SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-S31-17-M3"

Withstand voltage -13No.PF-OMA1011-A Mounting and Installation Installation Mounting by panel mount adapter Fix the panel mount adapter to the Controller with the set screws M3 x 8L (2 pcs.) as attached.

Fittings & Tubing Air Cylinders Rotary Actuators 11-/22-MXP6-5 W AA H 7 4 depth 2.5 2.5 11.2 2.3 3.5 1 3 4 x M3 x 0.5 depth 3 +0.030 0 D B 0.05 9.5 1 3.5 20 14 13 18 C 6 +0.030 0 depth 2.5 2.5 Width across flats 6 E 5 6 5 Prepared hole diameter 3.3 2 x M4 x 0.7 Piping port 2 x M3 x 0.5 (Plug: M-3P) F QL 6 13.5 17 Stroke: S M 2 0.05 M4 x 0.7 Mounting base side B D 7 5 2 x M3 x 0.5 Piping

M3 female -M3 male M-3UL For soft nylon tube. Barb elbow P. 92 3.18/2.18 Body rotates at 360 around the stud axis. Nipple M-5ALU-3 Fitting to workpiece and fitting to fitting connection. P. 90 For polyurethane tube. 3.18/2 M3 Universal tee M5 male -M5 male M-5N Body rotates at 360 around the stud axis. M3 female -M3 female -M3 male For soft nylon and polyurethane tube.

x 0.5 (Plug: M-3P) F 6 QL 13.5 17 0.05 Stroke: S M 2 M4 x 0.7 Mounting base side B D 7 5 2-M3 x 0.5 Piping port Y J 3 M3 x 0.5 Vacuum suction port Z Max. 9.5 (Rubber stopper) 2.4 depth 2 2.5 3.5 +0.030 0 7 +0.030 0 depth 2 2.5 Q QL Without magnet and switch rail 2 2-M2 x 0.4 depth 2.2 12 Metal stopper 11-/22-MXP6-10 Max. 10.5 F 4-M3 x 0.5 depth 3 12 2-M2 x 0.4 depth 3 (mm) E F H J M Q QL

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 60

Pressure Control Equipment O-ring Cross recessed round head screws (with SW) (M3) End block Tie-rod For common supply blocks, reversible and double-sided mounting is available. Common supply tie-rod Industrial Filters Cross recessed round head screws (with SW) (M3) Tightening torque: 0.32 0.03 Nm 451 Series ARM5A/5B/5S Replacement Procedure of Diaphragm 4 4.

Reed switch D-X 20Data 10-13-17

9 @0 Seal kit NBR MHY10-PS MHY16-PS MHY20-PS MHY25-PS 2.8-10 180 Angular Gripper Series MHY2 Dimensions MHY2-10D Pin hole positioning 30 9 9 2-M3 X 0.5 Depth 4 (Mounting thread) 4 4-M3 X 0.5 3H9 +0.025 0 Depth 3 (Thread for mounting attachment) 6 0.005 0.025 4 4-M3 X 0.5 Depth 6 (Mounting thread) 3 6 2 3.4 2M3 X 0.5, 6 deep 12 (Mounting hole) (Mounting thread) (Limited area for mounting attachment

Note 2) When the compressor oil mist discharge concentration is 30mg/m3 (ANR). Note 3) Bowl O-ring and other O-rings are slightly lubricated. Note 4) When the outlet pressure is 0.5MPa. (The rated flow varies depending on the set pressure.) Keep the air flow within the rated flow to prevent an outflow of lubricant to the outlet side.

Pressure Control Equipment O-ring Cross recessed round head screws (with SW) (M3) End block Tie-rod For common supply blocks, reversible and double-sided mounting is available. Common supply tie-rod Industrial Filters Cross recessed round head screws (with SW) (M3) Tightening torque: 0.32 0.03 Nm 451 Series ARM5A/5B/5S Replacement Procedure of Diaphragm 4 4.

A (+) () () (+) 17 17 Station 9 Station 9 SOL. B SOL. B (+) () () (+) 18 18 SOL. A (+) () 19 COM (+) () 19 Station 10 SOL. B (+) () 20 COM (+) () 20 SOL. A (+) () 21 Negative COM. spec. Positive COM. spec. Station 11 SOL. B (+) () 22 SOL. A (+) () 23 Station 12 SOL. B (+) () 24 COM () (+) 25 Special Wiring Specifications (Option) COM () (+) 26 Positive COM. spec. Negative COM. spec.

W: 13 [kW] W Efficiency Power supply output VI: 20 [kVA] Q = P = Q = P = V x I x Power factor In this example, using an efficiency of 0.7: In this example, using a power factor of 0.85: 13 0.7 = = 18.6 [kW] = 20 [kVA] x 0.85 = 17 [kW] Cooling capacity = Considering a safety factor of 20%, Cooling capacity = Considering a safety factor of 20%, 18.6 [kW] x 1.2 = 22.3 [kW] 17 [kW] x 1.2 = 20.4

Refer to pages 17 through 19 for general safety instructions and common precautions, and to pages 20 through 22 for specific product precautions.

bolt) and M4 x 0.7 (Hexagon nut) M3 x 0.5 x 10 L (Hexagon socket head cap screw) 2 x M4 x 0.7 through Steel ball Steel ball (14+ST) (16) 4 2 x M3 x 0.5 through 6 (mm) ST 10 20 30 40 50 14+ST 24 34 44 54 64 17+ST 27 37 47 57 67 49.5+ST 59.5 69.5 79.5 89.5 99.5 61+ST 71 81 91 101 111 Part no.

Note: 1g = 0.0353oz Options Body options/End boss type Single acting type, normally closed Symbol Piping port position Applicable model Double acting Type of piping port MHZA2-6/MHZAJ2-6 M3 x 0.5 M3 x 0.5 With 4 One-touch fitting With 4 hose nipple M3 x 0.5 Single acting Standard Side ported Nil E K H M Axial port 2 Series MHZA2-6/MHZAJ2-6 Parallel Type/Compact Series Construction/Standard

34 18.5 12.6 9.2 35 4.5 7.5 29h9 29.5h9 14H9 5.3 2.5 4.2 10 3.3 6 3.5 2.2 5.3 4 M5 x 0.8 M4 x 0.7 3 5.5 38 23 15.5 10.5 40 4.5 9.5 33h9 34 h9 17H9 5.3 2.5 4.2 10 4.2 7.5 4.5 2.5 6 4 M5 x 0.8 M5 x 0.8 7 5.5 45 30 18.4 12.2 50 5 7 39h9 40 h9 20H9 6.5 2.5 4.5 11.5 4.2 7.5 4.5 2.5 6 5 (mm) JJ M3 x 0.5 M3 x 0.5 M3 x 0.5 M4 x 0.7 JK JU M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1 P M3 x 0.5 M3 x 0.5 M3 x

20.5 16.2 12 14 8 6 14 5 17 6.5 18 5.5 22 10 28.8 19 21.5 18.8 14 17 17 7.5 25 6.5 22 17 7 30 8 22 12 30.3 22 23.5 19.3 17 19 17 9 8 38 22 Reference dimensions after R(PT) thread installation. 100

The intersection H is the amount of moisture included in the compressed air 1 m3 at 102 psi (0.7 MPa), and a pressure dew point 77F (25C). The amount of moisture is 3.0 g/m3. 10.

8 10 10 0 L/min (ANR) ISO Class 7 ISO Class 7 10 10 Particle concentration [particles/m3] Particle concentration [particles/m3] ISO Class 6 ISO Class 6 10 10 0 L/min (ANR) 50 L/min (ANR) ISO Class 5 10 10 ISO Class 5 30 L/min (ANR) 1000 1000 ISO Class 4 ISO Class 4 90 L/min (ANR) 100 100 50 L/min (ANR) 10 10 1 1 0 0.1 0.2 0.3 0.4 0.5 0.6 0 0.1 0.2 0.3 0.4 0.5 0.6 Particle diameter [m] Particle