 40, 50,7 5, 100, 125, 150 *90and 91-series MXQ6 products do not have shock absorbers.
Operating pressure Proof pressure Burst pressure Ambient and operating temperature Cv Vacuum to 250 psig (1.7 MPa) Vacuum to 125 psig (0.9 MPa) 1000 psig (6.9 MPa) 8000 psig (55.2 MPa) 14 to 160F (10 to 71C) (No freezing) 1) 0.29 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 2) 4 x 10-9 Pam3/sec 2) Ra max 15 in. (0.4 m) Option: 10 in. (0.25 m), 7 in. (0.18 m), 5 in. (0.13 m) Face seal, Tube weld 70 to 110
Seal Metal seal Rubber seal Coil voltage 0 1 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Function 1 2 3 Stations U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) D side (2) Note 1) Applicable to DC specifications. Note 2) Refer to page 2-5-39 for external pilot specification.
Nil E Yes Without light, with surge voltage suppressor Seal Metal seal Rubber seal 0 1 Coil voltage Function 1 2 3 Stations 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC D side U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) (2) Applicable to DC sepecifications.
It is already built-in to the rectifier circuit. 2 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 3 Electrical entry 4 220 VAC 50/60 Hz [230 VAC 50/60 Hz] D With connector DIN terminal DO Without connector DC specifications of type D and DO is only available with 12 and 24 VDC. Power saving circuit is not available in the case of D or DO type.
light Diode (varistor when non-polar types) LED In common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
VN Solenoid valve option Nil Standard Rated voltage 1 2 3 4 5 6 7 8 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-9 by Applicable Fluids Check List for special fluids outside of the standard.