DC specifications of type "D" and "DO" is only available with 12 and 24 V DC.
It is already built into the rectifier circuit. 2 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 3 4 220 VAC 50/60 Hz [230 VAC 50/60 Hz] Electrical entry D With connector DIN terminal (Type D) DC specifications of type D and DO are only available with 12 and 24 VDC. Power saving circuit is not available for D or DO types.
D-G5P D-K59 D-5NTL D-H7A1 D-H7A2 D-H7B D-H7C D-G59W D-G5PW D-K59W D-G59F D-G79 D-H7PW D-H7BAL D-H7LF D-H7NF D-G5BAL D-H7PW D-H7BW 24VDC 110VAC 220VAC 24VDC 24VDC 110VAC 220VAC 24VDC 110VAC Yes/2 Wire D-B54 Yes/2 Wire D-B53 No/2 Wire D-B64 D-B73 D-C73 D-C73C D-B76 D-C76 D-B80 D-C80 D-C80C Yes/2 Wire Yes/2 Wire 20mA 4~8VDC 50mA 40mA 20mA 24V 48V 110V No/2 Wire ACCESSORIES SWITCH BANDS FOR
Applicable fitting size Noise reduction (dB) Effective area (mm2) (Cv factor) Series Model A L D d D VQC2000 10 AN20-C10 36.5 57.5 30 16.5 30 Elbow fitting assembly VVQ2000-F-L(C4/C6/C8/N3/N7/N9) It is used for piping that extends upward or downward from the manifold.
SI Unit: 0 (w/o SI Unit), Stations: 12 Stations, SUP/EXH Block Mounting: B (Both Sides 2~16 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
Stations: 12 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 1 (Connector Top Direction), Stations: 12 Stations, SUP/EXH Block Mounting: B (Both Sides 2~16 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 2 (Connector Side Direction), Stations: 12 Stations, SUP/EXH Block Mounting: B (Both Sides 2~16 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
Stations: 12 Stations, SUP/EXH Block Mounting: Both Sides 2~20 Stations, Pilot: Internal Pilot, A, B Port: 1/4" One-touch Fitting, Mounting Method: DIN Rail Mounting
SI Unit: DeviceNet, PROFIBUS-DP, EtherNet/IP, Stations: 12 Stations, SUP/EXH Block Mounting: Both Sides 2~16 Stations, Pilot: Internal Pilot, A, B Port: 1/4" One-touch Fitting, Mounting Method: DIN Rail Mounting
SI Unit: w/o SI Unit, Stations: 12 Stations, SUP/EXH Block Mounting: Both Sides 2~16 Stations, Pilot: Internal Pilot, A, B Port: 1/4" One-touch Fitting, Mounting Method: DIN Rail Mounting
Enclosure: IP67, SI Unit: EtherNet/IPâ„¢ - 32 Outputs - Connector M12, SI Unit Output Polarity: -COM, Stations: 12 Stations, P, E Port Entry: Both Sides 2~16 Stations, SUP/EXH Block Assembly: Internal Pilot, A, B Port: 1/4" One-touch Fitting, Mounting: DIN Rail Mounting, DIN Rail Option: -
Enclosure: IP67, SI Unit: EtherNet/IPâ„¢ - 32 Outputs - Connector M12, SI Unit Output Polarity: +COM, Stations: 12 Stations, P, E Port Entry: Both Sides 2~16 Stations, SUP/EXH Block Assembly: Internal Pilot, A, B Port: 1/4" One-touch Fitting, Mounting: DIN Rail Mounting, DIN Rail Option: -
Enclosure: IP67, SI Unit: EtherCAT - 32 Outputs - Connector M12, SI Unit Output Polarity: -COM, Stations: 12 Stations, P, E Port Entry: Both Sides 2~16 Stations, SUP/EXH Block Assembly: Internal Pilot, A, B Port: 1/4" One-touch Fitting, Mounting: DIN Rail Mounting, DIN Rail Option: -
SI Unit: DeviceNet, PROFIBUS-DP, EtherNet/IP, Stations: 12 Stations, SUP/EXH Block Mounting: Both Sides 2~16 Stations, Pilot: Internal Pilot, A, B Port: 1/4" One-touch Fitting, Mounting Method: DIN Rail Mounting
Type: Base for Manifolds, Communication Protocol: EtherNet / IP Compatible, Output Format: PNP Sensor Input, Type: EX250 Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: -, Connector: N/A, Mounting Method: DIN rail mounting (with DIN rail), Port pipe connection port diameter: ø1/4" single-action pipe fitting (A-, B-Port) / ø5/16" single-action pipe fitting (P-, E-Port
Type: Base for Manifolds, Communication Protocol: N/A, Output Format: -, Type: EX500, 128 Points Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: -, Connector: N/A, Mounting Method: DIN rail mounting (with DIN rail), Port pipe connection port diameter: ø1/4" single-action pipe fitting (A-, B-Port) / ø5/16" single-action pipe fitting (P-, E-Port), Specification
Type: Base for Manifolds, Communication Protocol: N/A, Output Format: -, Type: Multi-Connector Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: -, Connector: N/A, Mounting Method: DIN rail mounting (with DIN rail), Port pipe connection port diameter: ø1/4" single-action pipe fitting (A-, B-Port) / ø3/8" single-action pipe fitting (P-, E-Port), Specification: Internal
Type: Base for Manifolds, Communication Protocol: EtherNet / IP Compatible, Output Format: PNP Sensor Input, Type: EX250 Compatible Tie-Rod Base Manifold, Number of Inputs/Outputs: -, Connector: N/A, Mounting Method: DIN rail mounting (with DIN rail), Port pipe connection port diameter: ø1/4" single-action pipe fitting (A-, B-Port) / ø3/8" single-action pipe fitting (P-, E-Port