XL-25 XL-40 XL-50 XL-63 AC90240V Ass'y XLA25-60S-1 XLA25-60S-1 XLA25-60S-2 Ass'y 1 1 1 H4 AC100V 200/40 200/50 400/100 / AC200V 800/40 800/50 800/100 Ass'y XLA25-60S-1 XLA25-60S-2 XLA25-60S-2 XLA25-60S-3 Ass'y 1 1 1 1 H5 AC100V 200/40 400/70 400/80 600/130 / AC200V 800/40 1600/80 1600/80 2400/130 XL-80 XL-100 XL-160 AC90240V Ass'y XLA25-60S-3 XLA25-60S-2 XLA25-60S-2 Ass'y
fluid outlet 0.6 60 Pressure [MPa] 0.5 50 Lifting head [m] Usable flow rate range 0.4 40 0.3 30 Circulating fluid return 0.2 20 0.1 10 0 0 0 20 40 60 80 100 120 140 160 180 Circulating fluid flow[L/min] Fig. 8-11 Pump capacity(HRL300-A-20 CH1) 8.5.4 HRL-A-20CH2 0.6 60 0.5 50 Lifting head [m] Pressure [MPa] 0.4 40 Usable flow rate range Circulating fluid outlet 0.3 30 0.2 20 Chiller display
Max acceleration/deceleration [mm/s2] Positioning repeatability [mm] 0.01 Lost motion[mm] Note3) 0.05 Lead [mm] 20 12 6 24 16 8 30 20 10 Impact/Vibration resistance [m/s2] Note4) 50/20 Actuation type Ball screw (LEKFS)Ball screw + Belt (LEKFSR/L) Guide type Linear guide Operating temperature [] 5 to 40 Operating humidity [%RH] 90 or less(No condensation) Motor output [W]/size [mm] 100W/40
Pin description Load is an analog input equipment such as a voltmeter, ammeter. 1 DC(+) PF2A7H-(-M) 68 69 2 Analog output 3 DC() Accumulated pulse output wiring examples 4 OUT1 4-I thread with depth J 40 Max. 30 V 80 mA or less OUT1 Load Black H 0 V or Blue 50 msec 50 msec PF2A7H-(-M) 28 29 A B C D E F G H I J Model Brown PF2A703H PF2A706H PF2A712H 55 160 40 92 67 55 Rc1, NPT1, G1 36 M5 x
According to d = 40, E2 is obtained. Weight equivalent to impact object Me (kg) 0.628 1.10 1.26 1.34 2.04 5.
Example) 10-ARP30K-03BE-1RY Clean room compliant, copperfree, fluorine-free, silicon-free Clean room compliant Copper-free, fluorine-free Symbol 20 30 40 Body size Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without
Table 3.3-1 Power supply cable and earth leakage breaker (Recommended) Earth leakage breaker Terminal Power Recommended Cable Sensitivity block Model supply crimp Specifications Breaker of screw voltage terminal 1 size leakage diameter (A) current (mA) 4 cores x AWG10 (4 cores x 5.5 mm2) HRL100-A-20 3-phase R5.5-5 30 200V AC including (50Hz) ground M5 30 4 cores x 3-phase HRL200-A-20 40 AWG8
Mounting bolt X T MM L H D B RB08-X331 RB10-X331 RB14-X331 RB20-X331 RB27-X331 15 4.5 drill, 8 counterbore depth 4.4 32 M8 x 1.0 10 20 M4 7.5 5.5 drill, 9.5 counterbore depth 5.4 19 40 M10 x 1.0 12 25 M5 9.5 9 drill, 14 counterbore depth 8.6 25 54 M14 x 1.5 16 34 M8 12.5 11 drill, 17.5 counterbore depth 10.8 38 70 M20 x 1.5 22 44 M10 19 13.5 drill, 20 counterbore depth 13 50 80 M27 x 1.5
Heater specifications Item XL-25 XL-40 Rated voltage of the heater 90 to 240 ACV Heater assembly number XLA25-60S-1 No. of heater assemblies 1 pc. H 4 S y m b o l consumption (W) 100 VAC 200/40 Initial power / Power 200 VAC 800/40 Heater assembly number XLA25-60S-1 XLA25-60S-2 No. of heater assemblies 1 pc. 1 pc.
40 100 50 30 30 20 20 50 25 10 10 0 0 0 0.1 0.2 0.3 0.4 0.5 0.6 1.0 2.0 3.0 4.0 5.0 6.0 Supply pressure [MPa] Supply pressure [MPa] Flow rate Characteristics Flow rate characteristics Supply pressure: 0.4MPa Supply pressure: 0.4MPa 100 90 100 90 Vacuum pressure [kPa] Vacuum pressure [kPa] 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 10 20 30 40 50 60 70 80 90 100 110 120 20 60 100
Station L1 L2 2 110 3 145 36 4 180 71 5 215 106 6 250 141 Unit Manifold With DIN rail Deflection level indicator Terminal block box 35 40 L1 Deflection level indicator 75 40 Terminal block box Rc1/8 SUP. 25 DIN rail center 70 (94.4) 90 25 (94.4) SUP 70 4.5 90 40 (4.5) 30 4.5 Adjusting knob Gauge Electrical entry Applicable O.D. 6.5 to 8.5 12 L2 L3 Gauge 105 Electrical entry Applicable O.D
pressure: 0.4 MPa 100 90 100 90 ZQ Vacuum pressure (kPa) Vacuum pressure (kPa) 80 80 70 70 ZF 60 60 50 50 ZP 40 40 30 30 ZCU 20 20 10 10 AMJ 0 0 10 20 30 40 50 60 70 80 90 100 110 120 20 60 100 140 180 220 260 300 130 Suction flow rate (/min(ANR)) Suction flow rate (/min(ANR)) Misc.
P 46 46 38 PP 70 50 M12 x 1.75 M10 x 1.5 M8 x 1.25 N H GA C M6 M6 M5 18.5 KA KB 100 63 30, 50, 75, 100 40 78 73 58 66.5 61.5 48.5 4 4 3.5 8 100 90 120 160 1/8 1/8 1/8 8 200 160 20 20 11.5 11.5 9.5 846 Guide Table 10-MGF Specific Product Precautions Be sure to read this before handling.
Description Size 1 Valve Rc1/2 2 Valve Rc1 3 Y-strainer (#40) Rc1 4 Flow metter Prepare a flow metter with an appropriate flow range. 5 Valve (Part of thermo-chiller) Rc3/4 6 Y-strainer (#40) Rc1/2 3.4 Piping HRS Series 3-28 HRX-OM-W032 Chapter 3 Transport and Setting Up 3.5 Circulating Fluid Supply 3.5.1 Automatic water fill function When clear water is used, refer to 7.1 Quality Control
8 22 8 15 80 18 M6 x 1 20 40 36 M26 x 1.5 124 13 10 70 41 41.6 3 16 11 29 10 16 92 23 M6 x 1 26 50 46 M32 x 2 150 13 TF TN Nil P (Piping port) ZZ X W TT Model 12-REA25 12-REA32 12-REA40 50 Rc1/8 30 NPT1/8 137 G1/8 17 50 Rc1/8 40 NPT1/8 156 G1/8 19 60 Rc1/4 40 NPT1/4 182 G1/4 22 12-REA50/63 0 L0.2 33 B 2 x 4 x V Effective thread depth 16 2 x P (Piping port) 14 14 8 (R) D X Q Q 14.5 22 I 2
thread depth J 2-Port size D I NB NB T N K W N S + Stroke F F NA R ZZ + Stroke 43 35 29 22 20.5 27.8 D Model Port size K NN B L MM x J N NA H 16 15 10 I 46 36 30 NB 19 17 17 T S 11 9 8 G ZZ 10 8 8 R 60 50 50 W 16 16 13 F 40 40 30 X 12-REA40 12-REA32 12-REA25 Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/4 70 60 46 M26 x 1.5 M26 x 1.5 M32 x 2.0 21 17 15 50 40 34 19 15 13 150 124 111 182 156
Specifications AP3600 AP3625 AP3650 AP3657 Operating Parameters Gas Operating pressure Proof pressure Burst pressure Ambient and operating temperature Cv Select compatible materials of construction for the gas Vacuum to 3000 psig (20.7 MPa) 4000 psig (27.6 MPa) 8000 psig (55.2 MPa) 40 to 160F (40 to 71C) (No freezing) 1) 0.29 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 2) 4 x 10-9 Pam3/sec 2) Ra
Item Default setting PF3W7##-L Lock ring Without units selection function Display OUT1 set value OUT1 hysteresis OUT2 hysteresis Bottom value OUT2 set value Peak value [ Unit] Display unit setting [ L] L/min, oC Bracket mounting (PF3W711) Mount the product (with bracket) using the mounting screws supplied (M5 x 4 pcs.).
DC (+) 1 NC 2 DC () 3 4 OUT 4 43 2-3.4 Flow direction PFA511/521/551 62 116 23 1.6 76.2 54 44 34 44.5 2-Port size 30 40 50 (43.5) 42 6 Flow direction 9 Series PFA Dimensions/Remote Type Display Unit for Air PFA3-A Panel mount type Internal circuit and wiring examples to are terminal numbers. 41.8 40.3 Sensor 4.3 40 Blue Brown Black N.C. 1 2 3 4 SMC FLOW SWITCH 5 6 7 8 OUT1 OUT2 35.8 A 40
Temperature conditions Water (Standard) Air (Standard) Oil (Standard) Vacuum (3) (V, M) Maximum Minimum 40 1 60 5(1) 40 5 40 40 5 5(2) Pilot port Note 1) Dew point: 5C or less Note 2) 500 cSt or less Note 3) V, M in parentheses are option symbols.