1.5 43.5 Standard type mm Stroke range (mm) Bore size (mm) 63 80 100 A B C D E F H I J K L M N OB P 63 55 15 20 77 31 M10 x 1.5 103 7 17 8 60 9 14 Rc 1/4 30 to 100 73.5 63.5 21 25 98 35.5 M16 x 2.0 132 6 22 10 77 11 17.5 Rc 3/8 40 to 100 88 76 27 30 117 40 M20 x 2.5 156 6.5 27 12 94 11 17.5 Rc 3/8 40 to 100 mm Q RB S U Z Bore size (mm) 63 80 100 34 10.5 93 47.5 19 39 13.5 112.5 57.5 26 43

NTJ-015A NT-02 NT-04 NT-05 12 7.8 M5 x 0.8 9.2 8 4 H B 20 12.5 15.0 13 5 M8 x 1.25 32, 40 21.0 25.4 22 8 M14 x 1.5 50, 63 26 31.2 27 11 M18 x 1.5 Electrical Wiring Output type The output signal of the stroke reading cylinder is A/B phase difference output (open collector output) as shown in the figure below.

35.5 M26 x 1.5 43.5 Basic Style Stroke range (mm) Bore size (mm) 63 80 100 A B C D E F H I J K L M N OB P 63 55 15 20 77 31 M10 x 1.5 103 7 17 8 60 9 14 Rc 1/4 30 to 100 73.5 63.5 21 25 98 35.5 M16 x 2.0 132 6 22 10 77 11 17.5 Rc 3/8 40 to 100 88 76 27 30 117 40 M20 x 2.5 156 6.5 27 12 94 11 17.5 Rc 3/8 40 to 100 Q RB S U Z Bore size (mm) 63 80 100 34 10.5 93 47.5 19 39 13.5 112.5 57.5 26 43

Symbol 2 3 4 Metric sizes 04 06 08 10 12 4 x 3 6 x 4 8 x 6 10 x 8 12 x 10 Symbol B A Inch sizes Basic size With reducer 03 05 07 11 13 1/8" x 0.086" 3/16" x 1/8" 1/4" x 5/32" 3/8" x 1/4" 1/2" x 3/8" Note 1) Applicable fittings: LQ2 Note 2) For details of the applicable tubing sizes, refer to page 945.

Metric size*1 Inch size*1 Type 02 2*3 23 3.2*2 04 4 06 6 01 1/8" 03 5/32" 2 Elbow Control type*1 0 Meter-out 1 Meter-in *1 Metric size: Light gray Inch size: Orange *1 Meter-out and meter-in types can be visually identified by the color of the knob. Meter-out: Gray Meter-in: Light blue *2 Use 1/8" tubing. *3 Only polyurethane tubing is applicable for 2.

Example) AR30K-03BE-1NR-B w e V q Body size 20 25 30 40 50 60 Symbol Description V w With backflow function Nil Without backflow function K Note 1) With backflow function + V e Pipe thread type Nil Rc N NPT F G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 V r Port size + a Mounting Nil Without mounting option B Note 3) With bracket H With set nut (for panel mount) + Nil Without pressure

Pressure gauge port size Port size Model AR425/435 AR625/635 AR825/835 AR925/935 1/4, 3/8, 1/2 3/4, 1 1 , 1 2 80 98 126 160 145.5 155 216 241 3 7 5 10 1/4 1/4 1/4 1/4 39.5 43 75 90 50.0 85 48 52 80 90 B24P B25P 67 78 110 140 73 78.5 94.5 4 1 2 1 109.5 680

B H NTJ-015A NT-02 NT-04 NT-05 M5 x 0.8 7.8 9.2 12 8 4 H B M8 x 1.25 12.5 15.0 20 13 5 M14 x 1.5 21.0 25.4 32, 40 22 8 M18 x 1.5 26 31.2 50, 63 27 11 Electrical Wiring Input/Output The input/output of the scale cylinder is performed by a 7 shielded twisted pair wire from the sensor section plus a connector.

NTJ-015A NT-02 NT-04 NT-05 12 M5 X 0.8 4 8 9.2 7.8 H B 20 M8 X 1.25 5 13 15.0 12.5 32, 40 M14 X 1.5 8 22 25.4 21.0 50, 63 M18 X 1.5 11 27 31.2 26 Electrical Wiring Output style Input/Output The output signal of the stroke reading cylinder is A/B phase difference output (open collector output) as shown in the figure below.

D C d H B 32 40 50, 63 80 100 16.5 21 26 31 39 19.6 25.4 31.2 37.0 47.3 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 6 8 11 13 16 17 22 27 32 41 NT-03 NT-04 NT-05 NT-08 NT-10 Piston rod ball joint KJ (DIN 648) Zinc chromate plated steel Bore d3 Order No. d1 h d6 b3 b1 l d7 l3 sw 32 M10x1.25 KJ10D 10 43 28 10.5 14 20 19 13 14 17 40 M12x1.25 KJ12D 12 50 32 12 16 22 22 13 16 19 50/63

T 4.41 lbs. (2 Ko) P T 0.06 in. (1.5 mm) o.T o.oE in (2.o mm) T.T. 0.14 in. (3.5 mm) '75 PSIG (5 Kgf/cm2) A B D E F a H b u 5 (153.7) 4.87 (123 7l 1.57 (40) 1 . 1 8 {30t ).87 t22l u.4i, ( 1 1 ) J.75 (i 9) ).12 (3) ).43 :1 1) Millimeters in Parenlheses r.u.F, 4.41 rbs {2 Ko} t ' l 0.06 in. (1 5 mm) O T 0 08 in. (2 0 mm) 0.14 4n. (3.5 mm) .75 PSIG (5 Kgl/cm2) A B C D E F G H o , t ( (1s6 7)

size: 50, 63, 80, 100 Applicable related components Total stroke time s Tubing Speed controller Solenoid valve Silencer 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 400 MB 50 10% 30% 70% 300 50% Stroke mm AS2201F -02-10 200 100 50% 30% 10% 70% 0 400 MB 63 300 Stroke mm AS3201F -03-10 200 100 0 ANA1 -C12 T1075 400 MB 80 300 Stroke mm AS4000-03 200 100 0 400 MB 100 300 Stroke mm 200 AS4000-04

24 327 IDF4E / IDF6E / IDF8E / IDF11E ( 10 :0.8m) [ AC100V ] [ AC200V ] (:1.9m) [ AC200V ] (17) mm A B C D E F G H J K L M N P Q IDF4E Rc1/2 453 13 498 568 31 42 283 355 80 230 32 15 284 15 240 80 275 IDF6E Rc3/4 455 270 485 IDF8E Rc3/4 300 IDF11E Rc3/4 IDF Series 6-3 6 3 IDX-OM-W011 6 IDF15E1 mm 603 41 54 300 16 C R 1 C R 1 87 578 [AC200V] [AC200V] 396 0.8m (10, (:10, :0.8m) 43

2.8 (ANR) 1) 60Hz 3.1 m 3/min 50Hz 2.9 2) 60Hz 3.2 MPa 0.7 35 32 10 () AC100V(50Hz) AC100,110V(60Hz) 3) AC200V(50Hz) AC200,220V(60Hz) 3) (50/60Hz) W 420/480 (50/60Hz) A 4.3/4.6 3.4/3.1 4 ) A 10 R134a(HFC) () Rc1 kg 46 1 2 () kW 15 1(ANR)[2065%] 2[32] 3() 430mA 6 1 6. 6.2 IDF15E1 mm 603 41 54 300 16 C R 1 C R 1 87 578 [AC200V] [AC200V] 396 0.8m (10, (:10, :0.8m) 43

IDF60/70/80/90 Series 6.2 Reset the Thermal relay and High Pressure Switch 6-3 IDX-OM-Y002 Chapter 6 Troubleshooting 6.2 Reset the Thermal relay and High Pressure Switch IDF190D/240D Series 6-4 IDX-OM-Y002 Chapter 7 Documents Chapter 7 Documents 7.1 Specifications Models Item IDF190D-3-W IDF240D-3-W Standard condition (ANR) Note 1) 50Hz 32 43 60Hz 38 50 Air flow capacity m3/ min Compressor

2) IDU Series 7-1 71 IDX-OM-W023 8 K 8 K 8-1 ( ) 8-2 1.6Mpa AD48-8-A-X2112 10 KQ2H10-02AS IDU8E/11E/15E1-*-K N.O. () 0.151.6MPa IDU Series 8-1 8 1 IDX-OM-W023 8 K IDF-S1926 () 1 AD48-8-A-X2112 1 1) 2019 3 2019 2 SERIAL No.XP AD48-8-X2110 IDF-S0086() SMC WEB IDF-S0002 1 C42FP-260S 1 IDF-S0529 1 IDU Series 8-2 8 2 IDX-OM-W023 9 L 9 L 9-1 ( ) 9-2 1.6MPaADH4000-04

Supersonic cleaning Drying Double-packing Sensor Clean room class 1000 Shipment 381 For Deionized Water and Chemical Liquids Digital Flow Switch PF2D Series RoHS How to Order Remote Type Sensor Unit PF2D5 13 20 1 C Flow rate range Option (Refer to page 391.) 04 20 40 None e-con connector x 1 pc.

Item CH2 measured value: 16-bit signed integer Bit offset 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 Item CH32 measured value: 16-bit signed integer Bit offset 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 Item CH4 measured value: 16-bit signed integer Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Error diagnosis CH4 diagnosis CH3 diagnosis CH2 diagnosis CH1 diagnosis Reservation

Without nozzle KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 VMG1-R02-300 VMG1-R02-350 VMG1-R02-400 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 01 02 03 04 05 06 07 11 12 13 21 22 23 24 1 1.5 2 2.5 3 3.5 4 1 1.5 2 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 Connection size Piping connection method Symbol Size and model no.

capacity (cm3)Weight (kg)AFD401/43/81/2Air1.5 MPa1.0 MPa0.05 MPa?