Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 1 Output+Analog Voltage, Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certificate: -

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 1 Output+Analog Voltage, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: -, Adapter: -, Calibration Certificate: -

Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: NPN Open Collector 2 Outputs, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: No Lead Wire, Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)], Calibration Certificate: -

USEr Pressure gauge measurement value (PD) 0 to 4000 -200 to 4200 -78No.PS-OMW0012-C Relationship between the measurement value (PD) and pressure value (Range: -101 kPa, Unit: kPa) -79No.PS-OMW0012-C Conversion formula of the process data and pressure gauge measurement value (1) Conversion formula from the process data to the pressure gauge measurement value: Pr = a (PD) + b (2) Conversion

Move on to PD Accumulated SW1 bit check. PD Accumulated SW1 bit check Select the accumulated SW1 bit check by pressing the UP or DOWN button. : This function is available with IO-Link communication. Move on to PD Accumulated SW2 bit check.

Relationship between flow rate and PD -78No.PF-OMZ0002-A Conversion formula of the process data and flow measurement value (1) Conversion formula from the process data to the flow measurement value: Pr = a (PD) + b (2) Conversion formula from the flow measurement value to the process data: (PD) = (Pr b) / a Pr: Flow measurement value and pressure set value PD: Flow measurement value (process

0.00 to 3.70 PD 0 to 1000 0 to 1050 Flow L/min 0 to 200 0 to 210 200 L Flow gal/min 0.0 to 7.1 0. to 7.4 PD 0 to 1000 0 to 1050 Flow L/min 0 to 500 0 to 525 500 L Flow gal/min 0.0 to 17.6 0. to 18.6 PD 0 to 1000 0 to 1050 Flow L/min 0.40 to 4.00 0.25 to 4.50 4 L Flow gal/min 0.11 to 1.06 0.07 to 1.19 PD 100 to 1000 63 to 1125 Flow L/min 1.8 to 20.0 1.3 to 21.0 PF2D5 20L Flow gal/min 0.45

Relationship between flow rate and PD -74No.PF-OMY0002 Conversion formula of the process data and flow measurement value (1) Conversion formula from the process data to the flow measurement value: Pr = a (PD) + b (2) Conversion formula from the flow measurement value to the process data: (PD) = (Pr b) / a Pr: Flow measurement value and pressure set value PD: Flow measurement value (process

L+ power supply C/Q signal P24 power supply Enable Diagnostics is generated. 3 Short Circuit Monitor Unit Disable Diagnostics is not generated. All outputs are turned OFF while maintaining the process data output valid. Clear/ PD Out valid Set the IO-Link communication process data output when the EtherNet/IP communication error is occurred.

L+ power supply C/Q signal P24 power supply Enable Diagnostics is generated. 3 Short Circuit Monitor Unit Disable Diagnostics is not generated. All outputs are turned OFF while maintaining the process data output valid. Clear/ PD Out valid Set the IO-Link communication process data output when the EtherNet/IP communication error is occurred.

The operating fluid temperature should be -5 to 70 C, and the ambient temperature should be -5 to 50 C. Operation under low temperature (5 C or less) leads to cause damage or operation failure due to frozen moist in the fluid or air. Protection against freezing is necessary. Air dryer is recommended for elimination of drain and water.

PD measurement value The upper and lower limit values of the rated pressure value can be output compulsively as PD measurement value (process data). Press the UP or DOWN button to select the lower or upper limit value. : IO-Link mode can provide the communication function. : Refer to page 62 for details of the PD measurement value.

Relationship between flow rate and PD -37No.PF-OMX0007-A Conversion formula of the process data and flow measurement value (1) Conversion formula from the process data to the flow measurement value: Pr = a (PD) + b (2) Conversion formula from the flow gauge measurement value to the process data: (PD) = (Pr b) / a Pr: Flow measurement value and pressure set value PD: Flow measurement value

The operating fluid temperature range is -5 to 70 C, and ambient temperature range is -5 to 50 C. Operation under low temperature (5 C or less) leads to cause damage or operation failure due to frozen moist in the fluid or air. Protection against freezing is necessary. Air dryer is recommended for elimination of drain and water.

0 1.6000 -0.105 1.680 kPa 0 1,600.0 -105 1680 Kgf/cm 2 0 16.315 -1.07 17.13 ISE71 Bar 0 16.000 -1.05 16.80 Psi 0 232.06 -15.2 243.7 (PD) 1000 5000 738 5200 ISE70 MPa (PD) PD [MPa] (PD)(ISE70 MPa) -62No.PS-OMV0003CN-G Pr = a (PD) + b (PD) = (Pr b) / a Pr PD a b [] a b MPa 0.00025 -0.25 kPa 0.25 -250 kgf/cm 2 0.002549 -2.549 ISE70 bar 0.0025 -2.5 psi 0.03626 -36.26 MPa 0.0004

F (LC6D-2 only) +24V GND CW+ CW CCW+ CCW PD+ PD A B C D E 7 6 3 10 CW CW 10 10 2 R 330 CCW input 330 CCW input 2 2 9 1 CCW CCW 8 9 9 5 4 14 13 12 R 330 PD input 1 PD 8 11 F Functions Function change-over switch Input signal terminal CW pulse input terminal By applying the pulse input, the actuator moves from the motor side to the end side.

F (LC6D-2 only) +24V GND CW+ CW CCW+ CCW PD+ PD A B C D E 7 6 3 10 CW CW 10 10 2 R 330 CCW input 330 CCW input 2 2 9 1 CCW CCW 8 9 9 5 4 14 13 12 R 330 PD input 1 PD 8 11 F Functions Function change-over switch Input signal terminal CW pulse input terminal By applying the pulse input, the actuator moves from the motor side to the end side.

0 1450.4 -73 1523 (PD) 1000 5000 800 5200 MPa 0 16.000 -0.80 16.80 kgf/cm 2 0 163.15 -8.2 171.3 bar 0 160.00 -8.0 168.0 ISE78G psi 0 2320.6 -116 2437 (PD) 1000 5000 800 5200 ISE70G MPa (PD) PD [MPa] (PD)(ISE70G MPa) -65No.PS-OMV0008CN-E Pr = a (PD) + b (PD) = (Pr b) / a Pr PD a b [] a b MPa 0.00025 -0.25 kPa 0.25 -250 kgf/cm 2 0.00254925 -2.54925 ISE70G bar 0.0025 -2.5