x 0.8 Mixed C4 C6 M5 M 1 2 3 4 5 5 6 24VDC 12VDC Match to the voltage specifications of the manifold.
[ ] for AC Grommet (G), (H): SYJ34G H -M5 M5 x 0.8 (A port) 14 5 10 2-3.2 (For mounting) 26.4 17 3 2.5 Manual override A 11 G: Approx. 300 H: Approx. 600 (Lead wire length) 48.6 [50.8] (Light/surge voltage suppressor) 41.5 [48.5] + M5 x 0.8 (X port) 35.6 28.5 26.1 X R P 13 5 5 10 M5 x 0.8 (P, R port) 10 8.6 7.5 17.5 23 L plug connector (L): SYJ34-L-M5 M plug connector (M): SYJ34-M-M5 M8
: M-5P) 30 4-M6 x 1 4-M5 x 0.8, depth 7 Bottom hole diameter 5.1 W 32 0.05 D B 8 0.05 47 13 Operating port 2-M5 x 0.8 J 8 Mounting base side B D 16.5 14.5 Across AA MXP16-30B Without magnet and switch rail 2-M3 x 0.5, depth 3.5 For rail mounting 8 2-M2 x 0.4, depth 3 For magnet mounting 8.5 10.7 6-M5 x 0.8, depth 7 20 20 L (mm) Model M MA W H S Z J V K L MXP16-20B 40 30 65 58 20 102 93 82
L plug connector (L) (Made to order) 100V AC 200V AC 110V AC 220V AC 0.6 0.7 M plug connector (M) (A) 2 1 (P) 3 (R) M plug connector (M) N.O.
min (ANR) 450 L/min (ANR) 1100 L/min (ANR) [AFD] 120 L/min (ANR) 240 L/min (ANR) 600 L/min (ANR) Nominal filtration rating*2 [AFM] 0.3 m (99.9% filtered particle size) [AFD] 0.01 m (99.9% filtered particle size) Outlet side oil mist concentration*3, *4 [AFM] Max. 1.0 mg/m3 ( 0.8 ppm) [AFD] Max. 0.1 mg/m3 (Before saturated with oil 0.01 mg/m3 or less 0.008 ppm) Compressed air purity class
7 None Blue 8 White Purple Triangle mark position 6 Red 9 Black Gray 10 Black White 26 2 25 1 11 Red White W 12 Red Yellow 13 Red Orange 14 Black Yellow (15.6) Terminal no. 15 Black Pink L 16 White Blue 17 None Purple Flat Ribbon Cable Assembly 18 None Gray Cable length (L) 26 pins 20 pins 10 pins 19 Black Orange 1.5 m AXT100-FC26-1 AXT100-FC10-1 AXT100-FC20-1 20 White Red 3 m AXT100-FC26
type (0.6 m) L type (1.5 m) L type (3 m) S6m type (EX600)*4 SAm type (EX245)*4 Sm type (EX250)*4 Sm type (EX260) S3m type (EX120) 680 471 404 514 698 829 520 448 367 689 480 413 523 707 838 529 457 367 709 500 433 543 727 858 935 549 477 391 914 705 638 748 932 1063 1100 754 682 568 *1 Weight: W is the value for the internal pilot specification, the max. fitting size, and the manifold
M M A L1 H/DL L/LL D1 D2 L2 KC H Connection threads KK Male Branch: KPQU, KPGU (M5) KK130 Effective area mm2 D Model L TPH TPS A (M5) 2 x Applicable tubing Connection thread R M H (width across flats) Note1) Applicable tubing O.D. mm Weight g P M P DM D M5 x 0.8 1/8 1/4 M5 x 0.8 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 KPGU04-M5 KPGU04-01 KPGU04-02 KPGU06-M5 KPGU06-01 KPGU06-02 KPGU08-01 KPGU08-02
(-F2) G H 22.5 28.5 [35.5] A, B port M5 x 0.8 28.5 [35.5] 2 23.5 25 18.5 P 16.9 (15) EA EB M5 x 0.8 (P, EA, EB port) For manifold gasket positioning 21.5 die-cast hole 19 22.5 L plug connector (L): SY3120-L(-F ) M plug connector (M): SY3120-M(-F ) C4, N3 C6, N7 M8 connector (W0): SY3120-W0(-F ) 1 2 1 2 C4, N3 C6, N7 C4, N3 C6, N7 1 2 28.5 [35.5] 13.1 (Lead wire length) 33 M8 x 1 Approx. 300
End boss type One-touch fitting K End boss type with M5 port M Specifications Flat finger type 10, 16, 20, 25 Double acting, Single acting (normally open, normally closed) Air Type Cylinder bore Action Fluid Dimensions 4-MM thread depth L Attachment mounting threads A D G D W B B A C S O Unit: mm C D MM L W G Open Closed B Model A MHQG2 compatible MHQ2 compatible MHQG2 compatible MHQ2 compatible
L D-A73 (Example) RS H A Lead wire length RZQ 5 m None Nil L 0.5 m 3 m Z N MI W S Applicable for the connector type (D-C) only.
The spacing (L) of the intermediate supports must be no more than the values shown in the following graph. 25 LEMH32 20 Load mass m [kg] LEF m 15 LEJ LEMH25 L 10 LEL 5 LEM LEM m 0 0 200 400 600 800 1000 1200 1400 L LEY Support spacing L [mm] m LES 25 LEPY LEPS L L LEMHT32 20 Load mass m [kg] LER 15 LEH LEMHT25 m m 10 LEY -X5 L 5 11LEFS 0 0 200 400 600 800 1000 1200 1400 11LEJS Square nuts
Load weight (kg) Caution The cylinder should be mounted in m1 orientation if maximum dustproofing is required. m m m Moment (Nm) M = F x L F3 M = F x L M = F x L F F2 L2 L1 L3 Maximum load weight Select the load weight from within the range of limits shown in the graphs. Note that the maximum allowable moment value may sometimes exceed even the operating limits shown in the graphs.
(inch) Connection thread M R Model H (Width across flats) L A M Min. port size KQ2H01-M5 KQ2H07-M5 KQ2H01-M5
Model *1) * A B C D E E1 F G H K L M N J P Q MGF MXS 8 MXS12 MXS16 MXS20 MXS25 MXS-BT 8 38 23 12.5 14 40.8 5 8 12 1.4 16.6 7 15.5 14.6 M8 X 1 M3 X 12 M3 X 16 MXS-BT12 45 31 18 14 40.8 6 8 12 1.4 20.5 10 15 18.5 M8 X 1 M4 X 8 M4 X 15 CY1 MXS-BT16 55 37 23.5 16 46.7 7 10 14 1.4 23 12 18.5 21 M10 X 1 M5 X 10 M5 X 18 MXS-BT20 70 47 29 23 67.3 11 12 19 12 27 13 25.5 25 M14 X 1.5 M5 X 12 M6 X 25